EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 7, Problem 7R
A recessed luminaire bears no marking indicating that it is “Identified for Through-Wiring.” Is it permitted to run branch-circuit conductors other than the conductors that supply the luminaire through the integral junction box on the luminaire? ___________________
____________________________________________________________________________
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
5. If a separate, wire-type equipment grounding conductor (EGC) is used for any reason, the EGC of a grounding-type receptacle must be connected to which of the following?A. The grounding terminal bar outside the service equipment enclosure in a grounded systemB. An EGC that's part of another branch circuit that originates from where the branch circuit for the receptacle originatesC. Any accessible point on the grounding electrode conductorD. The service conductor outside the service equipment enclosure in an ungrounded system
Where a building or structure is suplkied by more than one service, or a combination of branch circuits, feeders, and services, a permanent plaque or directory must be installed at each sertvice disconnect location denoting all other suplying that building or structure and the area served by each.
A. Services B. Feeders
C. Branch circuits D. All of the above
In order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector?
Explain.
Chapter 7 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 7 - Is it permissible to install a recessed luminaire...Ch. 7 - If a recessed luminaire without an integral...Ch. 7 - Thermal insulation is not permitted to be...Ch. 7 - Recessed luminaires are available for installation...Ch. 7 - Unless specifically designed, all recessed...Ch. 7 - Plans require the installation of surface-mounted...Ch. 7 - A recessed luminaire bears no marking indicating...Ch. 7 - Prob. 8RCh. 7 - Additional backup protection for ballasts can be...Ch. 7 - Prob. 10R
Ch. 7 - The Code places a maximum open-circuit voltage on...Ch. 7 - The letter E in a circle on a ballast nameplate...Ch. 7 - A 120-volt lamp fluorescent ballast for two...Ch. 7 - Can an incandescent lamp dimmer be used to control...Ch. 7 - A good rule-of-thumb to estimate the expected life...Ch. 7 - A post light has a 120-volt, 60-watt lamp...Ch. 7 - Define the following terms. a. A tap conductor is...Ch. 7 - Circle the correct answer for the following...Ch. 7 - Circle the correct answer for the following...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
What is the color code for a 365- five-band precision resistor with a tolerance of 5 percent?
ELECTRICITY FOR TRADES (LOOSELEAF)
Assume a telephone signal travels through a cable at two-thirds the speed of light. How long does it take the s...
Electric Circuits (10th Edition)
When travelers from the USA and Canada visit Europe, they encounter a different power distribution system. Wall...
Electric machinery fundamentals
Write the nodal equations for the network of Fig. 8.137 using the general approach. Find the nodal voltages usi...
Introductory Circuit Analysis (13th Edition)
The voltage source of the circuit shown in Fig. P1.29 is given by s(t)=25cos(4104t45)(V). Obtain an expression ...
Fundamentals of Applied Electromagnetics (7th Edition)
Electric power systems provide energy in a variety of commercial and industrial settings. Make a list of system...
Principles and Applications of Electrical Engineering
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- a. The service head must be located (above) (below) the point where the service-drop conductors are spliced to the service-entrance conductors. (Circle the correct answer.) b. What Code section provides the answer to part (a)? ___________________arrow_forwarda. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardIn order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector red tagged (turned down) the installation. Who is rightthe homeowner or the electrical inspector? Explain. ___________________ ___________________ ___________________arrow_forward
- When a metal junction box is installed as part of the cable wiring to a clothes dryer or electric range, may this box be grounded to the circuit neutral conductor?arrow_forward19. Which of the following is an approved disconnecting means for a feeder or branch circuit supplying a separate building or structure? A. Bonding locknutB. PanelboardC. Circuit breakerD. Overcurrent devicearrow_forwardHow many circuit wires enter the entry ceiling box? How many equipment grounding conductors enter the entry ceiling box?arrow_forward
- If you use 600-volt rated conductors for Class 2 wiring, does the Code permit pulling these conductors through the same raceway as the power conductors? (Yes) (No) (Circle the correct answer.) Give the NEC section number. ____________arrow_forwardRefer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwardIn the conduit layout shown in picture attached, determine how many wires are contained in each conduit between each piece of equipment. Identify each wire with a proper terminal marking, as shown in the example, above the disconnect switch.arrow_forward
- QUESTION 25 Type TC cable shall not be _____. a. installed where it will be exposed to physical damage b. all of these c. installed outside of a race-way or cable tray system, unless permitted in 336.10(4), 336.10(7), 336.10(9), and 336.10(10) d. used where exposed to direct rays of the sun, unless identified as sunlight resistantarrow_forwardWhich of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.arrow_forwardWhen a three-conductor multi-wire circuit is used in place of two separate branch circuits to supply split-wired receptacles, the grounded (neutral) conductor is required to be ____. A. durably markedB. pigtailed so that its continuity does not depend on the presence of a wiring deviceC. connected to the white or silver-colored receptacle binding screwD. both b and carrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License