FOX+MCDONALD'S INTRO.TO...-ACCESS+BOX
9th Edition
ISBN: 9781118471340
Author: Pritchard
Publisher: WILEY
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 10, Problem 15P
Kerosene is pumped by a centrifugal pump. When the flow rate is 350 gpm, the pump requires 18 hp input and its efficiency is 82 percent. Calculate the pressure rise produced by the pump. Express this result as (a) feet of water and (b) feet of kerosene.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The pressure at the suction of the pump reads 8
psi vacuum, while at the discharge is 41 psi. The
difference in elevation between the suction and
discharge side is 1.6 ft. The diameter at suction is
7.2 in, while at the discharge is 4.5 in. Calculate
the power delivered by the pump in hp if it
delivers 1800 gpm. Write your answer to 1
decimal place.
Answer:
A submersible pump delivers 350 gpm of water to a height of 5 ft from the ground. The pump were installed 150 ft. Below the ground level and a draw down of 8 ft during the operation. If water level is 25 ft above the pump. Determine the pump power.
A hydraulic pump has a flow rate of 12 gpm and is rated for a maximum pressure of 2000 psi. if the pump is driven at 2100 rpm, what is the maximum Horsepower Output (HPout) of this pump?
Chapter 10 Solutions
FOX+MCDONALD'S INTRO.TO...-ACCESS+BOX
Ch. 10 - The geometry of a centrifugal water pump is r1 =...Ch. 10 - Find the resulting -groups when (a) D, , and Q or...Ch. 10 - Consider the centrifugal pump impeller dimensions...Ch. 10 - Dimensions of a centrifugal pump impeller areCh. 10 - Dimensions of a centrifugal pump impeller areCh. 10 - The blade is one of a series. Calculate the force...Ch. 10 - This blade is one of a series. What force is...Ch. 10 - A centrifugal water pump, with 15-cm-diameter...Ch. 10 - A centrifugal water pump designed to operate at...Ch. 10 - A series of blades, such as in Example 10.13,...
Ch. 10 - In passing through this blade system, the absolute...Ch. 10 - A centrifugal pump runs at 1750 rpm while pumping...Ch. 10 - A centrifugal water pump designed to operate at...Ch. 10 - Kerosene is pumped by a centrifugal pump. When the...Ch. 10 - In the water pump of Problem 10.8, the pump casing...Ch. 10 - Use data from Appendix C to choose points from the...Ch. 10 - Data from tests of a water suction pump operated...Ch. 10 - A centrifugal pump impeller having r1 = 50 mm, r2...Ch. 10 - A centrifugal pump impeller having dimensions and...Ch. 10 - An axial-flow fan operates in sea-level air at...Ch. 10 - Data measured during tests of a centrifugal pump...Ch. 10 - A small centrifugal pump, when tested at N = 2875...Ch. 10 - If the impeller of Problem 10.20 rotates between...Ch. 10 - At the outlet of a pump impeller of diameter 0.6 m...Ch. 10 - Typical performance curves for a centrifugal pump,...Ch. 10 - A pump with D = 500 mm delivers Q = 0.725 m3/s of...Ch. 10 - At its best efficiency point ( = 0.87), a...Ch. 10 - Using the performance curves in Appendix C, select...Ch. 10 - A pumping system must be specified for a lift...Ch. 10 - A centrifugal water pump operates at 1750 rpm; the...Ch. 10 - A set of eight 30-kW motor-pump units is used to...Ch. 10 - A blower has a rotor with 12-in. outside diameter...Ch. 10 - A centrifugal water pump has an impeller with an...Ch. 10 - Appendix C contains area bound curves for pump...Ch. 10 - Use data from Appendix C to verify the similarity...Ch. 10 - A centrifugal water pump has an impeller with...Ch. 10 - Catalog data for a centrifugal water pump at...Ch. 10 - A 1/3 scale model of a centrifugal water pump...Ch. 10 - Sometimes the variation of water viscosity with...Ch. 10 - A large deep fryer at a snack-food plant contains...Ch. 10 - Data from tests of a pump, with a...Ch. 10 - A four-stage boiler feed pump has suction and...Ch. 10 - A centrifugal pump operating at N = 2265 rpm lifts...Ch. 10 - A centrifugal pump is installed in a piping system...Ch. 10 - Part of the water supply for the South Rim of...Ch. 10 - Consider the flow system shown in Problem 8.94....Ch. 10 - Afire nozzle is supplied through 300 ft of...Ch. 10 - Performance data for a centrifugal fan of 3-ft...Ch. 10 - The performance data of Problem 10.57 are for a...Ch. 10 - Experimental test data for an aircraft engine fuel...Ch. 10 - Preliminary calculations for a hydroelectric power...Ch. 10 - Conditions at the inlet to the nozzle of a Pelton...Ch. 10 - A Francis turbine is to operate under a head of 46...Ch. 10 - A Kaplan (propeller with variable-pitch blades)...Ch. 10 - Francis turbine Units 19, 20, and 21, installed at...Ch. 10 - Measured data for performance of the reaction...Ch. 10 - For a flow rate of 12 L/s and turbine speed of 65...Ch. 10 - The velocity of the water jet driving this impulse...Ch. 10 - An impulse turbine is to develop 15 MW from a...Ch. 10 - An impulse turbine under a net head of 33 ft was...Ch. 10 - The absolute velocities and directions of the jets...Ch. 10 - A fanboat in the Florida Everglades is powered by...Ch. 10 - A jet-propelled aircraft traveling at 225 m/s...Ch. 10 - When an air jet of 1-in.-diameter strikes a series...Ch. 10 - The volume flow rate through the propeller of an...Ch. 10 - A typical American multi blade farm windmill has D...Ch. 10 - An airplane flies at 200 km/h through still air of...Ch. 10 - This ducted propeller unit drives a ship through...Ch. 10 - A model of an American multi blade farm windmill...Ch. 10 - A large Darrieus vertical axis wind turbine was...Ch. 10 - Show that this ducted propeller system when moving...Ch. 10 - This ducted propeller unit (now operating as a...Ch. 10 - What is the maximum power that can be expected...Ch. 10 - If an ideal windmill is operating at best...Ch. 10 - A prototype air compressor with a compression...Ch. 10 - Prob. 89PCh. 10 - We have seen many examples in Chapter 7 of...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
Determine the coordinate direction angles of F1. Probs. 2-65/66
INTERNATIONAL EDITION---Engineering Mechanics: Statics, 14th edition (SI unit)
ICA 8-52
The heat transfer coefficient of steel is 25 watts per square meter degree Celsius [W/(m2 °C)]. Conver...
Thinking Like an Engineer: An Active Learning Approach (3rd Edition)
What are some of the Ways in which laser-beam welding is more attractive than electron-beam welding?
Degarmo's Materials And Processes In Manufacturing
If the 30-kg disk is released from rest when = 0 , determine its angular velocity when = 90.
Engineering Mechanics: Dynamics (14th Edition)
ICA 8-52
The heat transfer coefficient of steel is 25 watts per square meter degree Celsius [W/(m2 °C)]. Conver...
Thinking Like an Engineer: An Active Learning Approach (4th Edition)
A pipe flowing light oil has a manometer attached, as shown in Fig, P1.52. What is the absolute pressure in pip...
Fundamentals Of Thermodynamics
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A small centrifugal pump is used to deliver 0.005 m3/s of water to level 2 as shown in Fig. 2. Neglecting the losses, determine the required power input to the pump if its efficiency is equal to 70%.arrow_forwardA water tank with a capacity of 1500 L is desired to be completely filled in about 1.5 hours. The total length of the suction and discharge pipes are 7.1 m and 12 m, respectively. All pipes uses 2 in.-diameter PVC pipes (ε = 0.15 mm). The elevations are shown in the figure below. Calculate the power input (in kW) to the pump if pump efficiency is 86% and motor efficiency is 96%. Take the density of water to be 1000 kg/(m^3) and μ = 1.00E-3 Pa-s.arrow_forwardA fuel pump is delivering 18 gallons per minute of oil with a specific gravity of 0.80. The total head is 75 meters. If the power input to the pump is 1.1 hp, what is the eficiency of the pump?arrow_forward
- A pump operating at 1750 rpm delivering 500 gpm against a total head of 150 ft. Changes in the piping system have increased the total head to 360 ft. At what rpm should the pump be operated to achieve this new head at the same efficiency?arrow_forwardIf the velocity of water is 8m/s and the pressure is 140 kPa on the discharge side of a pump, What will be the head of the pump if the velocity is 4 m/s and the pressure is 90 kPa on the suction side of the pump? How much power is required to drive it if the diameter of suction side is 600 mm? If the pump is rated at 120 hp, what is the efficiency of the pump neglecting energy losses in the system?arrow_forwardA pump must move a discharge of 1.1 cfs against a head of 30 ft. if the pump is driven by a 5 kW motor with an efficiency of 75%, what is the brake horsepower?arrow_forward
- A 20-KW motor with 80% efficiency drives a centrifugal pump delivery 0.08m3/sec against a head of 20m. Determine the pump efficiencyarrow_forward3. A pump discharges into a 3-m-per-side cubical tank. The flow rate is 300 liters/min, fluid has a density 1.2 times that of water. Determine (a) the flow rate in kg/s; (b) the time it takes to fill the tank. and thearrow_forwardChoose the correct answer of the following questions 2. A siphon used to empty a tank consists essentially of a pipe with its summit 0.5 m above the water surface of the tank and its outlet at 2.0 m below the summit. Neglecting friction and other losses. the velocity in the siphon is: a. 4.4 m/sec b. 5.4 m/sec C.3.1 m/sec d. 3.8 m/sec 3. A 20 cm diameter open cylindrical container contains Kerosene (relative density = 0.80) to a height of 20 cm. It is rotated about a vertical axis coinciding with the axis of the cylinder. If the bottom of the cylinder at the axis is just exposed, the speed of rotation is: a. 94.6 rpm br267.5 rpm c. 133.8 rpm d. 535.0 rpmarrow_forward
- A pump has an efficiency of 65%. It is driven by a 0.75 horsepower motor. The pump produces a pressure rise of 0.0174 psi in water. What is the required flow rate in cubic meter per second?arrow_forwardA pump is driven at 1800 RPM and delivers 12 GPM at 2000 psi. If the volumetric efficiency is 90%, Calculate the volumetric displacement of this pump.arrow_forwardC. A pump delivers 25 L/s of water with a head of 35 m and runs at a speed of 2950 rpm for 8 hours per day. The shaft power is 11.5 kW. The electric motor driving the pump has an efficiency of 84% and the cost of electricity is 15 cents per kWh. Evaluate the cost of electricity to run the pump in a day.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Fluid Mechanics - Viscosity and Shear Strain Rate in 9 Minutes!; Author: Less Boring Lectures;https://www.youtube.com/watch?v=_0aaRDAdPTY;License: Standard youtube license