Textbook Question
Chapter 19.2, Problem 9R
An 80-gallon electric water heater has 60°F (15.56°C) incoming water. How many minutes can a 3-gallon/minute showerhead be used to draw 105°F (40.56°C) water if the water heater thermostat is set at 120°F (48.89°C)?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
What is the maximum number of 15 ampere lighting circuits required if the dwelling has an occupied area of 4000-sq.ft.
What is the minimum number of 15-ampere lighting branch circuits required if the dwelling has an occupied area of 400 ft2(368m2)
A one-family dwelling has a 175-ampere, 240-volt service that is fed with 75⁰ C (167 degrees) conductors. What is the minimum size copper grounding electrode conductor required ?
Chapter 19 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 19.1 - Does a jet pump have any electrical moving parts...Ch. 19.1 - Prob. 2RCh. 19.1 - Where is the jet of the pump located?...Ch. 19.1 - Prob. 4RCh. 19.1 - Prob. 5RCh. 19.1 - Prob. 6RCh. 19.1 - Prob. 7RCh. 19.1 - What is compressed in the water storage tank?...Ch. 19.1 - Explain the difference between a 2-wire...Ch. 19.1 - Prob. 10R
Ch. 19.1 - Why is a 240-volt motor preferable to a 120-volt...Ch. 19.1 - How many amperes does a 1-horsepower, 240-volt,...Ch. 19.1 - What size are the conductors used for this branch...Ch. 19.1 - Prob. 14RCh. 19.1 - What provides the running overload protection for...Ch. 19.1 - What is the maximum ampere setting permitted for...Ch. 19.1 - Prob. 17RCh. 19.1 - Because the controller contains the motor starting...Ch. 19.1 - Prob. 19RCh. 19.1 - Proper pressure of the submersible pump system is...Ch. 19.1 - Fill in the data for a 16-ampere electric motor,...Ch. 19.1 - The NEC is very specific in its requirement that...Ch. 19.1 - Does the NEC allow submersible pump cable to be...Ch. 19.1 - Must the disconnect switch for a submersible pump...Ch. 19.1 - A metal well casing (shall) (shall not) be bonded...Ch. 19.2 - Prob. 1RCh. 19.2 - A major hazard involved with water heaters is that...Ch. 19.2 - Prob. 3RCh. 19.2 - The heating elements in electric water heaters are...Ch. 19.2 - An 80-gallon electric water heater is energized...Ch. 19.2 - Prob. 6RCh. 19.2 - For residential water heaters, the Consumer...Ch. 19.2 - An 80-gallon electric water heater has 60F...Ch. 19.2 - Approximately how long would it take to produce...Ch. 19.2 - Two thermostats are generally used in an electric...Ch. 19.2 - a. How many heating elements are provided in the...Ch. 19.2 - When does the lower heating element operate?...Ch. 19.2 - Prob. 14RCh. 19.2 - Prob. 15RCh. 19.2 - Prob. 16RCh. 19.2 - a. If both elements of the water heater in this...Ch. 19.2 - a. How much power in watts would the two elements...Ch. 19.2 - A condominium owner complains of not getting...Ch. 19.2 - For a single, nonmotor-operated electrical...Ch. 19.2 - A 7000-watt resistance-type heating appliance is...Ch. 19.2 - Prob. 22R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Can two 25,000-Btu room air conditioners be wired into the same electricalcircuit protected by a 25-ampere fuse? Each air conditioner is rated at 3,050watts for a 230-volt circuit. (This rating is while the air conditioner is runningsteadily.)arrow_forwardA one-family dwelling has six 3-kW electric wall heaters (with individual thermostats) and five room air conditioners. Two air conditioners are rated 10.5 amperes at 230 volts, and the others are rated 7.2 amperes at 115 volts. A service calculation is being performed, using the optional method . How many volt-amperes should be included (after demand factors) for the heating and air conditioning? (Assume heater kW ratings equivalent to kVA)arrow_forwardThe LRT trolley system 10 miles ling is fed by two substations that generate 600 volts and 500 volts, respectively. The resistance of the trolley wire and the rail return is 0.3 ohm per mile. If the car is located 4 miles from the 600-volt station draws 200 A from the line. How much is the current supplied by each station?arrow_forward
- what is the minimum kW service demand load for twenty 6.5-kW electric ranges in a multifamily dwelling?arrow_forwardCalculate the voltage drop of a 120/240 volts, three wire underground residential service installed with 2 AWG aluminum URD cable if the load is 80 amps and the one way length of the underground service conductor is 100 feet.arrow_forwardwhen calculating a dwelling lighting load on the "volt-ampere per ft2" basis, the receptacle load used for floor lamps, table lamps, and so fourtharrow_forward
- Using NEC: What gauge of conductors is required to feed a 240 Volt single-phase air conditioning unit, whose compressor consumes 6000 VA and the condenser motor is 2 amps? Use copper THHN wire connected to 60°C terminals. What is the minimum and maximum allowable ampacity of the air short-circuit protection of the previous example?arrow_forwardCalculate the voltage drop of a 120/240-volt, three-wire underground residential service installed with 2 AWG aluminum URD cable if the load is 80 amps and the one-way length of the underground service conductors is100 feet.arrow_forwardYou have determined that a 4700-ohm, 1⁄2-watt resistor on an electronic cir- cuit board is defective. Assuming room permits, can the resistor be replaced with a 4700-ohm, 1-watt resistor without damage to the rest of the board, or will the higher wattage resistor generate excessive heat that could damage other components?arrow_forward
- You have determined that a 4700-ohm, 1/2-watt resistor on an electronic circuit board is defective. Assuming room permits, can the resistor be replaced with a 4700-ohm, 1-watt resistor without damage to the rest of the board, or will the higher wattage resistor generate excessive heat that could damage other components?arrow_forwardWhat is the minimum number of 15-ampere lighting branch circuits required if the dwelling has an occupied area of 4000 ft2 (368 m2)? Show all calculations.arrow_forwardGiven: a 240-volt, single phase, 17 kW rated electric range is to be installed in a kitchen of a one family dwelling unit. determine the minimum size copper type NM cable the NEC requires to supply this electric range.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License