As a newly appointed research officer, Marissa has been assigned a task to separate a mixture containing acetone, acetamide and 1,2-dichloroethane using a high-performance liquid chromatography (HPLC) technique. The instrument was equipped with a 40-cm column packed with cyano propyl bonded to the siloxane backbone material. i) List THREE (3) examples of mobile phase solvent/solvent systems that can be used with the column above. ii) Determine the sequence in which the three analytes eluted from the column and explain the underlying principle applied. iii) Sketch the chromatogram that would be produced if the column was replaced with a column filled with C18 hydrocarbon bound to the siloxane backbone material and acetonitrile was employed as the mobile phase. Label the peaks observed.
As a newly appointed research officer, Marissa has been assigned a task to separate a mixture containing acetone, acetamide and 1,2-dichloroethane using a high-performance liquid chromatography (HPLC) technique. The instrument was equipped with a 40-cm column packed with cyano propyl bonded to the siloxane backbone material. i) List THREE (3) examples of mobile phase solvent/solvent systems that can be used with the column above. ii) Determine the sequence in which the three analytes eluted from the column and explain the underlying principle applied. iii) Sketch the chromatogram that would be produced if the column was replaced with a column filled with C18 hydrocarbon bound to the siloxane backbone material and acetonitrile was employed as the mobile phase. Label the peaks observed.
Macroscale and Microscale Organic Experiments
7th Edition
ISBN:9781305577190
Author:Kenneth L. Williamson, Katherine M. Masters
Publisher:Kenneth L. Williamson, Katherine M. Masters
Chapter7: Extraction
Section: Chapter Questions
Problem 1Q
Related questions
Question
As a newly appointed research officer, Marissa has been assigned a task to separate a mixture containing acetone, acetamide and 1,2-dichloroethane using a high-performance liquid chromatography (HPLC) technique. The instrument was equipped with a 40-cm column packed with cyano propyl bonded to the siloxane backbone material.
i) List THREE (3) examples of mobile phase solvent/solvent systems that can be
used with the column above.
ii) Determine the sequence in which the three analytes eluted from the column and explain the underlying principle applied.
iii) Sketch the chromatogram that would be produced if the column was replaced
with a column filled with C18 hydrocarbon bound to the siloxane backbone material and acetonitrile was employed as the mobile phase. Label the peaks observed.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Recommended textbooks for you
Macroscale and Microscale Organic Experiments
Chemistry
ISBN:
9781305577190
Author:
Kenneth L. Williamson, Katherine M. Masters
Publisher:
Brooks Cole
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Macroscale and Microscale Organic Experiments
Chemistry
ISBN:
9781305577190
Author:
Kenneth L. Williamson, Katherine M. Masters
Publisher:
Brooks Cole
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT