Chapter 24, Problem 19P
A balanced V load having a 30
a. the phase voltage of the generator.
b. the phase voltage of the load.
c. the phase current of the load.
d. the line current.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Consider the three phase generator below: a) If the stator rotates at 2400 rpm, what is the frequency of the voltage generated? b) If the generator is connected to a balanced, wye-connected, resistive load as shown below and a phase current of 100 A is required, what is the phase voltage that the generator must supply? What is the minimum power rating (in MVA) the three phase generator can have?
1a)Analyze the circuit in Figure 1, consider R = 10
kQ and C = 10 nF. Obtain the mathematical
equation for the equivalent impedance seen by
the generator as a function of frequency. By
voltage division obtain the mathematical
relationship for the voltage across the capacitor
and resistor as a function of VF and frequency.
Perform all the circuit analysis (voltages,
impedances, currents, waveforms).
1b) For the conditions in the previous item,
deduce the value of the frequency that satisfies
|XC| = R.
Vf
f=4 kHz
R=1 kΩ
C=10 nF
Figure 1. Measurement circuit #1.
Y
X
ORC
A wye-connected, 3-phase generator is rated 90 MW, 13.8kV and 0.9 pf. The dc resistance of the armature
is obtained by connected two of its terminals to a 6 Vdc source. The current drawn by the armature is 87.6
A. What is the percent effective resistance of the armature of the generator?
b. 2.2
d. 4.5
a. 2.7
c. 3.1
Chapter 24 Solutions
EBK INTRODUCTORY CIRCUIT ANALYSIS
Ch. 24 - A balanced V load having a 10 resistance in each...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - The phase sequence for the Y-Y system in Fig....Ch. 24 - Repeat Problem 4 if each phase impedance are...Ch. 24 - Repeat Problem 4 if each phase impedance is...Ch. 24 - For the system in Fig. 24.43, find the magnitude...Ch. 24 - Computer the magnitude of the voltage EAB for the...Ch. 24 - For the Y-Y system in Fig. 24.45: a. Find the...Ch. 24 - For the Y-Y system of Fig. 24.46 the impedance of...
Ch. 24 - A balanced load having a 20 resistance in each...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - The phase sequence for the Y- system in Fig....Ch. 24 - Repeat Problem 14 if each phase impedance is...Ch. 24 - Repeat Problem 14 if each phase impedance are...Ch. 24 - Prob. 17PCh. 24 - For the connected load in Fig. 24.49: a. Find the...Ch. 24 - A balanced V load having a 30 resistance in each...Ch. 24 - Repeat Problem 19 if each phase impedance is...Ch. 24 - Prob. 21PCh. 24 - Prob. 22PCh. 24 - Prob. 23PCh. 24 - Repeat Problem 22 if each phase impedance is...Ch. 24 - Prob. 25PCh. 24 - Prob. 26PCh. 24 - Prob. 27PCh. 24 - The phase sequence for the - system in Fig....Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Prob. 31PCh. 24 - Prob. 32PCh. 24 - Prob. 33PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 35PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 38PCh. 24 - Prob. 39PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - A balanced, three-phase, -connected load has a...Ch. 24 - A balanced, three-phase, Y-connected load has a...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - The Y-Y system in Fig. 24.53 has a balanced load...Ch. 24 - Prob. 45PCh. 24 - Prob. 46PCh. 24 - Repeat Problem 46 for the network in Fig. 24.47.Ch. 24 - For the three-wire system in Fig. 24.55, properly...Ch. 24 - Sketch three different ways that two wattmeters...Ch. 24 - For the Y- system in Fig. 24.56: Determine the...Ch. 24 - For the system in Fig. 24.57: Calculate the...Ch. 24 - For the three-phase, three-wire system in Fig....
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- what is the kilowatt rating of a three-phase 975-KVA generator at. a. unity power factor ? b. 80 percent power factor ? c. 50 percent power factor ?arrow_forwardDesign a three-phase system such that the phase current in the generator, lines and charging phase is the same. The phase voltage in the generator must be 1000 [V] with ACB sequence. The connected load must be such that the phase current in each load is 10 [A] and its power factor is 0.97 “lagging”.arrow_forward4- a. b. c.arrow_forward
- A three-phase generator supplied 3.0 kVA at a power factor of 0.8 lagging. If 2200 W are delivered to theload and line losses are 60 W per phase, what are the losses in the generator? Also describe characteristics of the generator.arrow_forwardA generator is rated 100 MW. 13.8 kV and 90% power factor. The effective resistance is 1.5 times the ohmic resistance. The ohmic resistance is obtained by connecting two terminals to a DC source. The current and the voltage are 87.6 Aand 6 V. What is the effective resistance per phase?arrow_forwardQuestion 3. The two parallel loads in the figure shown below are as follows. Load 1 absorbs 24 kW and 12 kVAr and Load 2 consists of a 60 ohms resistor in parallel with a capacitive reactance of 480 ohms. 1. Determine the rms magnitude of the generator voltage Vg if the load voltage Vo is 2,400 volts rms. 2. With Vo as the reference, draw a phasor diagram of the system voltages. 8 + j10 Ω + V₁, L₁ L2arrow_forward
- Three 230 V generators form a delta connected source that is connected to a balanced load of ZL = 10 + j8 Q per phase as shown in Figure below. (a) Determine the value of IAC (b) What is the value of IbB? a A 230/120° 230/0° b B C 230-120°arrow_forwardCan you solve the question step by step clearly ?arrow_forwardCan you explain the given questions in an original way? Single Phase and Three Phase Principles • Single Phase Generators • Two Phase Generatorsarrow_forward
- SHOW COMPLETE SOLUTION A. What is the overall power factor of the two loads as seen by the source? Use two decimal places. B. Determine the magnitude of the current passing through Load 1. Use amperes and two decimal places. C. Is the overall power factor leading or lagging?arrow_forwardH.W 11: Two d.c. generators A and B are connected to a common load. A had a constant e.m.f. of 400 V and internal resistance of 0.25Q while B has a constant e.m.f. of 410 V and an internal resistance of 0.4 Q. Calculate the current and power output from each generator if the load voltage is 390 V. What would be the current and power from each and the terminal voltage if the load was open-circuited ?arrow_forwardThe AC motor M of figure shown in the next slide has 2300 Volts, balanced three phase voltage impressed at its terminals and takes 120 kVA at 0.6 leading power factor. Calculate the line current, total power, and total power factor using V motor as the reference vector. 0.5 +j2 0.5+j2 A - jio007 L-j250 -jioco -jioo M * jioco -j250 0.5+j2 З РHASE B. SOURCE 0.s+j2 AC мотOR -j2so 0.5 +j2 0.5 +j2arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License