EBK INTRODUCTORY CIRCUIT ANALYSIS
13th Edition
ISBN: 9780133923872
Author: Boylestad
Publisher: PEARSON CUSTOM PUB.(CONSIGNMENT)
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 24, Problem 35P
To determine
The value of total watts, volt-ampere reactive, volt ampere and power factor
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
1. A three-phase, four wire, ABC system with an a line voltage of 200 Volt, has three impedances of 25
/45ᴼ in a Delta connection. Determine the line current, true power, reactive power and apparent
power and draw the voltage-current phasor diagram.
In the balanced three-phase circuit shown, the current coil of the wattmeter is connected in line aA, and the potential coil of the wattmeter is connected across lines b and c. Show that the wattmeter reading multiplied by 3 equals the total reactive power associated with the load. The phase sequence is positive.
1. a) Find the reading of each wattmeter in the circuit shown if ZA=20 30° Ω, ZB=60 0° Ω, and ZC=40 −30° Ω.
2. b) Show that the sum of the wattmeter readings equals the total average power delivered to the unbalanced three-phase load.
Chapter 24 Solutions
EBK INTRODUCTORY CIRCUIT ANALYSIS
Ch. 24 - A balanced V load having a 10 resistance in each...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - The phase sequence for the Y-Y system in Fig....Ch. 24 - Repeat Problem 4 if each phase impedance are...Ch. 24 - Repeat Problem 4 if each phase impedance is...Ch. 24 - For the system in Fig. 24.43, find the magnitude...Ch. 24 - Computer the magnitude of the voltage EAB for the...Ch. 24 - For the Y-Y system in Fig. 24.45: a. Find the...Ch. 24 - For the Y-Y system of Fig. 24.46 the impedance of...
Ch. 24 - A balanced load having a 20 resistance in each...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - The phase sequence for the Y- system in Fig....Ch. 24 - Repeat Problem 14 if each phase impedance is...Ch. 24 - Repeat Problem 14 if each phase impedance are...Ch. 24 - Prob. 17PCh. 24 - For the connected load in Fig. 24.49: a. Find the...Ch. 24 - A balanced V load having a 30 resistance in each...Ch. 24 - Repeat Problem 19 if each phase impedance is...Ch. 24 - Prob. 21PCh. 24 - Prob. 22PCh. 24 - Prob. 23PCh. 24 - Repeat Problem 22 if each phase impedance is...Ch. 24 - Prob. 25PCh. 24 - Prob. 26PCh. 24 - Prob. 27PCh. 24 - The phase sequence for the - system in Fig....Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Prob. 31PCh. 24 - Prob. 32PCh. 24 - Prob. 33PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 35PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 38PCh. 24 - Prob. 39PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - A balanced, three-phase, -connected load has a...Ch. 24 - A balanced, three-phase, Y-connected load has a...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - The Y-Y system in Fig. 24.53 has a balanced load...Ch. 24 - Prob. 45PCh. 24 - Prob. 46PCh. 24 - Repeat Problem 46 for the network in Fig. 24.47.Ch. 24 - For the three-wire system in Fig. 24.55, properly...Ch. 24 - Sketch three different ways that two wattmeters...Ch. 24 - For the Y- system in Fig. 24.56: Determine the...Ch. 24 - For the system in Fig. 24.57: Calculate the...Ch. 24 - For the three-phase, three-wire system in Fig....
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- (b) Three Impedances each of (10 – j26)Ω are connected in mesh across a three-phase 435V ac supply. Determine the phase current, line current, active power and reactive power drawn from supply. (1)phase current (Ip)? (2)Line current ? (3)real power? (4)reactive power?arrow_forwardA 400V three-phase, four wire system has the following loads connected: Phase 3: load impedance Z3 = 15 – j20 Ω Draw the circuit diagram and determine: The line and phase voltages for phase 3 (including phase angles) The line and phase currents for for phase 3 (including phase angles) The neutral current (including phase angle)arrow_forwardA balanced Y-connected load is connected to 3-phase transmission lines with line-to-line voltages of 21.5 kV. The current in each line is 75 A. What are the phase impedances of the Y-connected load?arrow_forward
- Consider a 3-phase delta-star configuration with a generator and a 3-phase load. The generator supplies voltage of grid-standard 380/220V@50Hz. Each load is (15+15j) Ω.arrow_forwardA three phase transmission line has a resistance of 10 Ω and reactance of 80 Ω per wire. The load current is 90 A and the power factor of the load is 80% lagging. The sending (generator) end voltage in the line is 44,000 V line to line. What is the receiving end voltage? a. 38.4 kV b. 34.3 kV c. 41.2 kV d. 42.3 kVarrow_forwardTwo wattmeters are connected to a 3 phase, 3 wire positive sequence system with a 100 Voutput supplies a balanced delta connected load with impedance of 20 cis 40°. Calculate the: (a) Phase and Line currents(b) Readings of the two Wattmeter(c) Draw the Phasor diagram of the currentsarrow_forward
- A 3 phase 13-KV transmission line delivers 8 MVA of load. The per phase impedance of the line is (0.01 + j 0.05 ) p.u. referred to a 13 – KV, 8 – MVA base. What is the voltage drop across the line?arrow_forward1. Solve the following problem: A THREE-PHASE CIRCUIT WHERE THE BALANCED DELTA LOAD OF 36 + J54 OHMS IS SUPPLIED BY 8,602 OHMS IMPEDANCE CONDUCTORS WITH A PHASE ANGLE OF 54,462 DEGREES. IF THE GENERATOR VOLTAGE IN PHASE B IS 100 VOLTS ANGLE - 120 DEGREES. CALCULATE: A) THE VOLTAGE BC IN LOAD. B) THE POWERS IN THE CONDUCTORS. C) THE POWER TRIANGLE IN THE LOAD.arrow_forwardA balanced star-connected load is supplied from a symmetrical three-phase, 400 V (line-to-line) supply. The current in cach phase is 50 A and lags 30° behind the phase voltage. Calculate: 1) the phase voltage 2) the phase impedance 3) the active and reactive power drawn by the load 4) sketch the phasor diagram showing the phase and line voltages.arrow_forward
- A balanced delta-connected load has phase impedances of 4+j3 Ohms. It is connected to balanced transmission lines, with Vab = 1.5kV @ 15 degrees. a) What is the current through each of the load phases? b) What is the current through each of the transmission lines? c) Which ACSR cable should be used for these transmission lines to give a 20% current rating margin for this load?arrow_forwardA Single-Phase Line has an Impedance of 5.75∠56° Ω and supplies the load with 150 A at 3400 V and 0.84 pf lagging. Calculate the Sending End Voltage and Current in Polar Form (Magnitude and Angle Form).arrow_forwardA 3-phase 415, 50Hz supply is given to delta connected load with impedance (6+j14) ohms. The line current isarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,
Fault Analysis in Power Systems part 1a; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=g8itg4MOjok;License: Standard youtube license