PRINCIPLES OF INSTRUMENTAL ANALYSIS
7th Edition
ISBN: 9789353506193
Author: Skoog
Publisher: CENGAGE L
expand_more
expand_more
format_list_bulleted
Question
Chapter 3, Problem 3.24QAP
Interpretation Introduction
Interpretation:
The output voltage of an integrator 1, 3, 5, and 7 s after the start of integration needs to be plotted.
Concept introduction:
The output voltage can be calculated as follows:
Here,
V0 = output voltage
Ri = input resistor
C = feedback capacitor
Vi = input voltage
T = time
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
If Q=96500 Coul and t=8 min ,then I will be
The value of Z for the electrolyte ZnCl2 will be
I=201.04 microamp
Z=65/1
|=12062.5 amp
Z=65/2
I=201.04 amp
Z=65/2
An air-gap parallel plate capacitor whose plates have an area of A=0,38m² are separated by a
distance d=0,61m and are connected to a battery of V₁ = 1,8 V. The space between the parallel
plates is partially filled (x=0,26m) with some material of dielectric constant K=4,56. Find the
electric potential energy stored in the capacitor in terms of permitivity of free-space €0. Express
your answer using 2 decimal places.
4. What is the capacitance of an empty parallel-plate capacitor with metal plates that
each have an area of 1.00m², separated by 1.00 mm?
Chapter 3 Solutions
PRINCIPLES OF INSTRUMENTAL ANALYSIS
Ch. 3 - Prob. 3.1QAPCh. 3 - Prob. 3.2QAPCh. 3 - Prob. 3.3QAPCh. 3 - Prob. 3.4QAPCh. 3 - Prob. 3.5QAPCh. 3 - Prob. 3.6QAPCh. 3 - Prob. 3.7QAPCh. 3 - Prob. 3.8QAPCh. 3 - Prob. 3.9QAPCh. 3 - Prob. 3.10QAP
Ch. 3 - Prob. 3.11QAPCh. 3 - Prob. 3.12QAPCh. 3 - Prob. 3.13QAPCh. 3 - Prob. 3.14QAPCh. 3 - Prob. 3.15QAPCh. 3 - Prob. 3.16QAPCh. 3 - Prob. 3.17QAPCh. 3 - Prob. 3.18QAPCh. 3 - Prob. 3.19QAPCh. 3 - Prob. 3.20QAPCh. 3 - Prob. 3.21QAPCh. 3 - Prob. 3.22QAPCh. 3 - Prob. 3.23QAPCh. 3 - Prob. 3.24QAPCh. 3 - Prob. 3.25QAP
Knowledge Booster
Similar questions
- Electrochemical detection is commonly used in combination capillary electrophoresis systems. This is a type of hydrodynamic voltammetry called flow injection, where it has been shown that ilim a U1/3, where U is the flow rate of the solution. Flow analysis of a urine sample at a thin-layer amperometric detector, with a flow-rate of 1.25mL/min, yielded a limiting current value of 1.6µA for its unknown uric acid content. A larger current of 2.4µA was observed for a sample containing 1 × 10-4 M uric acid and flowing at a rate of 0.9mL/min. Calculate the original concentration of uric acid in the samplearrow_forwardP1B.1 A rotating slotted-disc apparatus consists of five coaxial 5.0 cm diameter discs separated by 1.0 cm, the radial slots being displaced by 2.0° between neighbours. The relative intensities, I, of the detected beam of Kr atoms for two different temperatures and at a series of rotation rates were as follows: v/Hz 20 40 80 100 120 I (40 K) 0.846 0.513 0.069 0.015 0.002 I (100 K) 0.592 0.485 0.217 0.119 0.057 Find the distributions of molecular velocities, f(v,), at these temperatures, and check that they conform to the theoretical prediction for a one-dimensional system for this low-pressure, collision-free system.arrow_forwardThe resistance of a decinormal solution of a salt occupying a volume between Pt electrodes is 1.80 cm apart and 5.4 cm2 in area was found to be 32 ohms. Calculate the equivalent conductance of the solution.arrow_forward
- Design a voltage divider biased common emitter amplifier with a bypassed emitter resistance for a DC supply of Vcc D (18+R)V and a quiescent current of 2mA. The voltage drop across collector should be 40% of DC supply voltage For the given design conditions: R = 02 Compute the circuit resistances.biased values of voltages and currents. Draw the completely labelled circuit diagram.arrow_forwardUse Tafel Equation To Estimate The Current Density (In A/Cm2) For A 2-Electron Electrochemical Reaction At Overpotential Of 100mV. Assume A=0.5, i0=10mA/Cm2, T=300K.arrow_forwardUse the data in Table 19D.1 for the exchange-current density and transfer coefficient for the reaction Fe3+ + e− → Fe2+ on platinum at 25 °C to identify the current density needed to obtain an overpotential of 0.30 V as calculated (i) by using the Butler–Volmer equation, and (ii) by assuming that the current is entirely anodic. Comment on the validity of the latter assumption.arrow_forward
- The resistance of 0.01 M NaCl solution at 25 °C is 200 Ω. The cell constant of conductivity cell is unity. Calculate the molar conductance.arrow_forwardThe resistance of a conductivity cell containing a 0.01 mol KCl solution cm-3 is 150 Ω and the conductivity of this KCl solution is 1.41 × 10-3 Ω-1 cm-1. The same conductivity cell resulting in a resistance of 51.40 Ω for 0.01 HCl solution mol cm-3. Calculate a cell constant and conductivity of the HCl solution.arrow_forwardSuppose the concentration of a solute decays linearly along the length of a container according to c(x) = c0 - αc0x, where c0 is the concentration at x = 0. Calculate the thermodynamic force on the solute at 25 °C and at x = 10 cm and 20 cm given that the concentration falls to 1/2c0 when x = 10 cm. Hint: Start by finding the value of α.arrow_forward
- The exchange-current density for a Pt|Fe3+,Fe2+ electrode is 2.5 mA cm−2. The standard potential of the electrode is +0.77 V. Derive an expression for the current flowing through an electrode of surface area 1.0 cm2 as a function of the potential applied to the electrode; assume standard conditions.arrow_forward(a) A silicon sample maintained at T = 300 K is uniformly doped with Nd = 1016cm-3 donors. Calculate the resistivity of the sample.arrow_forwardThe molar absorptivity for aqueous solutions of phenol at 211 nm is 6.17 × 103 L cm-1 mol-1. Calculate the permissible range of phenol concentrations if the transmittance is to be less than 85% and greater than 7% when the measurements are made in 1.00-cm cells.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning