Quiz 1

.docx

School

Defense Acquisition University *

*We aren’t endorsed by this school

Course

EET390

Subject

Mechanical Engineering

Date

Dec 6, 2023

Type

docx

Pages

2

Uploaded by charleshaskett

Report
1. Arc burns are a result of the extremely high temperature caused by an electric arc in close proximity to the body. True 2. The motor nameplate Code letter specifies the locked rotor current rating of the motor in KVA per HP 3. Manual motor starters allow a motor to be controlled from a remote location. False 4. "Dead" circuits should be checked by metering the voltage locked out and tagged out before starting any repairs 5. Three-wire control circuits use a ___________-contact type of control device. Momentary 6. A relatively small percentage of workplace accidents are associated with arc flash. False 7. Metal hard hats are acceptable when performing electrical work. False 8. As part of the lockout/tagout process, all interlocking or dependent systems must also be deactivated and de-energized. True 9. The pathway taken by electricity through the body has little influence on the severity of an electric shock. False 10. NEMA requires that the motor be able to carry their rated horsepower at nameplate voltage plus or minus 10% 11. Which of the following diagrams shows all physical connections of both internal and external wiring involved in the installation of a piece of electrical equipment? diagram of connections 12. You can reverse the direction of rotation of a 3-phase motor by reversing any two of the three main power leads to the motor. True 13. If a control circuit is supplied from a grounded circuit, it makes no difference what side of the line is grounded. False
14. The two basic parts of a typical motor circuit are the control circuit and power circuit 15. If the current in the neutral wire is ______ the current in the hot conductor, a ground fault condition exists. less than 16. GFCI protection is not required on temporarily wired construction sites. False 17. OSHA sets safety standards for the workplace and conducts inspection tours to ensure compliance. 18. The nameplate of a motor indicates that it thermal protected. This means the motor has a built in thermal device 19. Broken lines on a diagram are usually used to show mechanical connections. True 20. Which of the following safety solution is most suitable for safeguarding the interior of robotic work cell? safety laser scanner
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help