Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
error_outline
This textbook solution is under construction.
Students have asked these similar questions
1.
What is the necessary condition for matching transmission lines? In addition, what is a micro strip line?
2.
For a distortion less line α = 0.02dB/m, Z0 (R0) = 60Ω and C = 0.2nF/m. Find the resistance and velocity of wave propagation. [Do not forget the units.]
3.
For a finite lossless transmission line with open-circuit termination, sketch Xio vs l. Indicate where the sketch is inductive and capacitive.
An extra high voltage transmission line of length 300 km can be approximated by a lossless line having propgation constant is 0.00127 rad/km. The percentage ratio of line length to wave length will nearly by ?
The capacitance per unit length and the inductance per unit length for a lossless transmission line are 0.1 F/m and 20 H/m respectively. What will be the characteristic impedance of the line?
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- An extra high voltage transmission line of length 300 km can be approximate by a lossless line having propogation constant β= 0.00127 radians per km. Then the percentage ratio of line length to wavelength will be given by ??arrow_forwardA three-phase power of 460 MW is transmitted to a substation located 500 km from the source of power. With VS=1. per unit, VR=0.9 per unit, =5000 km, Zc=500, and =36.87, determine a nominal voltage level for the lossless transmission line based on Eq. (5.4.29) of the text. Using this result, find the theoretical three-phase maximum power that can be transferred by the lossless transmission line.arrow_forwardThe capacitance per unit length and the characteristic impedance of a lossless Transmission line are C and Z0 respectively. Express the velocity of travelling wave on the transmission line in terms of the two given parameters above.arrow_forward
- A three-phase power of 460 MW is transmitted to a substation located 500 km from the source of power. With VS=1 per unit, VR=0.9 per unit, λ =5000 km, Zc =500 V, and δ=36.878, determine a nominal voltagen level for the lossless transmission line based on Eq. (5.4.29) of the text. Using this result, find the theoretical three-phase maximum power that can be transferred by the lossless transmission line.arrow_forwardA 50-ohm lossless transmission line is terminated by a 100-ohm resistive load and is operated at 100 MHz. At an electrical length of 0.8 wavelengths, what is input admittance?arrow_forwardWhat is meant by transmission line and Attenuation in transmission lines and why it is happen? justify your answer with suitable examples and figures?arrow_forward
- The capacitance per unit length and the characteristic impedance of a lossless transmission line is C and Zo, respectively. Find the velocity of a travelling wave on the transmission line.arrow_forwardA microstrip line is composed of zero thickness copper conductors on a substrate having εr = 8.4, tan = 0.0005 and thickness 1.5 mm. if the line width is 0.5 mm,and operated at 6Ghz, determine the characteristic impedance.arrow_forwardA lossless transmission with characteristic impedance of ?0 = 100Ω and length = 52cmThe line was terminated with a load of ?? = 30 + ?50Ω. According to what is given, a) The reflection coefficient in the load and the voltage standing wave ratio on the line (GDDO)Find out.b) Find the impedance and admittance at the line input. (for ? = 750???)c) For ? = 750???, the impedance and admittance values 2cm away from the load.(It will be assumed that = ?0.)arrow_forward
- For a lossless trabsmisison line, the characteristic impedance is 80 ohm. If the capacitance per unit length is 1.5 mh/m then what will be the inductance per unit length.arrow_forwardA 50Ω lossless transmission line is terminated with a load impedance valued ZL = RL + jXL.According to what is given, a) RL for Voltage Standing Wave Ratio to be 2What should be the relationship between XL and?b) If RL = 100Ω, find the value of XL.c) Find the voltage minimum point closest to the load on the line.arrow_forwardEstimate the characteristic impedance and propagation constant of a lossless transmission line in terms of the transmission line parameters (Resistance per unit length etc.).arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
How do Electric Transmission Lines Work?; Author: Practical Engineering;https://www.youtube.com/watch?v=qjY31x0m3d8;License: Standard Youtube License