Question
Chapter 19.2, Problem 22R
To determine
State which article of Code provides the requirement of a hermetic refrigerant motor compressor in heat pump water heaters.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
When installing ceiling-suspended (paddle) fans, per the requirements found in NEC 314.27(C) and NEC 422.18 and the UL Product Spec database, the outlet box or outlet system consist of the following:
QUESTION 9
When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true?
a
A.This would be approved by code as the gas pipe is only being bonded to the electrical system.
b
B.This installation would be approved by code, as the gas pipe is not a grounding electrode.
c
C.Both A and B
d
D.Neither A nor B
The minimum working space width in front of service equipment installed in a house must be ______ inches wide or the width of the equipment, whichever is greater. The minimum amount of clear space in front of service equipment must be at least ______ feet. This space must be maintained to a height from the floor of ______ feet. Name the NEC® section that covers these requirements
Chapter 19 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 19.1 - Does a jet pump have any electrical moving parts...Ch. 19.1 - Prob. 2RCh. 19.1 - Where is the jet of the pump located?...Ch. 19.1 - Prob. 4RCh. 19.1 - Prob. 5RCh. 19.1 - Prob. 6RCh. 19.1 - Prob. 7RCh. 19.1 - What is compressed in the water storage tank?...Ch. 19.1 - Explain the difference between a 2-wire...Ch. 19.1 - Prob. 10R
Ch. 19.1 - Why is a 240-volt motor preferable to a 120-volt...Ch. 19.1 - How many amperes does a 1-horsepower, 240-volt,...Ch. 19.1 - What size are the conductors used for this branch...Ch. 19.1 - Prob. 14RCh. 19.1 - What provides the running overload protection for...Ch. 19.1 - What is the maximum ampere setting permitted for...Ch. 19.1 - Prob. 17RCh. 19.1 - Because the controller contains the motor starting...Ch. 19.1 - Prob. 19RCh. 19.1 - Proper pressure of the submersible pump system is...Ch. 19.1 - Fill in the data for a 16-ampere electric motor,...Ch. 19.1 - The NEC is very specific in its requirement that...Ch. 19.1 - Does the NEC allow submersible pump cable to be...Ch. 19.1 - Must the disconnect switch for a submersible pump...Ch. 19.1 - A metal well casing (shall) (shall not) be bonded...Ch. 19.2 - Prob. 1RCh. 19.2 - A major hazard involved with water heaters is that...Ch. 19.2 - Prob. 3RCh. 19.2 - The heating elements in electric water heaters are...Ch. 19.2 - An 80-gallon electric water heater is energized...Ch. 19.2 - Prob. 6RCh. 19.2 - For residential water heaters, the Consumer...Ch. 19.2 - An 80-gallon electric water heater has 60F...Ch. 19.2 - Approximately how long would it take to produce...Ch. 19.2 - Two thermostats are generally used in an electric...Ch. 19.2 - a. How many heating elements are provided in the...Ch. 19.2 - When does the lower heating element operate?...Ch. 19.2 - Prob. 14RCh. 19.2 - Prob. 15RCh. 19.2 - Prob. 16RCh. 19.2 - a. If both elements of the water heater in this...Ch. 19.2 - a. How much power in watts would the two elements...Ch. 19.2 - A condominium owner complains of not getting...Ch. 19.2 - For a single, nonmotor-operated electrical...Ch. 19.2 - A 7000-watt resistance-type heating appliance is...Ch. 19.2 - Prob. 22R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwardThe total estimated volt-ampere load of the garage lighting branch circuit B14 draws how many amperes? Show your calculations.______________________________ __________________________________ __________________________________arrow_forwardDuplex receptacles connected to the 20-ampere small-appliance branch circuits in kitchens and dining rooms (Circle the correct answer): a. may be rated 15 amperes.(True)(False) b. must be rated 15 amperes.(True)(False) c. may be rated 20 amperes.(True)(False) d. must be rated 20 amperes.(True)(False)arrow_forward
- Determine the proper size of copper wire conductor necessary to apply a 750 W electric motor that is located 100 feet from the panel board. The voltage at the panelboard is 120 volts. The permissible line drop is 1.2 volts. (for your final answer: no decimal places and unit to have one common answer)arrow_forwardCalculate the watts loss and voltage drop in each conductor in the following circuit. Show calculations. Obtain resistance data from Table 8, Chapter 9, of the NEC.arrow_forwardNEC 210.12(A) requires AFCI protection for the branch-circuit wiring that supplies all electrical outlets in specific rooms in dwellings. The branch circuits serving which areas, locations, or rooms in dwellings are not required to have AFCI protection?arrow_forward
- electrical wiring 20th edition residential book chapter 12 review question #27 The following is a layout for the lighting circuit for the Kitchen. Complete the wiring diagram using colored pens or pencils to show the conductors’ insulation color.arrow_forwardCan you finish the Background including a synopsis of the relevant information of this this example "electrical maintenance and repair" And please cite an article or paraphrase of author. Thank you! The electrical wiring and electrical devices in the houses that are installed may have failure so the inspection is designed to definitely perform the clear capabilities. These electrical devices are...arrow_forwardelectrical wiring 20th edition residential chapter 12 review question #27 The following is a layout for the lighting circuit for the Kitchen. Complete the wiring diagram using colored pens or pencils to show the conductors’ insulation color.arrow_forward
- 8. What is the maximum load to be connected to a single receptacle rated at 20A?arrow_forwardThe minimum number of outdoor receptacles for a residence is __________, NEC __________. State the location. __________arrow_forwardReceptacle outlets furnished as part of a permanently installed electric baseboard heater, when not connected to the heaters branch circuit, (may) (may not) be counted as the required receptacle outlet for the space occupied by the baseboard heater. Electric baseboard heaters (shall) (shall not) be installed beneath wall receptacle outlets unless the instructions furnished with the heaters indicate that it is acceptable to install the heater below a receptacle outlet. (Circle the correct answers.)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS