Chapter 9, Problem 4Q
Interpretation Introduction
Interpretation:
The importance to allow the liquid level in the column to drop to the level of alumina before the solution of the compound is separated should be explained.
Concept introduction:
A separation technique used for the segregation of components of chemical mixture based on the difference between the adsorption of different components in stationary and mobile phase is called column chromatography.
It is used for purification or segregation of compounds. It consists of two phases namely:
- Stationary phase (solid)
- Mobile phase (generally liquid)
Silica gel is commonly used as the stationary phase.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Can paper chromatography be used to separate and identify very volatile substances? Why? Please explain comprehensively.
what is chromatography? Explain different types of chromatography and explain how to seperate compounds. indicate stationary phase mobile phase.
Write the advantages and disadvantages of Liquid chromatography compared with Gas chromatography.
Chapter 9 Solutions
MACROSCALE+MICRO.ORG...-OWLV2 ACCESS
Knowledge Booster
Similar questions
- Describe chromatography analysis, the two essential phases used in paper chromatography and provide an example.arrow_forward[1] In paper chromatography, why do some ions move only a short distance from the point of application while others move much more?arrow_forward_is a technique which is used to separate a single chemical 3. compound from a mixture dissolved in a fluid. * Paper Chromatography Thin Layer Chromatography O Column Chromatographyarrow_forward
- In color chromatography of plant pigments, what complications would a dried-out column (solvent level is below the top of the silica) introduce to the elution and isolation of pigments?arrow_forwardYou are carrying out an experiment by analysing alcoholic drinks by gas chromatography. Why is Gas chromatography the best technique used for this analysis? Why is Carbowax a suitable stationary phase for this analysis? What gases are used and what is their purpose and source?arrow_forwardCan you use chromatography to purify a mixture? Why?arrow_forward
- What is the purpose of adding two drops of acetic acid in thin layer chromatography of plant pigment? What would be the effect of the following errors in chromatographic work? - a) The solvent level in the developing chamber is higher than the spotted sample. - b) Too much sample is applied to the paper. - c) The paper is allowed to remain in the chamber after the solvent front has reached the top of the plate.arrow_forwardIn tabulated form, write the common characteristics, advantages, and disadvantages of paper chromatography, thin layer chromatography, and column chromatographyarrow_forward2. A chromatographic column is eluted with a solution containing a mixture of two components, X and Y. The chemical affinity of X for the stationary phase is less than that of Y and the chemical affinity for X for the mobile is greater than that of Y. Which substance will be eluted first? Explain your answer.arrow_forward
- Column chromatography is also very useful for separating mixtures of organic compounds that are not coloured. Briefly explain how you could use column chromatography for the separation of a colourless mixture, and how you could identify your separated compounds.arrow_forwardexplain what a response ratio is in Gas Chromatography and why it might be needed to quantify compounds in a mixture?arrow_forwardOne method for the quantitative determination of the concentration of constituents in a sample analyzed by gas chromatography is area normalization. Here, complete elution of all the sample constituents is necessary. The area of each peak is then measured and corrected for differences in detector response to the different eluates. This correction involves dividing the area by an empirically determined correction factor. The concentration of the analyte is found from the ratio of its corrected area to the total corrected area of all peaks. For a chromatogram containing three peaks, the relative areas were found to be 16.4, 45.2 and 30.2, in order of increasing retention time. Calculate the percentage of each compound if the relative detector responses were 0.60, 0.78 and 0.88, respectively.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Macroscale and Microscale Organic ExperimentsChemistryISBN:9781305577190Author:Kenneth L. Williamson, Katherine M. MastersPublisher:Brooks ColePrinciples of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Macroscale and Microscale Organic Experiments
Chemistry
ISBN:9781305577190
Author:Kenneth L. Williamson, Katherine M. Masters
Publisher:Brooks Cole
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning