DIDE220_Assignment_03_Palak_dang

.pdf

School

Yorkville University *

*We aren’t endorsed by this school

Course

DIDE220

Subject

Mechanical Engineering

Date

Apr 3, 2024

Type

pdf

Pages

3

Uploaded by thepalakdang

W WW.YORKVILLEU.CA DIDE220 A SSIGNMENT 3 1 Assignment 3 Answer Sheet The following sheet should be utilized to complete the assignment effectively. Fill in the required columns to complete the assignment and create a PDF to hand in. Part 1 Review the Building Utilizing the provided reference floor plans, review the building occupancies under Part 9 of the OBC and classify the following: Question Answer OBC Reference Occupancy Classification(s) GROUP- C & E Table 3.1.2.1. Building Area (in square meters) 183.9 Gross Floor Area (in square meters) 343.2 Part 2 Design of Spaces Using the reference floor plan complete the following: Question SQ.FT. Answer (SQ.M) OBC requirement Comply (Yes/No) GROUND FLOOR UNIT 1 APARTMENT Living Room 127 11.8 13.5 NO Kitchen 120 11.1 3.7 YES Bedroom 132.3 12.3 7 YES 2 nd FLOOR UNIT 2 APARTMENT Living/Dining Room 147 13.7 13.5 YES Kitchen 55 5.1 4.2 YES Bedroom 1 117 10.9 7 YES Bedroom 2 133.9 12.4 9.8 YES UNIT 3 APARTMENT Kitchen/Dining Room 133.8 12.4 4.2 YES Living Room 178 16.5 13.5 YES Bedroom 1 120.8 11.2 9.8 YES Bedroom 2 93.5 8.7 7 YES
W WW.YORKVILLEU.CA DIDE220 A SSIGNMENT 3 2 Part 3 Window Areas Using the reference floor plan, your answers from Part 2, complete the following: Question SQ.FT. SQ.M Window % of Room (window area/room area) OBC % Comply (Yes/No) 2 nd FLOOR UNIT 2 APARTMENT Living/Dining Room 12.6 1.2 9% 10% NO Kitchen 9 0.8 16% 10% YES Bedroom 1 Window 1 9 0.8 7% 5% YES Bedroom 1 Window 2 7 0.7 5% 5% YES Bedroom 2 Window 1 10 0.9 7% 5% YES Bedroom 2 Window 2 18 1.7 13% 5% YES UNIT 3 APARTMENT Kitchen/Dining Room 9 0.8 5% 10% NO Living Room 10.3 1 8% 10% NO Bedroom 1 16.7 1.6 13% 5% YES Bedroom 2 9 0.8 9% 5% YES Part 4 Fire Separations and Exits Using the reference ground floor plan and building information from Part 1, complete the following: Wall Code Fire Resistance Rating OBC Reference W1 45MIN 9.10.9.15 W2 1H 9.10.9.13 & 9.10.9.14 W3 1H 9.10.9.13 & 9.10.9.14 W4 45MIN 9.10.9.15 W5 45MIN 9.10.9.13 & 9.10.9.14 Door Code Fire Resistance Rating OBC Reference D1 20MIN 9.10.13.1 D2 20MIN 9.10.13.1 D3 N/A D4 45MIN SUBSECTION 3.2.2 D5 45 MIN 9.10.13.1
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help