Chapter 10, Problem 46P
A centrifugal pump operating at N = 2265 rpm lifts water between two reservoirs connected by 300 ft of 6-in.-diameter and 100 ft of 3-in.-diameter cast-iron pipe in series. The gravity lift is 25 ft. Estimate the head requirement, power needed, and hourly cost of electrical energy to pump water at 200 gpm to the higher reservoir. Assume that electricity costs 12¢/kW · hr and that the electric motor efficiency is 85 percent.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A 12-in diameter pump rotating at 600 rpm develops a head of 500 ft. Determine the peripheral velocity factor of the pump.
It is proposed to build a three- stage centrifugal pump to deliver 4000 kg/min of water at a speed of 900 rpm under a total manometric head of 70 m. The vanes are to be radial at inlet and are to be curved backwards at exit at an angle of 45°. Assuming manometric efficiency of 84% and overall efficiency of 75% and considering that vane thickness accounts for 8% of circumferential area. The velocity of flow may be assumed constant at 2.5 m/sec. The probable external diameter is ؟
It is proposed to build a three- stage centrifugal pump to deliver 4000 kg/min of water at a speed of 900 rpm under a total manometric head of 70 m. The vanes are to be radial at inlet and are to be curved backwards at exit at an angle of 45°. Assuming manometric efficiency of 84% and overall efficiency of 75% and considering that vane thickness accounts for 8% of circumferential area. The velocity of flow may be assumed constant at 2.5 m/sec. The outlet peripheral speed is ؟
Chapter 10 Solutions
FOX+MCDONALD'S INTRO.TO...-ACCESS+BOX
Ch. 10 - The geometry of a centrifugal water pump is r1 =...Ch. 10 - Find the resulting -groups when (a) D, , and Q or...Ch. 10 - Consider the centrifugal pump impeller dimensions...Ch. 10 - Dimensions of a centrifugal pump impeller areCh. 10 - Dimensions of a centrifugal pump impeller areCh. 10 - The blade is one of a series. Calculate the force...Ch. 10 - This blade is one of a series. What force is...Ch. 10 - A centrifugal water pump, with 15-cm-diameter...Ch. 10 - A centrifugal water pump designed to operate at...Ch. 10 - A series of blades, such as in Example 10.13,...
Ch. 10 - In passing through this blade system, the absolute...Ch. 10 - A centrifugal pump runs at 1750 rpm while pumping...Ch. 10 - A centrifugal water pump designed to operate at...Ch. 10 - Kerosene is pumped by a centrifugal pump. When the...Ch. 10 - In the water pump of Problem 10.8, the pump casing...Ch. 10 - Use data from Appendix C to choose points from the...Ch. 10 - Data from tests of a water suction pump operated...Ch. 10 - A centrifugal pump impeller having r1 = 50 mm, r2...Ch. 10 - A centrifugal pump impeller having dimensions and...Ch. 10 - An axial-flow fan operates in sea-level air at...Ch. 10 - Data measured during tests of a centrifugal pump...Ch. 10 - A small centrifugal pump, when tested at N = 2875...Ch. 10 - If the impeller of Problem 10.20 rotates between...Ch. 10 - At the outlet of a pump impeller of diameter 0.6 m...Ch. 10 - Typical performance curves for a centrifugal pump,...Ch. 10 - A pump with D = 500 mm delivers Q = 0.725 m3/s of...Ch. 10 - At its best efficiency point ( = 0.87), a...Ch. 10 - Using the performance curves in Appendix C, select...Ch. 10 - A pumping system must be specified for a lift...Ch. 10 - A centrifugal water pump operates at 1750 rpm; the...Ch. 10 - A set of eight 30-kW motor-pump units is used to...Ch. 10 - A