To determine
Find the class type and the protection type of the fluorescent ballasts for all indoor applications.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
what section of the code prohibits supporting telephone wires from raceways that contain light or power conductors.
When calculating a dwelling lighting load on the "volt-ampere per ft" basis, the receptacle load used for floor lamps, table lamps, and so forth are
QUESTION 25
Type TC cable shall not be _____.
a.
installed where it will be exposed to physical damage
b.
all of these
c.
installed outside of a race-way or cable tray system, unless permitted in 336.10(4), 336.10(7), 336.10(9), and 336.10(10)
d.
used where exposed to direct rays of the sun, unless identified as sunlight resistant
Chapter 7 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 7 - Is it permissible to install a recessed luminaire...Ch. 7 - If a recessed luminaire without an integral...Ch. 7 - Thermal insulation is not permitted to be...Ch. 7 - Recessed luminaires are available for installation...Ch. 7 - Unless specifically designed, all recessed...Ch. 7 - Plans require the installation of surface-mounted...Ch. 7 - A recessed luminaire bears no marking indicating...Ch. 7 - Prob. 8RCh. 7 - Additional backup protection for ballasts can be...Ch. 7 - Prob. 10R
Ch. 7 - The Code places a maximum open-circuit voltage on...Ch. 7 - The letter E in a circle on a ballast nameplate...Ch. 7 - A 120-volt lamp fluorescent ballast for two...Ch. 7 - Can an incandescent lamp dimmer be used to control...Ch. 7 - A good rule-of-thumb to estimate the expected life...Ch. 7 - A post light has a 120-volt, 60-watt lamp...Ch. 7 - Define the following terms. a. A tap conductor is...Ch. 7 - Circle the correct answer for the following...Ch. 7 - Circle the correct answer for the following...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Assuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps, what size box could be installed? Show calculations for both metal and nonmetallic boxes. ___________arrow_forwardThe following problems pertain to luminaires in clothes closets. a. Does the Code permit bare incandescent lamps to be installed in porcelain key-less or porcelain pull-chain lampholders? ________________ b. Does the Code permit bare fluorescent lamp luminaires to be installed? ________________ c. Does the Code permit pendant lampholders to be installed? ________________ d. What is the minimum clearance from the storage area to surface-mounted incandescent luminaires? ________________ e. What is the minimum clearance from the storage area to surface-mounted fluorescent luminaires? ________________ f. What is the minimum distance between recessed incandescent or recessed fluorescent luminaires and the storage area? ________________ g. Define the storage area. ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ h. If a clothes hanging rod is installed where there is access from both sides, such as might be found in a large walk-in clothes closet, define the storage area under that rod. ___________________________________ ___________________________________arrow_forwardThe recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forward
- Refer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwardWhat section of the NEC covers grounding?arrow_forwardQUESTION 9 When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true? a A.This would be approved by code as the gas pipe is only being bonded to the electrical system. b B.This installation would be approved by code, as the gas pipe is not a grounding electrode. c C.Both A and B d D.Neither A nor Barrow_forward
- Where Type MI cable terminates, a seal shall be provided immediately after stripping to prevent the entrance of _____ into the insulation Select one: A. MOISTURE B. NONE OF THE ABOVE C. INSECTS D. ELECTRONSarrow_forwardCircle the correct answer for the following statements: a. Always match a fluorescent lamps wattage and type designation to the type of ballast in the luminaire. (True) (False) b. It really makes no difference what type of fluorescent lamp is used, just so the wattage is the same as marked on the ballast. (True) (False)arrow_forwardelectrical wiring 20th edition residential book chapter 12 review question #27 The following is a layout for the lighting circuit for the Kitchen. Complete the wiring diagram using colored pens or pencils to show the conductors’ insulation color.arrow_forward
- 19. Which of the following is an approved disconnecting means for a feeder or branch circuit supplying a separate building or structure? A. Bonding locknutB. PanelboardC. Circuit breakerD. Overcurrent devicearrow_forwardWhat color fluorescent lamps recommended for residential installationarrow_forwardFor residential wiring, not less than one 15-ampere lighting branch circuit should be provided for every ____________ ft2 of floor area. If 20-ampere lighting branch circuits are used, provide one 20-ampere lighting branch circuit for every ____________ ft2 of floor areaarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning