Question
Chapter 9, Problem 9.19QAP
Interpretation Introduction
Interpretation:
The physical effects and interferences that the method of standard additions would correct or compensate for in AAS should be described.
Concept introduction:
Standard addition is a method which is referred to as the technique of quantitative analysis to lower the effects of the matrix interfering in the signals of analyte measurement. Interference is a type of phenomenon which leads to fluctuations in the intensity of the signals of analyte measurements in spectroscopy.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Explain why an internal standard is required during sample preparation in quantitative analysis when using atomic spectroscopy?
i) Find the differences between the AES and XPS in terms of principle and information obtained from the spectra.
ii) Why AFM is mostly utilized microscopic method for the determination of the thickness of the film?
Briefly compare the advantages and disadvantages of Nujol mulls and KBr pellets for the analysis of solid samples by IR spectrometry.
Chapter 9 Solutions
PRINCIPLES OF INSTRUMENTAL ANALYSIS
Ch. 9 - Prob. 9.1QAPCh. 9 - Prob. 9.2QAPCh. 9 - Why is an electrothermal atomizer more sensitive...Ch. 9 - Prob. 9.4QAPCh. 9 - Prob. 9.5QAPCh. 9 - Prob. 9.6QAPCh. 9 - Prob. 9.7QAPCh. 9 - Prob. 9.8QAPCh. 9 - Prob. 9.9QAPCh. 9 - Prob. 9.10QAP
Ch. 9 - Prob. 9.11QAPCh. 9 - Prob. 9.12QAPCh. 9 - Prob. 9.13QAPCh. 9 - Prob. 9.14QAPCh. 9 - Prob. 9.15QAPCh. 9 - Prob. 9.16QAPCh. 9 - Prob. 9.17QAPCh. 9 - In the concentration range of 1 to 100 g/mL P,...Ch. 9 - Prob. 9.19QAPCh. 9 - Prob. 9.20QAPCh. 9 - Prob. 9.21QAPCh. 9 - The chromium in an aqueous sample was determined...Ch. 9 - Prob. 9.23QAP
Knowledge Booster
Similar questions
- Induction coupled plasma (ICP) emission spectrometry is widely used for the sensitive multi-element determinations. How does the ICP work?arrow_forward4. When plotting a standard curve in absorption spectrophotometry, one uses Abs values instead of %T values. Explain why you need to use Abs values instead of %T values when constructing a standard curve (or a linear Beer's law Plot)arrow_forwardWhat are the advantages of using the KBr in IR spectroscopic sample preparation? Please shortly write at your own words. (4-5 lines maximum ).arrow_forward
- (2) Why it is important to measure the absorbance in the range of 0.4 to 0.9. Explain your Answer. (3) Write short notes on Acid Rain and its Hazards with proper chemical reactions.arrow_forward6 Why standard solutions are used in Atomic absorption Spectroscopy (AAS) whereas UV-Vis molecular absorbance only extinction coefficient is necessary?arrow_forward5 What would the effect of increasing sample pressure (while maintaining a fixed cell length) have on an FTIR spectrum. By ”cell” I mean the chamber holding the gas.arrow_forward
- Flame Atomic Absorption Spectroscopy (FAAS) method is selected due to its wide applicability for metal ion analysis in drinking water samples. Discuss how can we determine the concentration of selected heavy metals (Cu and Cr) in the unknown tap water sample.arrow_forwardWhich of the following statement is incorrect? The quality of grating of the monochromator affects the resolution of two closely spaced wavelengths in a spectrum. OICP (Inductively coupled plasma) is commonly used in atomic emission spectrometry. Cuvette is generally used for atomic absorption spectrometry (AAS) as the sample cell. The measurement in fluorescence spectrometry is generally more sensitive than absorption spectrometry.arrow_forwardHow do I solve for [FeSCN2+] heres the formula they provided me and my data but I would like steps on how to solve it and what data I should be using to solve for it u can use any fake numbers you need to help me understand ! I'm confused only by the absorbance part , what number am I using for the absorbance? Is it Fe3+ added to ScN- absorbance values ? also e = 202 and L = 1.0arrow_forward
- What percent transmittance range and what absorbance range are considered to be the optimum working ranges for spectrochemical measurements?arrow_forwardSketch the main components of an FTIR infrared absorption spectrophotometer.arrow_forwardA student calibrated the mini-spectrophotometer with a blank solution, and then went to check their solution. They got a fingerprint on the cuvette while filling it. Because of this, the expected reading for the absorbance would be too high which would cause the calculated value of K, to be too higharrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning