Chapter 6, Problem 6.80P
The head-versus-flow-rate characteristics of a centrifugal pump are shown in Fig. P6.80. If this pump drives water at 20°C through 120 m of 30-cm-diameter cast iron pipe, what will be the resulting flow rate, in m3/s?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A pelton wheel is supplied with water under a head of 100 m
at the rate 1000 litres/s. The bucket deflects the jet through
an angle of 160°. The mean speed of bucket is 20 m/s.
Find :
Mass flow rate of water
(i)
(ii) Velocity of jet
(iii) Power output
H.
V2
V2
160°
C
$ = 20°
A
V1 =Vw1
Q2/When the pump in Fig. below draws 220 m³/h of water at 20°C from the
reservoir, the total friction head loss is 5 m. The flow discharges through a nozzle
to the atmosphere. Estimate the pump power in kW delivered to the water.
D= 12 cm
D= 5 cm
V,
2 m
Pump
6 m
Water
(B) Two similar centrifugal pumps are connected in series. The theoretical head-
discharge relation of Pump#1 is given by: h, = 5.3 – 0.58Q and that of Pump#2 is
given by: h, = 7.7 + 0.22Q. At a specific operation conditions, the head of these
combined pumps is 12 m. Estimate the followings:
(i) The head of each pump
(ii) If the flow out of this system is completely blocked while the two pumps still
running, what is the resulting total head of the system?
(iii) If the two pumps rotates with same speed, how many pump#2 is bigger than
pump#1?
Chapter 6 Solutions
FLUID MECHANICS W/ONLINE ACCESS CODE
Ch. 6 - Prob. 6.1PCh. 6 - The present pumping rate of crude oil through the...Ch. 6 - The Keystone Pipeline in the chapter opener photo...Ch. 6 - For flow of SAE 30 oil through a 5-cm-diameter...Ch. 6 - In flow past a body or wall, early transition to...Ch. 6 - P6.6 For flow of a uniform stream parallel to a...Ch. 6 - SAE 10W30 oil at 20°C flows from a tank into a...Ch. 6 - P6.8 When water at 20°C is in steady turbulent...Ch. 6 - A light liquid 950kg/m3 flows at an average...Ch. 6 - Water at 20°C flows through an inclined...
Ch. 6 - Water at 20°C flows upward at 4 m/s in a...Ch. 6 - Prob. 6.12PCh. 6 - Prob. 6.13PCh. 6 - Prob. 6.14PCh. 6 - Prob. 6.15PCh. 6 - Prob. 6.16PCh. 6 - P6.17 A capillary viscometer measures the time...Ch. 6 - P6.18 SAE 50W oil at 20°C flows from one tank to...Ch. 6 - Prob. 6.19PCh. 6 - The oil tanks in Tinyland are only 160 cm high,...Ch. 6 - Prob. 6.21PCh. 6 - Prob. 6.22PCh. 6 - Prob. 6.23PCh. 6 - Prob. 6.24PCh. 6 - Prob. 6.25PCh. 6 - Prob. 6.26PCh. 6 - Let us attack Prob. P6.25 in symbolic fashion,...Ch. 6 - Prob. 6.28PCh. 6 - Prob. 6.29PCh. 6 - Prob. 6.30PCh. 6 - A laminar flow element (LFE) (Meriam Instrument...Ch. 6 - SAE 30 oil at 20°C flows in the 3-cm.diametcr pipe...Ch. 6 - Prob. 6.33PCh. 6 - Prob. 6.34PCh. 6 - In the overlap layer of Fig. 6.9a, turbulent shear...Ch. 6 - Prob. 6.36PCh. 6 - Prob. 6.37PCh. 6 - Prob. 6.38PCh. 6 - Prob. 6.39PCh. 6 - Prob. 6.40PCh. 6 - P6.41 Two reservoirs, which differ in surface...Ch. 6 - Prob. 6.42PCh. 6 - Prob. 6.43PCh. 6 - P6.44 Mercury at 20°C flows through 4 m of...Ch. 6 - P6.45 