Chapter 19.2, Problem 5R
An 80-gallon electric water heater is energized for the first time. Approximately how many hours would it take to raise the water temperature 80°F (26.67°C) (from 40°F to 120°F [4.44°C to 48.89°C])? The water heater has a 3000-watt heating element.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A one-family dwelling has a 175-ampere, 240-volt service that is fed with 75⁰ C (167 degrees) conductors. What is the minimum size copper grounding electrode conductor required ?
Can two 25,000-Btu room air conditioners be wired into the same electricalcircuit protected by a 25-ampere fuse? Each air conditioner is rated at 3,050watts for a 230-volt circuit. (This rating is while the air conditioner is runningsteadily.)
The LRT trolley system 10 miles ling is fed by two substations that generate 600 volts and 500 volts, respectively. The resistance of the trolley wire and the rail return is 0.3 ohm per mile. If the car is located 4 miles from the 600-volt station draws 200 A from the line. How much is the current supplied by each station?
Chapter 19 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 19.1 - Does a jet pump have any electrical moving parts...Ch. 19.1 - Prob. 2RCh. 19.1 - Where is the jet of the pump located?...Ch. 19.1 - Prob. 4RCh. 19.1 - Prob. 5RCh. 19.1 - Prob. 6RCh. 19.1 - Prob. 7RCh. 19.1 - What is compressed in the water storage tank?...Ch. 19.1 - Explain the difference between a 2-wire...Ch. 19.1 - Prob. 10R
Ch. 19.1 - Why is a 240-volt motor preferable to a 120-volt...Ch. 19.1 - How many amperes does a 1-horsepower, 240-volt,...Ch. 19.1 - What size are the conductors used for this branch...Ch. 19.1 - Prob. 14RCh. 19.1 - What provides the running overload protection for...Ch. 19.1 - What is the maximum ampere setting permitted for...Ch. 19.1 - Prob. 17RCh. 19.1 - Because the controller contains the motor starting...Ch. 19.1 - Prob. 19RCh. 19.1 - Proper pressure of the submersible pump system is...Ch. 19.1 - Fill in the data for a 16-ampere electric motor,...Ch. 19.1 - The NEC is very specific in its requirement that...Ch. 19.1 - Does the NEC allow submersible pump cable to be...Ch. 19.1 - Must the disconnect switch for a submersible pump...Ch. 19.1 - A metal well casing (shall) (shall not) be bonded...Ch. 19.2 - Prob. 1RCh. 19.2 - A major hazard involved with water heaters is that...Ch. 19.2 - Prob. 3RCh. 19.2 - The heating elements in electric water heaters are...Ch. 19.2 - An 80-gallon electric water heater is energized...Ch. 19.2 - Prob. 6RCh. 19.2 - For residential water heaters, the Consumer...Ch. 19.2 - An 80-gallon electric water heater has 60F...Ch. 19.2 - Approximately how long would it take to produce...Ch. 19.2 - Two thermostats are generally used in an electric...Ch. 19.2 - a. How many heating elements are provided in the...Ch. 19.2 - When does the lower heating element operate?...Ch. 19.2 - Prob. 14RCh. 19.2 - Prob. 15RCh. 19.2 - Prob. 16RCh. 19.2 - a. If both elements of the water heater in this...Ch. 19.2 - a. How much power in watts would the two elements...Ch. 19.2 - A condominium owner complains of not getting...Ch. 19.2 - For a single, nonmotor-operated electrical...Ch. 19.2 - A 7000-watt resistance-type heating appliance is...Ch. 19.2 - Prob. 22R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- What is the calculated load when fixed electric heating is used in a residence? (220.51)arrow_forwardWhat is the minimum number of 15-ampere lighting branch circuits required if the dwelling has an occupied area of 4000 ft2 (368 m2)? Show all calculations.arrow_forwardA one-family dwelling has six 3-kW electric wall heaters (with individual thermostats) and five room air conditioners. Two air conditioners are rated 10.5 amperes at 230 volts, and the others are rated 7.2 amperes at 115 volts. A service calculation is being performed, using the optional method . How many volt-amperes should be included (after demand factors) for the heating and air conditioning? (Assume heater kW ratings equivalent to kVA)arrow_forward
- What is the minimum number of 15-ampere lighting branch circuits required if the dwelling has an occupied area of 400 ft2(368m2)arrow_forwardWhat is the maximum number of 15 ampere lighting circuits required if the dwelling has an occupied area of 4000-sq.ft.arrow_forwardCalculate the voltage drop of a 120/240-volt, three-wire underground residential service installed with 2 AWG aluminum URD cable if the load is 80 amps and the one-way length of the underground service conductors is100 feet.arrow_forward
- Calculate the voltage drop of a 120/240 volts, three wire underground residential service installed with 2 AWG aluminum URD cable if the load is 80 amps and the one way length of the underground service conductor is 100 feet.arrow_forwardA sound level meter is placed in front of a loudspeaker of a 60W audio system reads 70dB. All else being equal, when placed in front of a 120W system, the meter will read ________?arrow_forwardsmall appliance receptacles included in the 3 volt-ampere per square foot load calculationarrow_forward
- What is the demand load for the service for two 3.5-kW wall-mounted ovens and one 5-kW counter-mounted cooking unit ? All of the appliances are supplied from a single branch circuit and are located in the same room of a one-family dwellingarrow_forwardMay the 20-ampere small-appliance branch circuits in the kitchen of a residence also supply the lighting above the kitchen sink and under-cabinet lighting? Check the correct answer. Yes______ No ______arrow_forwardThe branch circuit supplying a fixed electric space heater must be sized to at least ___________ percent of the heaters rating according to NEC ________________.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License