Fundamentals of Electromagnetics with Engineering Applications
5th Edition
ISBN: 9780471263555
Author: Stuart M. Wentworth
Publisher: John Wiley & Sons
expand_more
expand_more
format_list_bulleted
Question
Chapter 6, Problem 6.21P
(a)
To determine
The location of load impedance
(b)
To determine
The location of load impedance
(c)
To determine
The location of load impedance
(d)
To determine
The location of load impedance
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A 3-phase, 420 kV transmission line consists of 1·5 cm radius conductor spaced 2 meters apart in equilateral triangular formation. If the dielectric strength of air is 30 kV (max) per cm and corona loss per km of the line is 146.91kW/phase. Take air density factor ∂= 0·952 Estimate:
i. irregularity factor
ii. comment on type of conductors
please help me dont copy from google
In a 250 km long, interphase voltage of 154 kV, 50 Hz three-phase transmission line, the diameter of the steel core aluminum conductors is 22 mm, the roughness coefficient of the conductors is 0.8, and the spacing between the phases is 4 m. Average air temperature along the line is 27 degrees, air pressure is 750 mm Hg. Calculate the total corona loss per phase at 1.5 times the operating voltage under these conditions (E0=21.2 kV/cm)
the air-filled two-wire line has a characteristic impedance of 50 Ω and is operated at f = 3GHz .the load is ZL= 100 +j40Ω . for the line above, calculation ZL on the chart the line impedance 2.5 cm from the load , the admittance, the VSWR on the line, and distance from the load to the first voltage minimum and maximum.
Chapter 6 Solutions
Fundamentals of Electromagnetics with Engineering Applications
Ch. 6 - Prob. 6.1PCh. 6 - Prob. 6.2PCh. 6 - Modify (6.3) to include internal inductance of the...Ch. 6 - Prob. 6.5PCh. 6 - The specifications for RG-214 coaxial cable are as...Ch. 6 - For the RG-214 coax of Problem 6.6 operating at...Ch. 6 - If 1.0 W of power is inserted into a coaxial...Ch. 6 - Starting with a 1 .0-mm-diameter solid copper...Ch. 6 - A coaxial cable has a solid copper inner conductor...Ch. 6 - Prob. 6.11P
Ch. 6 - Prob. 6.12PCh. 6 - Prob. 6.13PCh. 6 - A source with 50- source impedance drives a 50-...Ch. 6 - Prob. 6.15PCh. 6 - Prob. 6.16PCh. 6 - The input impedance for a 30.-cm length of...Ch. 6 - For the lossless T-line circuit shown in Figure...Ch. 6 - Prob. 6.19PCh. 6 - Prob. 6.20PCh. 6 - Prob. 6.21PCh. 6 - Repeat Problem 6.14 using the Smith Chart.Ch. 6 - Prob. 6.23PCh. 6 - Prob. 6.24PCh. 6 - Prob. 6.25PCh. 6 - On a 50- lossless T-line, the VSWR is measured as...Ch. 6 - Prob. 6.27PCh. 6 - Prob. 6.28PCh. 6 - Referring to Figure 6.20, suppose we measure...Ch. 6 - A matching network, using a reactive element in...Ch. 6 - A matching network consists of a length of T-line...Ch. 6 - You would like to match a 170- load to a 50-...Ch. 6 - A load impedance ZL=200+j160 is to be matched to a...Ch. 6 - Repeat Problem 6.34 for an open-ended shunt-stub...Ch. 6 - A load impedance ZL=25+j90 is to be matched to a...Ch. 6 - Repeat Problem 6.36 for an open-ended shunt-stub...Ch. 6 - Prob. 6.38PCh. 6 - Prob. 6.39PCh. 6 - Prob. 6.40PCh. 6 - Prob. 6.41PCh. 6 - Prob. 6.42PCh. 6 - Prob. 6.43PCh. 6 - Prob. 6.44PCh. 6 - Prob. 6.45PCh. 6 - Prob. 6.46PCh. 6 - The top-down view of a microstrip circuit is shown...Ch. 6 - Prob. 6.48PCh. 6 - Prob. 6.49PCh. 6 - Prob. 6.50PCh. 6 - Prob. 6.51PCh. 6 - Prob. 6.53PCh. 6 - Prob. 6.54PCh. 6 - Prob. 6.55PCh. 6 - Prob. 6.56PCh. 6 - Prob. 6.57PCh. 6 - Actual pulses have some slope to the leading and...Ch. 6 - Prob. 6.59P
Knowledge Booster
Similar questions
- A 30 mile, 3-phase transmission line delivers 8,000 kW at 33 kV, p.f. 0.8 lagging. The resistance and reactance of single conductor are 0.6 ohm and 0.72 ohm respectively per mile. Find the voltage at the sending end in kV.arrow_forwardA 3-phase transposed line has conductors of diameter 2 cm and spaced at distance of 3.65, 5.5and 8.2 m between the centres. Calculate the inductance per phase per km of line length.[1.31 mh]arrow_forwardIn a 250 km long, interphase voltage of 154 kV, 50 Hz three-phase transmission line, the diameter of steel core aluminum conductors is 22 mm, the roughness coefficient of the conductors is 0.8, and the spacing between phases is 4 m. Average air temperature along the line is 27 degrees, air pressure is 750 mmHg. Calculate the total corona loss per phase at 1.5 times the operating voltage under these conditions (E0=21.2 kV/cm)arrow_forward
- At a frequency of 1 kHz the primary constants of a transmission line are resistance R = 25 /loop km, inductance L = 5 mH/loop km, capacitance C = 0.04µF/km and conductance G = 80 µS/km. Determine for the line the characteristic impedance, the propagation coefficient, the attenuation coefficient and the phase-shift coefficientarrow_forwardA shielded, twin-wire line has a dielectric of relative permittivity 2 and acharacteristic impedance of 50 ohms. Calculate the phase velocity forsignal propagation along the line, and hence L and C.arrow_forwardA three-phase line at 60 Hz is 300 miles long. The voltage at the transmitting end is 230 kV. The parameters of the line are R= 0.2 Ω /mi, x=0.6Ω/mi y=5.5 µS/mi. a) Show the equivalent pi-diagram with all its values considering the line without losses. losses. Present the values of intermediate calculations. b) Determine the ratio of maximum power to CIL if the line operates at 230 KV.arrow_forward
- 3-phase line has conductors 4 cm in diameter spaced equilaterally 2 m apart. If the dielectric strength of air is 29 kV (max) per cm, find the disruptive critical voltage for the line. Take air density factor =0.952 and irregularity factor mo = 0.9.arrow_forwardA single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight meter. Determine 1)The capacitance in uF/km without effect of ground 2)The capacitance in uF/km with effect of groundarrow_forwardA 3-phase, 50 Hz, 100 km transmission line has the following constants ;Resistance/phase/km = 0·1 ΩReactance/phase/km = 0·5 ΩSusceptance/phase/km = 10−5siemenIf the line supplies a load of 20 MW at 0·9 p.f. lagging at 66 kV at the receiving end, calculate by usingnominal π method :arrow_forward
- Line parameters of the 50 km long 34.5 kV medium voltage distribution network supply line are under 80 kW, Coso = 0.8 reverse Load; a) Draw the equivalent circuit used in modeling the transmission line. b) Draw the phasor diagram of this transmission line. c) Calculate the per line voltage value. Note: According to the length of the line, leakage permeability and capacitance values will be neglected.arrow_forwardIf characteristic impedance Z,= 50-j302, propagation constanty= 0.6+ j3.5/m, and the length = 1 m. The line is short circuited at the load end, Vg 10 V, Zg = 3+jS Find: a) Input impedance Z. b) Voltage reflection coefficient at load side. c) Voltage and current on the middle of transmission line.arrow_forwardhe parameters of the 500km long transmission line are impedance z = 0.1 + j * 0.4ohm / km and admintance Y = j * 4.2 Siemens / km. At the end of the line, 988.1A current is drawn under 400kV voltage between phases. The angle of the current is -68.6 degrees. In which option the characteristic impedance value of the long transmission line is given correctly. a) 400 + j * 0 b) 441,23-j * 25,7520 c) 0 + j * 400 d) 401,23-j * 250 e) 310,97-j * 38,282arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,