Interpretation Introduction

(a)

Interpretation:

The difference between concentration-sensitive and mass-sensitive detector is to be stated and whether the thermal conductivity detector is mass or concentration sensitive.

Concept introduction:

Thermal conductivity can be defined as the ability of a material to conduct heat.

Interpretation Introduction

(b)

Interpretation:

Whether the atomic emission detector is mass or concentration sensitive.

.

Concept introduction:

Atomic emission occurs when an atom emits some specific wavelengths.

Interpretation Introduction

(c)

Interpretation:

Whether the thermionic detector is mass or concentration sensitive.

Concept introduction:

Thermionic emissions occur when electrons are excited from a heated source.

Interpretation Introduction

(d)

Interpretation:

Whether the electron captive detector is mass or concentration sensitive.

Concept introduction:

The electron capture is the process of making unstable atoms more stable.

Interpretation Introduction

(e)

Interpretation:

Whether the flame photometric detector is mass or concentration sensitive.

Concept introduction:

Flame photometry is utilized for inorganic chemical analysis. It can detect the concentration of some metals like lithium, sodium, calcium and more.

Interpretation Introduction

(f)

Interpretation:

Whether the flame ionization detector is mass or concentration sensitive.

Concept introduction:

Flame ionization detection is a device used to measure the analyte in a gas flow.

Blurred answer
Students have asked these similar questions
What are the parameters that can be used for analytes identification and quantification using Cyclic Voltammetry, respectively?
State the difference between transmittance, absorbance, and molar absorptivity. Which one is proportional to concentration?
The intensities of flame emission lines can be influenced by a variety of instrumentalfactors including flame temperature, flow rate of solution, and nebulizer efficiency. In the flameemission determination of sodium, lithium is often added as an internal standard. The followingemission intensity data were obtained for solutions containing 5.00 ppm Na and 125 ppm Li.5.00 ppm Na 5.9 Intensity for Na 125 ppm Li 9.1 Intensity for LiA solution with an unknown amount of sodium and 125 ppm Li gave a sodium intensity of 4.4 and alithium intensity of 9.5. What is the concentration of sodium in the unknown?
Knowledge Booster
Background pattern image
Similar questions
Recommended textbooks for you
Text book image
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Text book image
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:9781285640686
Author:Skoog
Publisher:Cengage
Text book image
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:9781285686691
Author:Crouch
Publisher:Cengage