Question
Book Icon
Chapter 18, Problem 18.6QAP
Interpretation Introduction

(a)

Interpretation:

The circumstances under which a helium-neon laser would be preferable to an argon-ion laser should be determined.

Concept introduction:

The helium-neon laser is working at a wavelength of 632.8nm. It contains 25% of neon and 75% of helium. The Argon-ion laser is a powerful gas laser. It generates multiples colour beam such as green or blue beam.

Interpretation Introduction

(b)

Interpretation:

The circumstances under which a diode laser would be preferable to an argon-ion laser or helium-neon laser should be determined.

Concept introduction:

The diode laser is a light creating device. It is uses semiconductor technology. It can convert electrical energy directly to the light. The helium-neon laser is working at a wavelength of 632.8nm. It contains 25% of neon and 75% of helium. The Argon-ion laser is a powerful gas laser. It generates multiples colour beam such as green or blue beam.

Interpretation Introduction

(c)

Interpretation:

The reasons of UV emitting sources are avoided should be determined.

Concept introduction:

UV rays are visible radiation as such as visible light, signals. Ultraviolet (UV) rays are electromagnetic radiation which transmitted with different frequencies.

Blurred answer
Students have asked these similar questions
(a) Draw a block diagram of an atomic absorption spectrometer (AAS). Briefly describe the function of each components. (b) What is the process of atomization in atomic absorption spectrometer? Describe the steps of the process in the correct sequence.           (c) State TWO interferences that are encountered in atomic absorption spectrometer. Suggest ONE solution to overcome the problem.             (d.) What is the main difference, in terms of instrumentation, between atomic absorption spectrometer and atomic emission spectroscopy?
(i) Explain how the mass of the particle(s) involved affects the separation between energy levels in quantum mechanics. (ii) Explain why the sensitivity of an NMR experiment is affected by the strength of the applied magnetic field. (iii) Explain why, to a good approximation, rotational and vibrational transitions do not change the energies of electrons.
Explain the origin of (a) absorption, (b) phosphorescence, and (c) Raman spectra. You may draw the Jablonski diagram to enhance your explanation.
Knowledge Booster
Background pattern image
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Text book image
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning
Text book image
Physical Chemistry
Chemistry
ISBN:9781133958437
Author:Ball, David W. (david Warren), BAER, Tomas
Publisher:Wadsworth Cengage Learning,
Text book image
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:9781285640686
Author:Skoog
Publisher:Cengage