A balanced V load having a 30
a. the phase voltage of the generator.
b. the phase voltage of the load.
c. the phase current of the load.
d. the line current.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The load connected to a 3-phase supply comprises three similar coils connected in star. The line currents are 22 A and the kVA rating and power input are 25 kVA and 12 kW respectively. (a) Find the line and phase voltage. (b) If the coils are now connected in delta to the same three phase supply, calculate the line current and phase current
A delta connected balanced 3-phase supply has a line to line voltage of 181 V and supply a line current of 7.6 A to a three phase load. What is the total reactive power supplied by the source if the load power factor is 0.8 lagging (up to two decimal places).
1. Solve the following problem:
A THREE-PHASE CIRCUIT WHERE THE BALANCED DELTA LOAD OF 36 + J54 OHMS IS SUPPLIED BY 8,602 OHMS IMPEDANCE CONDUCTORS WITH A PHASE ANGLE OF 54,462 DEGREES. IF THE GENERATOR VOLTAGE IN PHASE B IS 100 VOLTS ANGLE - 120 DEGREES.
CALCULATE:
A) THE VOLTAGE BC IN LOAD.
B) THE POWERS IN THE CONDUCTORS.
C) THE POWER TRIANGLE IN THE LOAD.
Chapter 24 Solutions
EBK INTRODUCTORY CIRCUIT ANALYSIS
Ch. 24 - A balanced V load having a 10 resistance in each...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - The phase sequence for the Y-Y system in Fig....Ch. 24 - Repeat Problem 4 if each phase impedance are...Ch. 24 - Repeat Problem 4 if each phase impedance is...Ch. 24 - For the system in Fig. 24.43, find the magnitude...Ch. 24 - Computer the magnitude of the voltage EAB for the...Ch. 24 - For the Y-Y system in Fig. 24.45: a. Find the...Ch. 24 - For the Y-Y system of Fig. 24.46 the impedance of...
Ch. 24 - A balanced load having a 20 resistance in each...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - The phase sequence for the Y- system in Fig....Ch. 24 - Repeat Problem 14 if each phase impedance is...Ch. 24 - Repeat Problem 14 if each phase impedance are...Ch. 24 - Prob. 17PCh. 24 - For the connected load in Fig. 24.49: a. Find the...Ch. 24 - A balanced V load having a 30 resistance in each...Ch. 24 - Repeat Problem 19 if each phase impedance is...Ch. 24 - Prob. 21PCh. 24 - Prob. 22PCh. 24 - Prob. 23PCh. 24 - Repeat Problem 22 if each phase impedance is...Ch. 24 - Prob. 25PCh. 24 - Prob. 26PCh. 24 - Prob. 27PCh. 24 - The phase sequence for the - system in Fig....Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Prob. 31PCh. 24 - Prob. 32PCh. 24 - Prob. 33PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 35PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 38PCh. 24 - Prob. 39PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - A balanced, three-phase, -connected load has a...Ch. 24 - A balanced, three-phase, Y-connected load has a...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - The Y-Y system in Fig. 24.53 has a balanced load...Ch. 24 - Prob. 45PCh. 24 - Prob. 46PCh. 24 - Repeat Problem 46 for the network in Fig. 24.47.Ch. 24 - For the three-wire system in Fig. 24.55, properly...Ch. 24 - Sketch three different ways that two wattmeters...Ch. 24 - For the Y- system in Fig. 24.56: Determine the...Ch. 24 - For the system in Fig. 24.57: Calculate the...Ch. 24 - For the three-phase, three-wire system in Fig....
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A balanced 3 phase star connected load draws power from a 420 V supply. Two wattmeter's indicate 9200 W and 3800 W respectively, when connected to measure the input power of the load, the reverse switch being operated on the meter indicating the 3800 W reading Find the following: The Input power, P= The power factor, cosɸ= The line current, IL=arrow_forwardering questions and answers /... Question: Two wattmeters in a 3 phase, 3-wire system with a effective line voltage of 120V read 1500W and 500w then inpedence in a balanced delta connectionarrow_forwardA balanced star load with impedances of 6∟45o ohms is connected to a three-phase, four-wire, 208 volt, ABC system. Find the line currents, the neutral current, the power per phase and the total power (S, P, Q).arrow_forward
- Two wattmeters are connected to a 3 phase, 3 wire positive sequence system with a 100 Voutput supplies a balanced delta connected load with impedance of 20 cis 40°. Calculate the: (a) Phase and Line currents(b) Readings of the two Wattmeter(c) Draw the Phasor diagram of the currentsarrow_forwardA balanced Y - connected load having a 25 Ω resistance in each leg is connected to a three -phase , four wires, Y-connected ABC sequence AC generator, if the line volatge EAB=, calculate 1. The phase voltages of the generator 2. The phase voltages of the load 3. The phase currents of the load 4. The line currentsarrow_forwardIn 4 wire power supply, drive the total power for a balanced Y-connected load with the impedance Zo = Z 20 and line voltages Vab=380 230 volt:arrow_forward
- Three identical impedances of 10∟53.1o ohms are connected in delta to a three-phase three-wire 240 volt ABC system. Find the line currents and the total power.arrow_forwardA single wattmeter is connected to measure reactive power of a three-phase, three-wire balanced load. The line current is 17 A and the line voltage is 440 V. Calculate the power factor of the load if the reading of the wattmeter is 4488 VAR.arrow_forwardA three phase transmission line has a resistance of 10 Ω and reactance of 80 Ω per wire. The load current is 90 A and the power factor of the load is 80% lagging. The sending (generator) end voltage in the line is 44,000 V line to line. What is the receiving end voltage? a. 38.4 kV b. 34.3 kV c. 41.2 kV d. 42.3 kVarrow_forward
- A balanced Y load having a load of 3 + j4 Ω in each leg is connected to a three-phase, three wire, Δ-connected generator having a line voltage of 120 V. What Are: Line Voltage (EL), Generator Phase Voltage (), and Load Phase Voltage ()? Load Phase Current (), Generator Phase Current (), and Line Current (IL)? Phase Real Power (P) and Phase Reactive Power (Q)? Total Real Power (P) and Total Reactive Power (Q)?arrow_forwardObtain the readings of two wattmeter’s in a three-phase, three-wire system having effective line voltage of 240 V. The load is a balanced delta connected load impedance of 20 cis 80° ohms.arrow_forwardA 210V, 50 Hz, single phase radial distribution system, the resistance of the wire is 0.0008 ohm/m supply and return. Two loads are connected and it consumes 20 and 15 A respectively and are fed from the cable at distance of 25 and 10 respectively. Calculate the voltage available across load 1 and 2. a- Voltage across load A is, Va= b- Voltage across load B is, Vb=arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License