![EBK 3N3-EBK: INDUSTRIAL MOTOR CONTROL](https://www.bartleby.com/isbn_cover_images/9780176919962/9780176919962_largeCoverImage.gif)
EBK 3N3-EBK: INDUSTRIAL MOTOR CONTROL
7th Edition
ISBN: 9780176919962
Author: Herman
Publisher: VST
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 54, Problem 3RQ
Why are the contacts used to represent stop buttons and overload contacts programmed normally open?
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Want to see the full answer?
Check out a sample textbook solution![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
1.
A mixing vat has an inlet valve, an outlet valve, a mixing motor, and a single level detecting switch (Figure 1).
Both valves are opened by solenoids. The level switch closes when the vat is full and stays closed until the vat is
empty. Draw a PLC ladder logic diagram and provide the allocation list to do the
following:
a. When the start button is pushed, the inlet valve opens until the vat is full.
b. The mixer motor comes on for 5 min.
c. The outlet valve opens until the vat is empty.
(closed)
Level switch
Motor
Inlet valve
Outlet valve
Float
Vat
Figure 1
Bohar model Gizmo answer keys
In what ways do controllers for various devices aid in operation?
Chapter 54 Solutions
EBK 3N3-EBK: INDUSTRIAL MOTOR CONTROL
Ch. 54 - Why are NEMA symbols representing such components...Ch. 54 - Explain how to program an internal relay into the...Ch. 54 - Why are the contacts used to represent stop...Ch. 54 - Why is the output I/O used to energize a motor...Ch. 54 - Prob. 5RQCh. 54 - When programming in Boolean, what command is used...Ch. 54 - When programming in Boolean, what command is used...Ch. 54 - When programming in Boolean, what command is used...Ch. 54 - Why are the numbers 8 and 9 not used in an OCTAL-...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Name the four basic sections of a programmable logic controller.arrow_forwardAn emergency stop system is to be designed for a certain automatic production machine. A single “start” button is used to turn on the power to the machine at the beginning of the day. In addition, there are two “stop” buttons located at two locations on the machine, either of which can be pressed to immediately turn off power to the machine. Let X1 = start button (normally open), X2 = stop button 1 (normally closed), X3 = stop button 2 (normally closed), and Y = power-to-machine. (a) Construct the truth table for this system. (b) Write the Boolean logic expression for the system. (c) Construct the ladder logic diagram for the systemarrow_forwardFor a FANCU Robot What position should the Teach pendant Enable/Disable switch be in for manual operation?arrow_forward
- What is the purpose of the key switch located on the front of the CPU in many programmable logic controllers?arrow_forwardan automatic door mechanism where when a specific sensor on top detects a user approaching, where the doors should open and the door is known to be open or closed through the limit switches found below, LS1 and LS2. draw flowchart and ladder diagram.arrow_forwardFlash type ADC gives highest conversion rate. Select one: O True O False The close loop control system is also known as control system.arrow_forward
- Many control systems have operating modes that can be accessed with a scan tool to control the operation of an output. What are the names of the two most common modes for controlling outputs?arrow_forward17- The memory unit of PLC is used to write the program to control output device. Select one: True Falsearrow_forwardChapter 18 Controlling a Preumatic System 461 Timing volume reservoir Goodheart-Willcox Publisher Figure 18-31, Timing-volume reservoirs allow ontrol of the sequence of a circuit using pilot-activated directional control valves.arrow_forward
- Why are normally closed components such as STOP push buttons programmed normally open instead of normally closed when entering a program into the memory of a PLC?arrow_forwardFOR A FANUC 6 axis robot What is the purpose of the Deadman’s switch?arrow_forwardFor a Fanuc Robot What button on the teach pendant selects the modes such as World and Joint?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage LearningPrecision Machining Technology (MindTap Course Li...Mechanical EngineeringISBN:9781285444543Author:Peter J. Hoffman, Eric S. Hopewell, Brian JanesPublisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781337798686/9781337798686_smallCoverImage.jpg)
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781133612315/9781133612315_smallCoverImage.gif)
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781285444543/9781285444543_smallCoverImage.gif)
Precision Machining Technology (MindTap Course Li...
Mechanical Engineering
ISBN:9781285444543
Author:Peter J. Hoffman, Eric S. Hopewell, Brian Janes
Publisher:Cengage Learning
The Robot Revolution: The New Age of Manufacturing | Moving Upstream; Author: Wall Street Journal;https://www.youtube.com/watch?v=HX6M4QunVmA;License: Standard Youtube License