A chromatogram of a two-component mixture on a 25-cm packed LC column is shown in the figure below. The flow rate was 0.40 mL/min. a. Find the times that components A and B spend in the stationary phase. b. Find the retention times for A and B. c. Determine the retention factors for the two components. d. Find the full widths of each peak. e. Find the resolution of the two peaks. f. Find the average number of plates for the column g. Find the average plate height. h. What column length would be needed to achieve a resolution of 1.75? 16 A 14 12 B 0. 0. 10 30 40 50 60 70 Time, min 20 2. 10 Detector response

Principles of Instrumental Analysis
7th Edition
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Chapter27: Gas Chromatography
Section: Chapter Questions
Problem 27.22QAP
icon
Related questions
Question
I just need letter h please
A chromatogram of a two-component mixture on a 25-cm packed LC column is shown in the figure below.
The flow rate was 0.40 mL/min.
a. Find the times that components A and B spend in the stationary phase.
b. Find the retention times for A and B.
c. Determine the retention factors for the two components.
d. Find the full widths of each peak.
e. Find the resolution of the two peaks.
f. Find the average number of plates for the column
g. Find the average plate height.
h. What column length would be needed to achieve a resolution of 1.75?
16
A
14
12
B
0.
10
30
40
50
60
70
Time, min
20
2.
10
Detector response
Transcribed Image Text:A chromatogram of a two-component mixture on a 25-cm packed LC column is shown in the figure below. The flow rate was 0.40 mL/min. a. Find the times that components A and B spend in the stationary phase. b. Find the retention times for A and B. c. Determine the retention factors for the two components. d. Find the full widths of each peak. e. Find the resolution of the two peaks. f. Find the average number of plates for the column g. Find the average plate height. h. What column length would be needed to achieve a resolution of 1.75? 16 A 14 12 B 0. 10 30 40 50 60 70 Time, min 20 2. 10 Detector response
Expert Solution
Step 1

Chemistry homework question answer, step 1, image 1

trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Analytical Separations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
EBK A SMALL SCALE APPROACH TO ORGANIC L
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage