Textbook Question
Chapter 5, Problem 5.10P
The 500-kV, 60-Hz, three-phase line in Problems 4.20 and 4.41 has a 180-km length and delivers 1600 M W at 475 kv and at 0.95 power factor leading to the receiving end at full load. Using the nominal
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The 100-km,230-kV, 60Hz. three-phase line in Problems 4.18 and 4.39 delivers 300MVA at 218kV to the receiving end at full load. Using the nominal Π circuit, calculate the ABCD parameters, sending-end voltage, and percent voltage regulation when the receiving-end power factor is (a) 0.9 lagging, (b) unity, and (c) 0.9 leading, Assume a 50°C conductor temperature to determine the resistance of this line.
Please answer in short and dont copy i will like....
A. For underground and underwater transmission, why are line losses for HVDC cables lower than those of ac cables with similar capacity?
B. What are the benefits of controlling of power flows on individual lines? What are the risks?
What is The effect of increasing VS in power transmission line performance study?
Chapter 5 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 5 - Representing a transmission line by the two-port...Ch. 5 - The maximum power flow for a lossy line is...Ch. 5 - Prob. 5.21MCQCh. 5 - A 30-km, 34.5-kV, 60-Hz, three-phase line has a...Ch. 5 - A 200-km, 230-kV, 60-Hz, three-phase line has a...Ch. 5 - The 100-km, 230-kV, 60-Hz, three-phase line in...Ch. 5 - The 500-kV, 60-Hz, three-phase line in Problems...Ch. 5 - A 40-km, 220-kV, 60-Hz, three-phase overhead...Ch. 5 - A 500-km, 500-kV, 60-Hz, uncompensated three-phase...Ch. 5 - The 500-kV, 60-Hz, three-phase line in Problems...
Ch. 5 - A 350-km, 500-kV, 60-Hz, three-phase uncompensated...Ch. 5 - Rated line voltage is applied to the sending end...Ch. 5 - A 500-kV, 300-km, 6()-Hz, three-phase overhead...Ch. 5 - The following parameters are based on a...Ch. 5 - Consider a long radial line terminated in its...Ch. 5 - For a lossless open-circuited line, express the...Ch. 5 - A three-phase power of 460 MW is transmitted to a...Ch. 5 - Prob. 5.55PCh. 5 - Consider the transmission line of Problem 5.18....Ch. 5 - Given the uncompensated line of Problem 5.18, let...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The 100-km, 230-kV, 60-Hz, three-phase line in Problems 4.18 and 4.39 delivers 300 M VA at 218 kv to the receiving end at full load. Using the nominal circuit, calculate the ABCD parameters, sending-end voltage, and percent voltage regulation when the receiving-end power factor is (a) 0.9 lagging, (b) unity, and (c) 0.9 leading. Assume a 50C conductor temperature to determine the resistance of this line.arrow_forwardFigure 4.34 shows double-circuit conductors' relative positions in segment I of transposition of a completely transposed three-phase overhead transmission line. The inductance is given by L=2107lnGMDGMRH/m/phase Where GMD=(DABeqDBCeqDACeq)1/3 With mean distances defined by equivalent spacings DABeq=(D12D12D12D12)1/4DBCeq=(D23D23D23D13)1/4DACeq=(D13D13D13)1/4 And GMR=[ (GMR)A(GMR)B(GMR)C ]1/3 with phase GMRs defined by (GMR)A=[ rD11 ]1/2;(GMR)B=[ rD22 ]1/2;(GMR)C=[ rD33 ]1/2 and r is the GMR of phase conductors. Now consider a 345-kV, three-phase, double-circuit line with phase-conductors GMR of 0.0588 ft and the horizontal conductor configuration shown in Figure 4.35. Determine the inductance per meter per phase in Henries (H). Calculate the inductance of just one circuit and then divide by 2 to obtain the inductance of the double circuit.arrow_forwardThe capacitance of a single-circuit, three-phase transposed line with the configuration shown in Figure 4.38, including ground effect, and with conductors not equilaterally spaced is given by C20lnDeqrlnHmH8 F/m line-to-neutral where Deq=D12D23D133=GMD r= conductors outside radiusHm=(H12H23H13)1/3HS=(H1H2H3)1/3 Now consider Figure 4.39 in which the configuration of a three-phase, single circuit, 345-kV line with conductors having an outside diameter of 1.065 in. is shown. Determine the capacitance to neutral in F/m, including the ground effect. Next, neglecting the effect of ground, see how the value changes.arrow_forward
- The maximum power flow for a lossy line is somewhat less than that for a lossless line. True Falsearrow_forwardThe following parameters are based on a preliminary line design: per unitVS=1.0, VR=0.9 per unit, =5000km,Zc=320,=36.8. A three-phase power of 700 MW is to be transmitted to a substation located 315 km from the source of power. (a) Determine a nominal voltage level for the three-phase transmission line, based on the practical line-loadability equation. (b) For the voltage level obtained in part (a), determine the theoretical maximum power that can be transferred by the line.arrow_forwardThe 500-kV, 60-Hz, three-phase line in Problems 4.20 and 4.41 has a 300-km length. Calculate: (a) Zc, (b) (l), and (c) the exact ABCD parameters for this line. Assume a 50C conductor temperature.arrow_forward
- A 200-km, 230-kV, 60-Hz, three-phase line has a positive-sequence series impedance z=0.08+j0.48/km and a positive-sequence shunt admittance y=j3.33106S/km. At full load, the line delivers 250 MW at 0.99 p.f. lagging and at 220 k V. Using the nominal circuit, calculate: (a) the ABCD parameters, (b) the sending-end voltage and current, and (c) the percent voltage regulation.arrow_forwardFor either single-phase two-wire line or balanced three-phase three-wire line with equal phase spacing D and with conductor radius r, the capacitance (line-to-neutral) in F/m is given by Can=.arrow_forwardA three-phase overhead transmission line is designed to deliver 190.5 M VA at 220 kV over a distance of 63 km, such that the total transmission line loss is not to exceed 2.5 of the rated line MVA. Given the resistivity of the conductor material to be 2.84108-m, determine the required conductor diameter and the conductor size in circular mils. Neglect power losses due to insulator leakage currents and corona.arrow_forward
- Discuss three negative effects that result from the effects of the construction of a transmission line (during its construction and after)arrow_forwardExplain the difference between AC versus DC transmission line design, reliability, applications and benifits.arrow_forwardWrite down the importance of transmission line constants.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Power System Stability in C# Part 1: Fundamentals of Stability Analysis; Author: EETechStuff;https://www.youtube.com/watch?v=SaT9oWcHgKw;License: Standard Youtube License