If, because of some obstruction in a wall space, it is impossible to keep a Type NM cable at least 1¼ in. (32 mm) from the edge of the stud, then it shall be protected by a metal plate at least in. thick.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Q1 (i) What is an LVDT and what is it used for? (ii) Describe the construction features of an LVDT.
Q2 (i) What is a strain gauge and what is it used for? (ii) What is the principle of operation of a strain gauge? (iii) Describe some applications of strain gauges.
17. Sometimes in the manufacture of wire, the wire is slightly larger or smaller than intended. If a wire is measured and found to be 0.079 inch in diameter, for what standard wire size is it intended?
Can a round 4 in. x 1/2 in. box marked as 8 cu in. with cable clamps supplied with 14/2 W/G NM cable be used with a luminaire that has two 18 TFN conductors and a canopy cover?
Chapter 4 Solutions
ELECTRICAL WIRING:RESIDENT.-TEXT (PB)
Ch. 4 - The largest size solid conductor generally...Ch. 4 - What is the minimum branch-circuit wire size that...Ch. 4 - What exceptions, if any, are there to the answer...Ch. 4 - What determines the ampacity of a wire?Ch. 4 - What unit of measurement is used for the diameter...Ch. 4 - What unit of measurement is used for the...Ch. 4 - What is the voltage rating of the conductors in...Ch. 4 - Indicate the allowable ampacity of the following...Ch. 4 - Prob. 9RCh. 4 - What are the colors of the conductors in...
Ch. 4 - For nonmetallic-sheathed cable, may the...Ch. 4 - Prob. 12RCh. 4 - Under what condition may nonmetallic-sheathed...Ch. 4 - a. What is the maximum distance permitted between...Ch. 4 - Prob. 15RCh. 4 - Prob. 16RCh. 4 - Prob. 17RCh. 4 - Prob. 18RCh. 4 - Prob. 19RCh. 4 - Circle the correct answer to the following...Ch. 4 - When running Type NM cable through a bored hole in...Ch. 4 - Where is the main service-entrance panel located...Ch. 4 - Is it permitted to use flexible metal conduit over...Ch. 4 - Liquidtight flexible metal conduit may serve as a...Ch. 4 - It is permissible for an electrician to connect...Ch. 4 - Terminals of switches and receptacles marked...Ch. 4 - Wire connectors marked AL/CU are suitable for use...Ch. 4 - A wire connector bearing no marking or reference...Ch. 4 - When Type NM cable is run through a floor, it must...Ch. 4 - When nonmetallic-sheathed cables are bunched or...Ch. 4 - In diagrams A and B, nonmetallic-sheathed cable is...Ch. 4 - The marking on the outer jacket of a...Ch. 4 - A 120-volt branch circuit supplies a resistive...Ch. 4 - In problem 35, it is desired to keep the voltage...Ch. 4 - Prob. 37RCh. 4 - The allowable ampacity of a 4 AWG THHN from Table...Ch. 4 - If, because of some obstruction in a wall space,...Ch. 4 - The recessed fluorescent luminaires installed in...Ch. 4 - Prob. 41RCh. 4 - What size overcurrent device protects the...Ch. 4 - May the 20-ampere small-appliance branch circuits...Ch. 4 - A 30-ampere branch circuit is installed for an...Ch. 4 - In many areas, metal framing members are being...Ch. 4 - Are set screwtype connectors permitted to be used...Ch. 4 - Most armored cable today has 90C conductors. What...Ch. 4 - If you saw two different types of SE cables, how...Ch. 4 - Circle the correct answer defining the type of...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
When travelers from the USA and Canada visit Europe, they encounter a different power distribution system. Wall...
Electric machinery fundamentals
Does the severity of an electric shock increase ordecrease with eh of the following changes? a. A decrease in t...
Electric Motors and Control Systems
What is the color code for a 365- five-band precision resistor with a tolerance of 5 percent?
ELECTRICITY FOR TRADES (LOOSELEAF)
How many coulombs do 93.8 1016 electrons represent?
Principles Of Electric Circuits
For the “tank” circuit in Fig. 14.79, find the resonant frequency.
Figure 14.79
For Probs. 14.39, 14.71, and 1...
Fundamentals of Electric Circuits
Explain the main function of each of the following major components of a PLC: a. Processor module (CPU) b. I/O ...
Programmable Logic Controllers
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- When Type NM cable is run through a floor, it must be protected by at least ______ in. (_____ mm) of ________arrow_forwardWhen running Type NM cable through a bored hole in a stud, the nearest edge of the bored hole shall not be less than ________ in. from the face of the stud unless the cable is protected by a 116 in. (1.6 mm) metal steel plate(s).arrow_forward3. A 2-wire d.c. distributor AB 500 metres long is fed from point .4 and is loaded as under: Distance from feeding point.4 (in metres) Load (amperes) If the specific resistance of copper is 1-7x 10 Sm what must be the cross-section of each wire in order that the voltage drop in the dismbutor shall not exceed 10 volts ? 100 300 400 500 20 40 40 50 [1 734 cm]arrow_forward
- 3. A 2-wire d.c. distributor AB 500 metres long is fed from point A and is loaded as under : Distance from feeding point A (in metres) 100 300 400 500 Load (amperes) If the specific resistance of copper is 1-7 x 10 Qm, what must be the cross-section of each wire in order that the voltage drop in the distributor shall not exceed 10 volts ? 20 40 40 50 [1-734 cm]arrow_forwardHow IGBT is classified based on its layer of construction? Compare the characteristics of the device (Minimum Four Points) with cross sectional views of the type.arrow_forwardWhat is the advantage of using erasing shieldarrow_forward
- I have an O Gauge track and would like to convert it into a “sensored” track. Additionally, I would like to connect that track to an ESP-WROOM-32 board that should flash an LED whenever the track detects a non-moving train. Please list all the components (and how many of each) needed. Also, what’s the procedure for connecting the components?arrow_forward3. A 2-wire d.c. distributor A B 500 metres long is fed from point A and is loaded as under : Distance from feeding point A (in metres) Load (amperes) If the specific resistance of copper is 1-7x 10* 2m, what must be the cross-section of each wire in order that the voltage drop in the distributor shall not exceed 10 volts ? 100 300 400 500 20 40 40 50 [1-734 cm³]arrow_forwardA semiconductor is a material that has _____ energy band gap. a)no b)wide c)narrow d)nucleararrow_forward
- what is error in mesurement system? Also discuss its typesarrow_forwarda) Find the value of resistor using colour code (Brown-Orange-Gold-Silver). b) Suppose the measured value of resistor using DMM is 1.9 N. Is the within tolerance limit of resistor? c) Find the absolute and relative error of colour coded value of resistance and measured resistance using DMM.arrow_forwarda) Find the value of resistor using colour code (Brown-Orange-Gold-Silver). b) Suppose the measured value of resistor using DMM is 1.9 2. Is the within tolerance limit of resistor? c) Find the absolute and relative error of colour coded value of resistance and measured resistance using DMM.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License