Oil, SG = 0.88 and v = 4 E-5 m2/s, flows at...Ch. 6 - Prob. 6.46PCh. 6 - Prob. 6.47PCh. 6 - Prob. 6.48PCh. 6 - Prob. 6.49PCh. 6 - Prob. 6.50PCh. 6 - Prob. 6.51PCh. 6 - Prob. 6.52PCh. 6 - Water at 2OC flows by gravity through a smooth...Ch. 6 - A swimming pool W by Y by h deep is to be emptied...Ch. 6 - Prob. 6.55PCh. 6 - Prob. 6.56PCh. 6 - Prob. 6.57PCh. 6 - Prob. 6.58PCh. 6 - P6.59 The following data were obtained for flow of...Ch. 6 - Prob. 6.60PCh. 6 - Prob. 6.61PCh. 6 - Water at 20°C is to be pumped through 2000 ft of...Ch. 6 - Prob. 6.63PCh. 6 - Prob. 6.64PCh. 6 - Prob. 6.65PCh. 6 - Prob. 6.66PCh. 6 - Prob. 6.67PCh. 6 - Prob. 6.68PCh. 6 - P6.69 For Prob. P6.62 suppose the only pump...Ch. 6 - Prob. 6.70PCh. 6 - Prob. 6.71PCh. 6 - Prob. 6.72PCh. 6 - Prob. 6.73PCh. 6 - Prob. 6.74PCh. 6 - Prob. 6.75PCh. 6 - P6.76 The small turbine in Fig. P6.76 extracts 400...Ch. 6 - Prob. 6.77PCh. 6 - Prob. 6.78PCh. 6 - Prob. 6.79PCh. 6 - The head-versus-flow-rate characteristics of a...Ch. 6 - Prob. 6.81PCh. 6 - Prob. 6.82PCh. 6 - Prob. 6.83PCh. 6 - Prob. 6.84PCh. 6 - Prob. 6.85PCh. 6 - SAE 10 oil at 20°C flows at an average velocity of...Ch. 6 - A commercial steel annulus 40 ft long, with a = 1...Ch. 6 - Prob. 6.88PCh. 6 - Prob. 6.89PCh. 6 - Prob. 6.90PCh. 6 - Prob. 6.91PCh. 6 - Prob. 6.92PCh. 6 - Prob. 6.93PCh. 6 - Prob. 6.94PCh. 6 - Prob. 6.95PCh. 6 - Prob. 6.96PCh. 6 - Prob. 6.97PCh. 6 - Prob. 6.98PCh. 6 - Prob. 6.99PCh. 6 - Prob. 6.100PCh. 6 - Prob. 6.101PCh. 6 - *P6.102 A 70 percent efficient pump delivers water...Ch. 6 - Prob. 6.103PCh. 6 - Prob. 6.104PCh. 6 - Prob. 6.105PCh. 6 - Prob. 6.106PCh. 6 - Prob. 6.107PCh. 6 - P6.108 The water pump in Fig. P6.108 maintains a...Ch. 6 - In Fig. P6.109 there are 125 ft of 2-in pipe, 75...Ch. 6 - In Fig. P6.110 the pipe entrance is sharp-edged....Ch. 6 - For the parallel-pipe system of Fig. P6.111, each...Ch. 6 - Prob. 6.112PCh. 6 - Prob. 6.113PCh. 6 - Prob. 6.114PCh. 6 - Prob. 6.115PCh. 6 - Prob. 6.116PCh. 6 - Prob. 6.117PCh. 6 - Prob. 6.118PCh. 6 - Prob. 6.119PCh. 6 - Prob. 6.120PCh. 6 - Prob. 6.121PCh. 6 - Prob. 6.122PCh. 6 - Prob. 6.123PCh. 6 - Prob. 6.124PCh. 6 - Prob. 6.125PCh. 6 - Prob. 6.126PCh. 6 - Prob. 6.127PCh. 6 - In the five-pipe horizontal network of Fig....Ch. 6 - Prob. 6.129PCh. 6 - Prob. 6.130PCh. 6 - Prob. 6.131PCh. 6 - Prob. 6.132PCh. 6 - Prob. 6.133PCh. 6 - Prob. 6.134PCh. 6 - An airplane uses a pitot-static tube as a...Ch. 6 - Prob. 6.136PCh. 6 - Prob. 6.137PCh. 6 - Prob. 6.138PCh. 6 - P6.139 Professor Walter Tunnel needs to measure...Ch. 6 - Prob. 6.140PCh. 6 - Prob. 6.141PCh. 6 - Prob. 6.142PCh. 6 - Prob. 6.143PCh. 6 - Prob. 6.144PCh. 6 - Prob. 6.145PCh. 6 - Prob. 6.146PCh. 6 - Prob. 6.147PCh. 6 - Prob. 6.148PCh. 6 - Prob. 6.149PCh. 6 - Prob. 6.150PCh. 6 - Prob. 6.151PCh. 6 - Prob. 6.152PCh. 6 - Prob. 6.153PCh. 6 - Prob. 6.154PCh. 6 - Prob. 6.155PCh. 6 - Prob. 6.156PCh. 6 - Prob. 6.157PCh. 6 - Prob. 6.158PCh. 6 - Prob. 6.159PCh. 6 - Prob. 6.160PCh. 6 - Prob. 6.161PCh. 6 - Prob. 6.162PCh. 6 - Prob. 6.163PCh. 6 - Prob. 6.1WPCh. 6 - Prob. 6.2WPCh. 6 - Prob. 6.3WPCh. 6 - Prob. 6.4WPCh. 6 - Prob. 6.1FEEPCh. 6 - Prob. 6.2FEEPCh. 6 - Prob. 6.3FEEPCh. 6 - Prob. 6.4FEEPCh. 6 - Prob. 6.5FEEPCh. 6 - Prob. 6.6FEEPCh. 6 - Prob. 6.7FEEPCh. 6 - Prob. 6.8FEEPCh. 6 - Prob. 6.9FEEPCh. 6 - Prob. 6.10FEEPCh. 6 - Prob. 6.11FEEPCh. 6 - Prob. 6.12FEEPCh. 6 - Prob. 6.13FEEPCh. 6 - Prob. 6.14FEEPCh. 6 - Prob. 6.15FEEPCh. 6 - Prob. 6.1CPCh. 6 - Prob. 6.2CPCh. 6 - Prob. 6.3CPCh. 6 - Prob. 6.4CPCh. 6 - Prob. 6.5CPCh. 6 - Prob. 6.6CPCh. 6 - Prob. 6.7CPCh. 6 - Prob. 6.8CPCh. 6 - Prob. 6.9CPCh. 6 - A hydroponic garden uses the 10-m-long...Ch. 6 - It is desired to design a pump-piping system to...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Air flows in a horizontal duct. At section 1 of the duct, the velocity is 1.2 m/s, pressure is 10 Pag, and duct diameter is 33 cm. Downstream of the flow is section 2 where the duct diameter is 18 cm. Taking the density of the air as 1.225 kg/m^3, and acceleration due to gravity as 9.8066 m/s^2, calculate the pressure at section 2 in Pag. Round your answer to 3 decimal places. Add your answerarrow_forward... height Fire hoses used in major structural fires have an inside diameter of 6.40 cm. Suppose such a hose carries a flow of 43 L/s. The hose rises up 13.3 m along a ladder to a nozzle having an inside diameter of 3.00 cm. What is the starting pressure at the fire truck? Use p=1000 kg/m³ and g =9.8 m/s? Answer in KPa. No label, no unit, number only.arrow_forwardThe head-versus-flow-rate characteristics of a centrifugalpump are shown in Fig.. If this pump drives water at20°C through 120 m of 30-cm-diameter cast iron pipe,what will be the resulting flow rate, in m3/s?arrow_forward
- A fan delivers 5.794 m^3/sec at a static pressure of 5.106 cm of water when operating at a speed of 492.992 rpm. The power input required is 4.536 kW. If 8.404 m^3/s are desired in the same fan and installation, find the new operating speed in rpm Answer in whole numberarrow_forwardPAY ATTENTION TO THE QUESTION : What is the resulting flow rate in the system if three pumps are used in parallel? (a) 0.483 m^3/s (b) 0.364 m^3/s (c) 0.333 m^3/s (d) 0.563 m^3/s 1. The Head -flowrate curve for a centrifugal pump is given by: HP = 28 -30Q2 Where, HP is in meter and Q is in m3/s . This pump is used to pump water for a system with the following (H-Q) curve: HS = 8 + 150Q2 Where, HS is in meter and Q is in m3/s . IT SAYS : if theee pumps are used in parallel PAY ATTENTION Multiple choice choose correct answerarrow_forwardQ.4 A horizontal - shaft centrifugal pump lifts water at 65°C. The suction nozzle is one meter below pump centerline. The pressure at this point equals 200 kPa gauge and velocity is 3 m/s. Steam tables show saturation pressure at 65°C is 25 kPa, and specific volume of the saturated liquid is 0.001020 m/kg. The pump Net Positive Suction Head (NPSH) in meters isarrow_forward
- A centrifugal pump delivers 1.8m3 water against a head of 30m when rotating at 1200rpm. The diameter of its impeller is 45cm. If a pump with the same specific speed is to discharge 6.0m3/sec at 1100rpm, what is its impeller diameter? ANSWER: 69.2cmarrow_forwardA centrifugal pump having four stages in parallel delivers 12 kiloLiters per minute of liquid against a head of 25m. The diameter of the impeller being 24 cm has a speed of 1800 rpm. A pump is to be made up with a number of stages in series. In similar construction to that of the first pump to run at 1250 rpm and to deliver 15 kiloLiters/min against a total head of 250 m, find the number of stages required in this case. Select the correct response: 2. 4) 3.arrow_forwardExample 3: A pipe 50 cm in diameter carries water (10 °C) at a rate of 0.5 m³/s. A pump in the pipe is used to move the water from an elevation of 30 m to 40 m. The pressure at section 1 is 70 kPa gage, and the pressure at section 2 is 350 kPa gage. What power in kilowatts and in horsepower must be supplied to the flow by the pump? Assume h₁ = 3 m of water and α₁ = α₂ = 1. Water is being pumped through a system. Z₁ = 30 m P1 = 70 kPa gage a1 1.0 Pump Z₂ = 40 m P2 = 350 kPa gage α₂ = 1.0 Pipe D = 0.5 m Head loss in pipe = 3 m Water Q=0.5 m³/s Properties: Water (10°C, 1 atm, Table A.5): y = 9810 N/m³arrow_forward
- 2. A fan discharges 265 cu.m/min of air through a duct of 92 cm in diameter against a static pressure of 0.022 m of water. The fluid density is 995 kg/cu.m., the air temperature is 29°C and the barometric pressure reading is 730 mm Hg. If the power input to the fan is measured 3.5 hp, what are the total and static fan efficiencies?arrow_forwardPropose a centrifugal pump (brand and model) to transport 10 L/s of a fluid with a density of 1500 kg/m3 from a tank located on the first floor to a reactor on the second floor of the plant (8 meters in height). The reactor's operating pressure is 30 psig; the fluid is at 20 °C, and its viscosity is 15 cp. The pipeline on the pump discharge is 30 meters long (considering accessories are included). Neglect pressure losses in the pump suction. Propose the pipe diameter, schedule 40, commercial steel. Make any necessary assumptions. Select a pump capable of delivering a maximum flow of 15 L/s (remember that normal operation will be at 10 L/s) and discuss the price paid for this condition. Provide a copy of the pump curve indicating the operating point. Also, calculate the power consumption of the pump.arrow_forwardExample: Two centrifugal pumps are connected in parallel in a given pumping system. Plot total head Ah against capacity Q pump and system curves for both pumps running on the basis of the following data operating data for pump 1 Ah, m 40 35 30 25 Qs, m³/h 169 209 239 265 operating data for pump 2 Ah, m 40 35 30 25 Qs, m³/h 0 136 203 267 Data for system Ah, m 20 20 25 30 35 Qs, m³/h 0 244 372 470arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Fluid Mechanics - Viscosity and Shear Strain Rate in 9 Minutes!; Author: Less Boring Lectures;https://www.youtube.com/watch?v=_0aaRDAdPTY;License: Standard youtube license