blower has a rotor with 12-in. outside diameter...Ch. 10 - A centrifugal water pump has an impeller with an...Ch. 10 - Appendix C contains area bound curves for pump...Ch. 10 - Use data from Appendix C to verify the similarity...Ch. 10 - A centrifugal water pump has an impeller with...Ch. 10 - Catalog data for a centrifugal water pump at...Ch. 10 - A 1/3 scale model of a centrifugal water pump...Ch. 10 - Sometimes the variation of water viscosity with...Ch. 10 - A large deep fryer at a snack-food plant contains...Ch. 10 - Data from tests of a pump, with a...Ch. 10 - A four-stage boiler feed pump has suction and...Ch. 10 - A centrifugal pump operating at N = 2265 rpm lifts...Ch. 10 - A centrifugal pump is installed in a piping system...Ch. 10 - Part of the water supply for the South Rim of...Ch. 10 - Consider the flow system shown in Problem 8.94....Ch. 10 - Afire nozzle is supplied through 300 ft of...Ch. 10 - Performance data for a centrifugal fan of 3-ft...Ch. 10 - The performance data of Problem 10.57 are for a...Ch. 10 - Experimental test data for an aircraft engine fuel...Ch. 10 - Preliminary calculations for a hydroelectric power...Ch. 10 - Conditions at the inlet to the nozzle of a Pelton...Ch. 10 - A Francis turbine is to operate under a head of 46...Ch. 10 - A Kaplan (propeller with variable-pitch blades)...Ch. 10 - Francis turbine Units 19, 20, and 21, installed at...Ch. 10 - Measured data for performance of the reaction...Ch. 10 - For a flow rate of 12 L/s and turbine speed of 65...Ch. 10 - The velocity of the water jet driving this impulse...Ch. 10 - An impulse turbine is to develop 15 MW from a...Ch. 10 - An impulse turbine under a net head of 33 ft was...Ch. 10 - The absolute velocities and directions of the jets...Ch. 10 - A fanboat in the Florida Everglades is powered by...Ch. 10 - A jet-propelled aircraft traveling at 225 m/s...Ch. 10 - When an air jet of 1-in.-diameter strikes a series...Ch. 10 - The volume flow rate through the propeller of an...Ch. 10 - A typical American multi blade farm windmill has D...Ch. 10 - An airplane flies at 200 km/h through still air of...Ch. 10 - This ducted propeller unit drives a ship through...Ch. 10 - A model of an American multi blade farm windmill...Ch. 10 - A large Darrieus vertical axis wind turbine was...Ch. 10 - Show that this ducted propeller system when moving...Ch. 10 - This ducted propeller unit (now operating as a...Ch. 10 - What is the maximum power that can be expected...Ch. 10 - If an ideal windmill is operating at best...Ch. 10 - A prototype air compressor with a compression...Ch. 10 - Prob. 89PCh. 10 - We have seen many examples in Chapter 7 of...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
Modified coefficient of performance and power input for clean condition.
Introduction to Heat Transfer
Determine the maximum normal stress developed in the bar when it is subjected to a tension of P = 8kN.
Mechanics of Materials
An insulated cylinder is divided into two pans of 1 m3 each by an initially locked piston, as shown in Fig. P3....
Fundamentals Of Thermodynamics
Wetsuits are prohibited in some triathlons due to the added buoyancy they provide the swimmer, essentially hold...
Applied Fluid Mechanics (7th Edition)
A biological fluid moves at a flow rate of m=0.02kg/s through a coiled, thin-walled, 5-mm-diameter tube submerg...
Fundamentals of Heat and Mass Transfer
The assembly consists of two A992 steel bolts AB and EF and an 6061-T6 aluminum rod CD. When the temperature is...
Mechanics of Materials (10th Edition)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- It is proposed to build a three- stage centrifugal pump to deliver 4000 kg/min of water at a speed of 900 rpm under a total manometric head of 70 m. The vanes are to be radial at inlet and are to be curved backwards at exit at an angle of 45°. Assuming manometric efficiency of 84% and overall efficiency of 75% and considering that vane thickness accounts for 8% of circumferential area. The velocity of flow may be assumed constant at 2.5 m/sec. The width of each impeller is , The probable external diameter is , The outlet peripheral speed is , The h.p. input necessary isarrow_forwardIt is proposed to build a three- stage centrifugal pump to deliver 4000 kg/min of water at a speed of 900 rpm under a total manometric head of 70 m. The vanes are to be radial at inlet and are to be curved backwards at exit at an angle of 45°. Assuming manometric efficiency of 84% and overall efficiency of 75% and considering that vane thickness accounts for 8% of circumferential area. The velocity of flow may be assumed constant at 2.5 m/sec. The width of each impeller is ؟arrow_forwardAssume that friction in the suction line is negligible. Toluene @ 35C is pumped from an open reservoir to a tank kept at a gauge pressure of 150 kPa. The pump itself is 3 m below the reservoir, while the discharge tank is 10m above the reservoir. While in the discharge line the friction head amounts to 7.5 m, determine the net positive suction head available for the pump. If the pump has an efficiency of 65%, determine the total power input. At the given temp, the density and vapor pressure of toluene are 862 kg/m3 and 40 mmHg.arrow_forward
- The manometric head developed by a three-stage centrifugal pump runningat 450 rpm is 60 m. The width and diameter of each impeller at the outlet are60 mm and 750 mm, respectively, with outlet blade angle 45°. Determine itsmanometric efficiency, if discharge through the pump is 0.3 m^3/s.arrow_forwardToluene at 35 degrees Celsius is pumped from an open reservoir to a tank kept at a gauge pressure of 150 kPa. The pump itself is 3m below the reservoir, while the discharge tank is 10m above the reservoir. Assuming friction in the suction line is negligible, while in the discharge line the friction head amounts to 7.5 m, determine the net positive suction head available for the pump. If the pump has an efficiency of 65%, determine the total power input. At the given temperature, the density and vapor pressure of toluene are 862 kg/m3 and 40 mmHgarrow_forwardA 300 mm diameter pump rotating at 600 rpm develops a head of 150 m. Determine the peripheral velocity factor of the pump.arrow_forward
- A plant has installed a single suction centrifugal pump with a discharge of 68 m3/hr under 60 m head and running at 1200 rpm. It is proposed to install another pump with double suction but of the same type to operate at 37.22 m head and deliver 90 m3/hr. Determine the speed of the new pump. and what should be the new impeller diameter if the diameter of the original pump is 140mm?arrow_forwardA turbine develops 144 HP running at 100 rpm under a head of 7.7 meters. After resolving the turbine speed, what horsepower would be developed under a head of 11 meters?arrow_forwardA volute centrifugal pump with an impeller diameter of 0.02 m has the following performance data when pumping water at the best efficiency point: impeller speed N = 58.3 revs/s capacity Q = 0.012 m3/s total head Ah = 70m required net positive suction head NPSH = 18m brake power Pe = 12000w Determine the new performance data (listed above) of a homologous pump with twice the impeller diameter operating at half the impeller speedand same efficiency.arrow_forward
- A Francis radial-flow hydroturbine is being designed with the following dimensions: r2 = 2.00 m, r1 = 1.42 m, b2 = 0.731 m, and b1 = 2.20 m. The runner rotates at n. = 180 rpm. The wicket gates turn the flow by angle ?2 = 30° from radial at the runner inlet, and the flow at the runner outlet is at angle ?1 = 10° from radial. The volume flow rate at design conditions is 340 m3 /s, and the gross head provided by the dam is Hgross = 90.0 m. For the preliminary design, irreversible losses are neglected. Calculate the turbine specific speed of the turbine. Provide answers in both dimensionless form and in customary U.S. units. Is it in the normal range for a Francis turbine? If not, what type of turbine would be more appropriate?arrow_forwardA Francis radial-flow hydroturbine is being designed with the following dimensions: r2 = 2.00 m, r1 = 1.42 m, b2 = 0.731 m, and b1 = 2.20 m. The runner rotates at n. = 180 rpm. The wicket gates turn the flow by angle ?2 = 30° from radial at the runner inlet, and the flow at the runner outlet is at angle ?1 = 10° from radial. The volume flow rate at design conditions is 340 m3 /s, and the gross head provided by the dam is Hgross = 90.0 m. For the preliminary design, irreversible losses are neglected. Calculate the inlet and outlet runner blade angles ?2 and ?1, respectively, and predict the power output (MW) and required net head (m). Is the design feasible?arrow_forwardThe turbine of a micro-hydroelectric power plant delivers 65hp at 75% efficiency. If the effective head is 115ft, how many cubic feet per minute of water must be used.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Fluid Mechanics - Viscosity and Shear Strain Rate in 9 Minutes!; Author: Less Boring Lectures;https://www.youtube.com/watch?v=_0aaRDAdPTY;License: Standard youtube license