Thermodynamics: An Engineering Approach
9th Edition
ISBN: 9781259822674
Author: Yunus A. Cengel Dr., Michael A. Boles
Publisher: McGraw-Hill Education
expand_more
expand_more
format_list_bulleted
Question
Chapter 14.7, Problem 59P
To determine
Sensible, latent, and total infiltration heat load of a building at sea level.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Air enters the heating section of an air-conditioning at 1atm, 10C, and 70 percent relative humidity at a rate of 35m^3/min, and it leaves the humidifying section at 20C with a relative humidity of 90 percent. If the humidifier supplies wet steam at 100C, determine:
The temperature and relative humidity of the air leaving the heating section
The rate of heat transfer in the heating section
For air at 80 8C dry bulb temperature and 20 8C dew-point temperature, determine its humidity, relative humidity, wet bulb temperature, enthalpy, humidvolume and humid heat.
If the relative humidity of air is 77 % at 18.0°C, what is the partial pressure of water vapor in the air in the unit of kPa? The saturation water vapor pressure at 18.0°C is 2.07 kPa
Chapter 14 Solutions
Thermodynamics: An Engineering Approach
Ch. 14.7 - What is the difference between dry air and...Ch. 14.7 - What is vapor pressure?Ch. 14.7 - What is the difference between the specific...Ch. 14.7 - Can the water vapor in air be treated as an ideal...Ch. 14.7 - Explain how vapor pressure of the ambient air is...Ch. 14.7 - Is the relative humidity of saturated air...Ch. 14.7 - Moist air is passed through a cooling section...Ch. 14.7 - How will (a) the specific humidity and (b) the...Ch. 14.7 - Prob. 9PCh. 14.7 - Consider a tank that contains moist air at 3 atm...
Ch. 14.7 - Is it possible to obtain saturated air from...Ch. 14.7 - Why are the chilled water lines always wrapped...Ch. 14.7 - How would you compare the enthalpy of water vapor...Ch. 14.7 - A tank contains 15 kg of dry air and 0.17 kg of...Ch. 14.7 - Prob. 15PCh. 14.7 - An 8-m3 tank contains saturated air at 30C, 105...Ch. 14.7 - Determine the masses of dry air and the water...Ch. 14.7 - A room contains air at 85F and 13.5 psia at a...Ch. 14.7 - Prob. 19PCh. 14.7 - Prob. 20PCh. 14.7 - Prob. 21PCh. 14.7 - In summer, the outer surface of a glass filled...Ch. 14.7 - In some climates, cleaning the ice off the...Ch. 14.7 - Andy and Wendy both wear glasses. On a cold winter...Ch. 14.7 - Prob. 25PCh. 14.7 - Prob. 26PCh. 14.7 - Prob. 27PCh. 14.7 - A thirsty woman opens the refrigerator and picks...Ch. 14.7 - The air in a room has a dry-bulb temperature of...Ch. 14.7 - Prob. 31PCh. 14.7 - Prob. 32PCh. 14.7 - Prob. 33PCh. 14.7 - How do constant-enthalpy and...Ch. 14.7 - At what states on the psychrometric chart are the...Ch. 14.7 - How is the dew-point temperature at a specified...Ch. 14.7 - Can the enthalpy values determined from a...Ch. 14.7 - Atmospheric air at a pressure of 1 atm and...Ch. 14.7 - Prob. 39PCh. 14.7 - Prob. 40PCh. 14.7 - Prob. 41PCh. 14.7 - Atmospheric air at a pressure of 1 atm and...Ch. 14.7 - Reconsider Prob. 1443. Determine the adiabatic...Ch. 14.7 - What does a modern air-conditioning system do...Ch. 14.7 - How does the human body respond to (a) hot...Ch. 14.7 - How does the air motion in the vicinity of the...Ch. 14.7 - Consider a tennis match in cold weather where both...Ch. 14.7 - Prob. 49PCh. 14.7 - Prob. 50PCh. 14.7 - Prob. 51PCh. 14.7 - Prob. 52PCh. 14.7 - What is metabolism? What is the range of metabolic...Ch. 14.7 - Why is the metabolic rate of women, in general,...Ch. 14.7 - What is sensible heat? How is the sensible heat...Ch. 14.7 - Prob. 56PCh. 14.7 - Prob. 57PCh. 14.7 - Prob. 58PCh. 14.7 - Prob. 59PCh. 14.7 - Repeat Prob. 1459 for an infiltration rate of 1.8...Ch. 14.7 - An average (1.82 kg or 4.0 lbm) chicken has a...Ch. 14.7 - An average person produces 0.25 kg of moisture...Ch. 14.7 - How do relative and specific humidities change...Ch. 14.7 - Prob. 64PCh. 14.7 - Humid air at 150 kPa, 40C, and 70 percent relative...Ch. 14.7 - Humid air at 40 psia, 50F, and 90 percent relative...Ch. 14.7 - Prob. 67PCh. 14.7 - Air enters a 30-cm-diameter cooling section at 1...Ch. 14.7 - Prob. 69PCh. 14.7 - Prob. 70PCh. 14.7 - Why is heated air sometimes humidified?Ch. 14.7 - Air at 1 atm, 15C, and 60 percent relative...Ch. 14.7 - Air at 14.7 psia, 35F, and 50 percent relative...Ch. 14.7 - An air-conditioning system operates at a total...Ch. 14.7 - Prob. 75PCh. 14.7 - Why is cooled air sometimes reheated in summer...Ch. 14.7 - Atmospheric air at 1 atm, 30C, and 80 percent...Ch. 14.7 - Ten thousand cubic feet per hour of atmospheric...Ch. 14.7 - Air enters a 40-cm-diameter cooling section at 1...Ch. 14.7 - Repeat Prob. 1479 for a total pressure of 88 kPa...Ch. 14.7 - On a summer day in New Orleans, Louisiana, the...Ch. 14.7 - Prob. 83PCh. 14.7 - Prob. 84PCh. 14.7 - Prob. 85PCh. 14.7 - Saturated humid air at 70 psia and 200F is cooled...Ch. 14.7 - Humid air is to be conditioned in a...Ch. 14.7 - Atmospheric air at 1 atm, 32C, and 95 percent...Ch. 14.7 - Prob. 89PCh. 14.7 - Prob. 90PCh. 14.7 - Does an evaporation process have to involve heat...Ch. 14.7 - Prob. 92PCh. 14.7 - Prob. 93PCh. 14.7 - Air enters an evaporative (or swamp) cooler at...Ch. 14.7 - Prob. 95PCh. 14.7 - Air at 1 atm, 20C, and 70 percent relative...Ch. 14.7 - Two unsaturated airstreams are mixed...Ch. 14.7 - Consider the adiabatic mixing of two airstreams....Ch. 14.7 - Two airstreams are mixed steadily and...Ch. 14.7 - A stream of warm air with a dry-bulb temperature...Ch. 14.7 - Prob. 104PCh. 14.7 - Prob. 105PCh. 14.7 - How does a natural-draft wet cooling tower work?Ch. 14.7 - What is a spray pond? How does its performance...Ch. 14.7 - The cooling water from the condenser of a power...Ch. 14.7 - A wet cooling tower is to cool 60 kg/s of water...Ch. 14.7 - Prob. 110PCh. 14.7 - Prob. 111PCh. 14.7 - Water at 30C is to be cooled to 22C in a cooling...Ch. 14.7 - Prob. 113PCh. 14.7 - Prob. 114RPCh. 14.7 - Determine the mole fraction of dry air at the...Ch. 14.7 - Prob. 116RPCh. 14.7 - Prob. 117RPCh. 14.7 - Prob. 118RPCh. 14.7 - Prob. 119RPCh. 14.7 - Prob. 120RPCh. 14.7 - Prob. 121RPCh. 14.7 - Prob. 122RPCh. 14.7 - Prob. 124RPCh. 14.7 - Prob. 125RPCh. 14.7 - Prob. 126RPCh. 14.7 - Prob. 128RPCh. 14.7 - Prob. 129RPCh. 14.7 - Air enters a cooling section at 97 kPa, 35C, and...Ch. 14.7 - Prob. 131RPCh. 14.7 - Atmospheric air enters an air-conditioning system...Ch. 14.7 - Humid air at 101.3 kPa, 36C dry bulb and 65...Ch. 14.7 - An automobile air conditioner uses...Ch. 14.7 - Prob. 135RPCh. 14.7 - Prob. 137RPCh. 14.7 - Conditioned air at 13C and 90 percent relative...Ch. 14.7 - Prob. 141FEPCh. 14.7 - A 40-m3 room contains air at 30C and a total...Ch. 14.7 - A room is filled with saturated moist air at 25C...Ch. 14.7 - Prob. 144FEPCh. 14.7 - The air in a house is at 25C and 65 percent...Ch. 14.7 - Prob. 146FEPCh. 14.7 - Air at a total pressure of 90 kPa, 15C, and 75...Ch. 14.7 - On the psychrometric chart, a cooling and...Ch. 14.7 - On the psychrometric chart, a heating and...Ch. 14.7 - An airstream at a specified temperature and...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Air enters a window air conditioner at 1 atm, 32oC, and 65 percent relative humidity ata rate of 80 kg/min, and leaves at 20oC with 50 percent relative humidity. Determinethe cooling capacity of the A.C. in tons and the moisture removal from the air in kg/s.arrow_forwardA cooling duct receives air at 1 atm, 32°C, and 70% relative humidity with a velocity of 120m/min. This air passes over cooling coils filled with flowing water. This steadily flowing water experiences a for temperature rise during its time in the cooling duct coils. Meanwhile, the airflow leaves the cooling section saturated at 20°C. Determine (a) the rate of heat transfer, (b) the mass flow rate of the cooling water, (c) the flow rate of any condensate formed, and (d) the exit velocity of the air stream. Assume the cooling water has constant specific heat. Feel free to use the psychrometric chart on the next page for the air properties.arrow_forwardAn air-conditioning system operates at a total pressure of 1 atm and consists of a heating section and anevaporative cooler. Air enters the heating section at 14°C and 60 percent relative humidity at a rate of 30m3/min, and it leaves the evaporative cooler at 25°C and 45 percent relatively humidity. Determine (a) thetemperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in theheating section, and (c) the rate of water added to air in the evaporative cooler.arrow_forward
- Air at 30 ºC with a dew point of 14ºC enters a textile dryer at a rate of 15.3 m3/min and leaves saturated. The dryer operates adiabatically. Use the psychrometric chart to determine the absolute humidity and humid volume of the entering air, and then use the results to determine the flow rate of dry air (kg/min) through the dryer, thefinal temperature of the air, and the rate (kg/min) at which water is evaporated in the dryer.arrow_forwardIn your own words, answer the following questions: 1. What is the dew-point temperature? 2. How does the air motion in the vicinity of the human body affect human comfort? 3. What is the difference between dry air and atmospheric air? 4. Describe the difference between mass fraction and mole fractionarrow_forwardIt is desired to reduce the temperature of the ambient air entering an air handling unit at a volumetric flow rate of 550 m3/min, at a temperature of 35°C and a relative humidity of 0.75 to 20°C and its relative humidity to 0.45. For this purpose, the air is first cooled to a temperature below the dew point by passing through a cooling coil, and after some moisture is taken by condensation, its temperature is increased to 20˚C by passing over a heating coil. In this way, the temperature of the ambient air at the outlet of the air handling unit is brought to 20˚C and its relative humidity to 0.45. It is assumed that the pressure remains constant at P=100 kPa. Relationships will be used in the calculations. a) Calculate the amount of moisture condensed per unit time.b) Find the amount of heat drawn from the air by the cooling coil.c) Calculate the amount of heat given to the air by the heating coil.d) Show the phase changes on the psychrometric diagram.arrow_forward
- Atmospheric air at 760 mm Hg is at 22°C dry bulb temperature and 20°C wet bulb temperature. Using the psychrometric chart, determine: Relative humidity. Humidity ratio. Dew-point temperature. Enthalpy of air per kg dry air. Volume of moist air/kg dry air.arrow_forwardDetermine the dew point temperature, %RH, partial pressure of dry air, specific humidity, enthalpy, and specific volume of moist air with standard atmospheric pressure and tdb = 25°C and twb = 20°Carrow_forward8. Moist air undergoes a heating and humidification process at a pressure of 101.325 kPa from an initial state of 15°C db and 90% relative humidity to a final state at 22°C and 70% relative humidity. If the mass flow rate of the air at the initial state is 24.5 kg da/s, what is the increase in the water content of the air? Express your answer in kg/s. In your written solution, draw the process in the psychrometric chart, show the initial and final state and the values obtained from the chart.arrow_forward
- Humid air at 40 psia, 50oF, and 90 percent relative humidity is heated in a pipe at constant pressure to 120oF. Calculate the relative humidity at the pipe outlet and the amount of heat, in Btu/lbm dry air, required.arrow_forwardair flowing at 2 kg / s has a dry bulb temperature of 50 ° C and a wet bulb temperature of 30 ° C, mixed with air flowing at 3kg / s at 25 ° C and a relative humidity of 70%. Using the psycometry chart determine the ratio, enthalpy and temperature of the dry ballarrow_forwardThe process of oxidizing air in a humidifier, air at a dry bulb temperature of 25 degrees Celsius and RH 10% increases the RH to 45%. Determine the amount of moisture added to the humidifier per kg of dry air. = (kg of water / kg of air)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Heat Transfer – Conduction, Convection and Radiation; Author: NG Science;https://www.youtube.com/watch?v=Me60Ti0E_rY;License: Standard youtube license