Question
Chapter 20, Problem 20.16QAP
Interpretation Introduction
Interpretation:
The major differences between a tandem in space and tandem in time mass spectrometer with their advantages and disadvantages has to be found.
Concept introduction:
The tandem mass spectrometry is approach used in the instrumental chemistry. In this method the two or more than two mass spectators are joined by using a reaction.
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Want to see the full answer?
Check out a sample textbook solution![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
What are the differences between a mass spectrometer and a IR spectrometer?
Arrange the following steps according to the order of process in Mass spectrometry
Ion Separation
Ionization
Output/Data Result
Detection
Briefly compare the advantages and disadvantages of Nujol mulls and KBr pellets for the analysis of solid samples by IR spectrometry.
Knowledge Booster
Similar questions
- The validation process comprises four main steps that are : hardware validation, software validation, method validation and system suitability. To evaluate a spectrophotometer’s accuracy by measuring absorbance, a solution of 60.06 mg/L K2Cr2O7 in 0.0050M H2SO4 was carefully prepared together with a 0.0050 M H2SO4 as a reagent blank. If the spectrometer’s signal is properly calibrated, it has been reported that this solution should provide an absorbance of 0.640 +- 0.010 at wavelength 350 nm. Which one of the validations mentioned above had been involved in this process? Explain your choicearrow_forwardChemistry Instrumental Analysis Class The experiment is OES: Cleaning Validation of removal of pharmaceutical drugs and calibration standards by fluoresence spectroscopy - Why the instrument use two detectors and monochromators? What type of monochromators are used in our instrument? - Do you think that a similar experiment can be prepared for the analysis of naproxen and benzoic acid? Explain.arrow_forwardIf a TOF mass spectrometer needs to scan an m/z of 600, what is the speed of this ion if it is accelerated through 4000 volts? How long will this ion (at the speed calculated) take to drift 2.00 m through the spectrometer? How many mass spectra can be taken each second if a new cycle begins each time this ion reaches the detector?arrow_forward
- The following calibration data were obtained by an atomic absorption spectrophotometric (AAS) method for the determination of mercury in an herbal product. (show complete solution) 1. What is the detection limit for the method? 2. What is the limit of quantitation for the method?arrow_forwardIn a mass spectrometer, two beams of singly ionized isotopes of uranium 23592U and 23892U are injected with velocity 1.4*105m/s into a magnetic field of strength 0.7 T normally. Compute the distance d between the two trace lines of the isotopes after they complete one semi-circle. (Given: masses of the isotopes are m235 = 3.9*10-25 kg and m238 = 3.95*10-25) a) 1.26 cm b) 0.63 cm c) 0.32 cm d) none of these.arrow_forwardName two advantages of performing a mass spectrometry imaging experiment at high mass resolution (R.P. > 120000)arrow_forward
- Explain the principles of UV-Vis Spectrometerarrow_forwardExplain why the count rate from the detector straight on from the source is much greater than the detector situated in a 45 degree deflection position.What can be deduced from this observation about the structure of the atom and the properties of the nucleus of goldarrow_forwardChemistry Common Isotopes and Mass spectrum of element Mo are given below Most common isotopes: Mo-98; Mo-96 Mo-95; Mo-92; Mo-97 ; Mo-100; Mo-94 Calculate the average atomic mass of Mo How the MS determined the relative intensity (Scale of 100) and Isotope abundance (%)? Why absolute intensity was not used? Can detector sensitivity, ICPMS temperature influence the relative intensity? Explainarrow_forward
- Give at least two reasons for using very dilute solutions when doing fluorescence spectrometryarrow_forwardThe levels of Vitamin B1 in a sample of milk was determined using the Standard Addition method and technique of fluorescence spectroscopy. 18.0 ml of the milk sample was diluted to 20.0 ml using distilled water and then the fluorescence was measured. The resulting signal was 210 units. A spike was made by taking 18.0 ml of the same milk sample, adding 1.0 ml of a 6.0 ppm Vitamin B1 standard solution, and then diluting to 20.0 ml using distilled water. The signal of the spiked milk was 540 units. Calculate the concentration of Vitamin B1 in the original milk sample (in ppm). Report to 3 decimal places.arrow_forwardQ6. (a) Describe the differences between a linear TOF mass spectrometer and an orthogonal TOF instrument? What are the advantages and limitations of these two geometries? * (b) What function does the ICP torch have in ICPMS? (c) Why has ICPMS become an important and widely used analytical method?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781305577213/9781305577213_smallCoverImage.gif)
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning