Question
Chapter 20, Problem 20.3QAP
Interpretation Introduction
Interpretation:
The difference between the fields desorption sources and gaseous field ionization sources is to be stated.
Concept introduction:
Ion source is a device that is used to create ions of atoms and the molecules. These ion sources are of two different types. These are gaseous sources and the desorption sources. These sources are used to produce ions for spectrometers, particle accelerators and ion engines.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
How is the operation of an ion selective probe used to measure pH. How does it specifically relate to the probe interface?
What is the difference between effect of pH and Point of zero charge with regards to Adsorption
What is the correlation of the density of the saltwater mixture and the brightness of the bulb?
Knowledge Booster
Similar questions
- Explain the purpose of the collision cell in interface between inductively coupled plasma and mass spectrometerarrow_forward(c) Batch adsorption of 900 mg/L phenol was studied at 298 K using 50 mL aliquot at an optimized dose of 1.5 g of activated carbon. What is the adsorption capacity in mg/g at an equilibrium concentration of 650 mg/L?arrow_forwardplease provide full solution (a) If k = 0.08 and n = 1.1, predict the value of concentrations from t = 0 h to t = 5 h to the most accurate value. (b) Calculate the sum of the square of the residual (SSR). where SSR = Σ(Predicted data - Measured data)2arrow_forward
- The following data are for the chemisorption of hydrogen on copper powder at 25°C. Confirm that they fit the Langmuir isotherm at low coverages. Then find the value of K for the adsorption equilibrium and the adsorption volume corresponding to complete coverage. \ table V 3 [la, 25, 129,253, 540],[m², 0.042, 0.163,0.221,0.32|]] сarrow_forwardDescribe the components of a filter fluorometer and a spectrofluorometer. Why are fluorometers often more useful than spectrofluorometers for quantitative analysis?arrow_forwardWhy are collision cells a necessary addition to mass spectrometers that employ electrospray ionisation for small molecule structure characterisation?arrow_forward
- Question 9 onlyarrow_forwardRank the following molecules by relative order of elution on silica, from the fastest eluting compound (1) to the slowest (4). Classez les molécules suivantes en ordre relatif d'élution sur la silice, du composé le plus rapide (1) au plus lent (4). HO > د د A به هم مسجد ہو .OH Molecule C Molecule D Molecule A Molecule Barrow_forward(2) The solubility of methane in water at 20 °C and 1.00 x 105 Pa pressure is 0.025 g dm-³. What is its solubility in water at 1.25 x 105 Pa and 20 °C?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you