Electrical Wiring Residential
19th Edition
ISBN: 9781337101837
Author: Ray C. Mullin, Phil Simmons
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 6, Problem 13R
To determine
Choose the correct option from the given choices that will be the replacement receptacle when the old receptacle is removed from residential wiring.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
ladder diagram for bottom half of a switched receptacle is to always be hot plus a duplex receptacle that is controlled from two locations using a coast 3-way wiring system
ladder diagram for bottom half of a switched receptacle is to always be hot plus a duplex receptacle that is controlled from two locations using a coast 3-way wiring system multiwire circuit
QUESTION 9
When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true?
a
A.This would be approved by code as the gas pipe is only being bonded to the electrical system.
b
B.This installation would be approved by code, as the gas pipe is not a grounding electrode.
c
C.Both A and B
d
D.Neither A nor B
Chapter 6 Solutions
Electrical Wiring Residential
Ch. 6 - Explain the operation of a ground-fault circuit...Ch. 6 - Prob. 2RCh. 6 - Where must GFCI receptacles be installed in...Ch. 6 - Prob. 4RCh. 6 - Prob. 5RCh. 6 - A homeowner calls in an electrical contractor to...Ch. 6 - Prob. 7RCh. 6 - Extremely long circuit runs connected to a GFCI...Ch. 6 - If a person comes in contact with the hot and...Ch. 6 - What might happen if the line and load connections...
Ch. 6 - Is a GFCI receptacle permitted be installed as a...Ch. 6 - Prob. 12RCh. 6 - Prob. 13RCh. 6 - Prob. 14RCh. 6 - Prob. 15RCh. 6 - Construction sites can be dangerous because of the...Ch. 6 - Prob. 17RCh. 6 - Prob. 18RCh. 6 - The term SPD is becoming quite common. What do the...Ch. 6 - Transients (surges) on a line can cause spikes or...Ch. 6 - Prob. 21RCh. 6 - Prob. 22RCh. 6 - Some line transients are not damaging to...Ch. 6 - Briefly explain the operation of an immersion...Ch. 6 - What range of leakage current must trip an IDCI?Ch. 6 - Prob. 26RCh. 6 - Other than for a few exceptions, the NEC requires...Ch. 6 - In an old house, an existing nongrounding...Ch. 6 - Prob. 29RCh. 6 - NEC 210.12(A) requires AFCI protection for the...Ch. 6 - When installing GFCI and AFCI circuit breakers in...Ch. 6 - Prob. 32RCh. 6 - Prob. 33RCh. 6 - A switch that is located inside a bedroom for an...Ch. 6 - Which of the following installations for a kitchen...Ch. 6 - The receptacle outlets in the garage are required...Ch. 6 - Two 125-volt receptacles on a 20-ampere, 120-volt...Ch. 6 - Prob. 38R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwarda. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardAn electrician is installing switches and receptacles in a house where the wall and ceiling coverings are installed. She knows that one end of a two-wire Type NM cable is in Box A but does not know whether the other end is in Box B or Box C. Using the procedure for using a continuity tester outlined at the end of Chapter 4 in the textbook as a guide, explain how she could use the continuity tester to determine which box contains the other end of the cablearrow_forward
- For residential wiring, not less than one 15-ampere lighting branch circuit should be provided for every ____________ ft2 of floor area. If 20-ampere lighting branch circuits are used, provide one 20-ampere lighting branch circuit for every ____________ ft2 of floor areaarrow_forwardIn order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector red tagged (turned down) the installation. Who is rightthe homeowner or the electrical inspector? Explain. ___________________ ___________________ ___________________arrow_forwardWhen calculating a dwelling lighting load on the "volt-ampere per ft" basis, the receptacle load used for floor lamps, table lamps, and so forth arearrow_forward
- In order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector? Explain.arrow_forward5. If a separate, wire-type equipment grounding conductor (EGC) is used for any reason, the EGC of a grounding-type receptacle must be connected to which of the following?A. The grounding terminal bar outside the service equipment enclosure in a grounded systemB. An EGC that's part of another branch circuit that originates from where the branch circuit for the receptacle originatesC. Any accessible point on the grounding electrode conductorD. The service conductor outside the service equipment enclosure in an ungrounded systemarrow_forwardan office building has an area of 36,000 sqft, and the number of receptacles is unknown. How many 2-wire, 20-ampere, 120-volt circuits do you need to plan for to supply both the lighting loads and the receptacles?arrow_forward
- What color are the faceplates in the bathrooms? Refer to the specifications. ________________arrow_forwardWhich of the following installations for a kitchen waste disposal that operates on a 15-ampere, 120-volt branch circuit requires AFCI protection? (Circle the correct answer.) a. The disposal operates by a switch that is installed above the kitchen counter. b. The disposal operates by a switch that is installed under the counter next to the disposal. c. Both (a) and (b) d. Neither (a) nor (b).arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning