EGR 2500 – Fall 2023 Laboratory Assignment #1 Technical Content (90%) Report of Group #________ ______/10 A BSTRACT Does the abstract state the principal objectives and scope of the lab assignment, describe the methods employed, summarize the important results, and state the principal conclusions? Does it list the ranges of flowrate and uncertainty values for the experiment, as well as the discharge coefficient values obtained? Does the abstract stand on its own (i.e., not reference figures, tables, equation numbers in the report)? Is the organization logical, and understandable to a reader (from outside this course)? ______/5 D ATA C OLLECTION Has the experiment been properly conducted and has the data been accurately gathered? Was the correct procedure followed and was an adequate number of data points collected? ______/10 T HEORY Are the indirect volume flowrate uncertainty and relative uncertainty equations properly derived? Is the derivation correct? Are the final indirect flow rate uncertainty and relative uncertainty equations shown in symbolic form (not just numbers)? Are the equations for the ideal and corrected venturi and orifice meter flow rates shown properly and expressed in terms of appropriate manometer heights? Does the theory section include a schematic? Does the theory section follow the required guidelines (figure, equation numbers, definition of variables, transition sentences, neat if handwritten, etc.)? ______/15 T ABULAR RESULTS Are at least two tables shown (one for collected data and one for calculated data) and is all of the required data (including volume collection method uncertainty and relative uncertainty, venturi and orifice meter discharge coefficients and ideal/corrected flow rates, as well as % differences) shown? Are there any errors in the data reduction (calculation errors)? Has the data been clearly presented and can one easily relate data from one table to data in the other table(s) (e.g., by a common first column)? Do the tables adhere to the required formatting guidelines (Table number, title, column labels, units, etc.)? Was instrument uncertainty information properly reported? ______/20 G RAPHS Are the required two graphs included (one with trendlines to determine the C d values and the other comparing the flow meter values to the volume collection method values) and plotted correctly?
EGR 2500 – Fall 2023 Laboratory Assignment #1 Are all of the required data/lines included (trendline equations and R 2 values, error bars, 45 degree line, all needed data sets, correct quantities in x and y axes)? Are the graphs clear and complete? Do the graphs include figure numbers, descriptive titles, axes labels, units, and are all symbols or lines identified using a legend? Are discrete markers used for experimental values and are lines used for the trendlines and 45 degree line? Do the graphs adhere to the required formatting guidelines? Are they large enough? ______/20 D ISCUSSION Does the discussion section clearly summarize and discuss the important results, trends and conclusions in light of the data presented in the tables and graphs? Does it address all the questions posed in the lab assignment? Are the main equations shown in the results and discussion section in typed form using an equation editor and do they include equation numbers? Have applications and pros and cons of the various types of flow meters been researched and discussed? Was the validity of the sources of information used discussed? Are general suggestions for experiment improvement or a discussion of problems encountered included? Does it adhere to the guidelines? ______/5 R EFERENCES Are references for applications of the different types of flow meters included and properly cited in the report according to the guidelines stated in the lab report handout? ______/3 S AMPLE C ALCULATIONS Are sample calculations correct and reasonably done? Is a sample calculation shown for each type of calculation done (flow rates, uncertainty, relative uncertainty, percent difference)? Are all units and unit conversions shown in the sample calculations? ______/2 A PPENDIX Are the original raw data sheet and the lab handout included? Presentation (10%) ______/5 Is everything spelled correctly? Are there errors in grammar or punctuation? ______/5 Is the document neat and attractive? Is a consistent format used for text and figures throughout the report? ______/100 TOTAL Grader Comments are in the report.
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help