Chapter 7, Problem 7.4.4P
To determine
(a)
The number of bolts using Load and Resistance Factor Design (LRFD).
To determine
(b)
The number of bolts using Allowable Strength Design (ASD).
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Trending nowThis is a popular solution!
![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
The splice plates shown in Figure 2 are 1/2-inch-thick.
How many 7/8-inch-diameter, Group B bolts are required? The given load consists of 30% dead
load and 70% live load. A36 steel is used. Threads are not excluded from the shear plane.
90 k
Figure 2
a. Use LRFD.
b. Use ASD.
% in.
90 k
A double-angle shape is shown in the figure. The steel is
A36, and the holes are for 2-inch-diameter bolts.
Assume that A₂ = 0.75An.
Ae
1
2
Determine the design tensile strength for LRFD.
Determine the allowable strength for ASD.
CIVIL ENGINEERING
- STEEL DESIGN
AL
Section
2L5 x 3 x 516 LLBB
The splice plates shown in Figure 2 are 1/2-inch-thick.
How many 7/8-inch-diameter, Group B bolts are required? The given load consists of 30% dead
load and 70% live load. A36 steel is used. Threads are not excluded from the shear plane.
90 k
Figure 2
¾ in.
90 k
Chapter 7 Solutions
Bundle: Steel Design, Loose-leaf Version, 6th + Mindtap Engineering, 1 Term (6 Months) Printed Access Card
Ch. 7 - Prob. 7.3.1PCh. 7 - Prob. 7.3.2PCh. 7 - Prob. 7.4.1PCh. 7 - Prob. 7.4.2PCh. 7 - Prob. 7.4.3PCh. 7 - Prob. 7.4.4PCh. 7 - Prob. 7.4.5PCh. 7 - Prob. 7.4.6PCh. 7 - Prob. 7.6.1PCh. 7 - Prob. 7.6.2P
Ch. 7 - Prob. 7.6.3PCh. 7 - Prob. 7.6.4PCh. 7 - Prob. 7.6.5PCh. 7 - Prob. 7.6.6PCh. 7 - Prob. 7.7.1PCh. 7 - Prob. 7.7.2PCh. 7 - Prob. 7.7.3PCh. 7 - Prob. 7.8.1PCh. 7 - Determine the adequacy of the hanger connection in...Ch. 7 - Prob. 7.9.1PCh. 7 - Prob. 7.9.2PCh. 7 - Prob. 7.9.3PCh. 7 - Prob. 7.9.4PCh. 7 - Prob. 7.9.5PCh. 7 - Prob. 7.11.1PCh. 7 - Prob. 7.11.2PCh. 7 - Prob. 7.11.3PCh. 7 - Prob. 7.11.4PCh. 7 - Prob. 7.11.5PCh. 7 - Prob. 7.11.6PCh. 7 - Prob. 7.11.7PCh. 7 - Prob. 7.11.8PCh. 7 - Prob. 7.11.9PCh. 7 - Prob. 7.11.10P
Knowledge Booster
Similar questions
- For the tension member shown, compute the following. a) The tensile design strength. b) The allowable tensile strength. PL x8 A36 steel -12" -Weld FIGURE P3.3-2 |arrow_forward4. Determine the design strength of the connection shown in the Figure below. Thebolts are 25 mm diameter A490 bolts with the threads not in the plane of shear.A36 steel is used (Fy = 250 MPa, Fu = 400 MPa).a. Compute the shear strength for all bolts.b. Compute the bearing strength for the tension member on all bolts.c. Compute the bearing strength for the gusset plate on all bolts.d. Compute the tensile strength of the tension member.e. Compute the design strength of the connection.arrow_forward1.A tension member is 25 mm thick plate as shown. The bolts are 20 mm. diameter high-strength bolts. The steel is A36. Compute the following: 130 mm 25 mm 0 0 a) The design strength for LFRD. b) The allowable strength for ASD. 25 mm CIVIL ENGINEERING STEEL DESIGNarrow_forward
- Considering the following steel connection. The plates in Pink are 9mm steel plates. The middle plate (Yellow) is 18mm thick. The width of the plate is 100mm. The maximum allowable tension stresses on any of the plates is 100Mpa in Gross Area Yielding and 150 Mpa for Net Area or Tension Rupture. The bolts used are 8mm in diameter, the holes are 10mm in diameter, no need to add 1.6mm. The bolts allow a maximum of 280 Mpa of shear. Determine the maximum allowable "P" of the connection in kN.arrow_forwardDesign the size and length of Fillet weld for the lap joint shown below, Use SMAW E70XX process, plates are A-36 steel? 90k LL 40k DL R-X7 5" Gusset P 8 90k LL 40k DLarrow_forwardProblem # 6.0 For the tension member shown, compute the tensile design strength. Weld -6" PL 4X6 A36 steelarrow_forward
- The tension member is a PL 1⁄2 × 6. It is connected to a 3⁄8-inch-thick gusset plate with 7⁄8-inch-diameter bolts. Both components are of A242 steel. Note: A242 Fu = 70ksi dh = db + 1/16’’ Use: Consider deformation at the bolt hole what is the: minimum spacing as per AISC code provisions maximum spacing as per AISC code provisions minimum edge distance as per AISC code provisions maximum edge distance as per AISC code provisionsarrow_forwardA C8 × 11.5 is connected to a gusset plale with 22 mm diameter bolts as shown. The steel is A572 Grade 50. If the member is subjected to dead load and live load only, what is the total scrvice load capacity if the live-to-dead load ratio is 3? Assume that Ae = 0.85Ap. a. Use LRFD. b. Use ASD. Properties of A572 Grade 50: Fy = 345 MPa C8 × 11.5 Fu = 448 MPa Properties of C8 x 11.5: Ag = 2,181 mm? br = 57.4 mm d= 203.2 mm Lw = 5.6 mm lf = 9.9 mmarrow_forwardThe tension member shown in the figure below is a ¹/2 x 10 plate of A36 steel: Fy = 36 ksi, Fu = 58 ksi. The connection is with 9/8-inch-diameter bolts. -→| 20 |einetein | 21 | 6 spaces @2" t = 1/2 in. Compute the nominal strength based on the net section. (Express your answer to three significant figures.) P₁ = kipsarrow_forward
- The tension member is a PL 12 x 6. It is connected to a 38-inch-thick gusset plate with 7/8-inch-diameter bolts. Both components are of A242 steel. Note: A242 Fu = 70ksi dh = db + 1/16" Use: Consider deformation at the bolt hole 3" PL ... PL ½x 6 12" 24" 24" 12" a. What is the minimum spacing as per AISC code provisions Round your answer to 3 decimal places.arrow_forwardThe butt connection shows 8-22 mm diameter bolts spaced as shown below. P- 50 100 50 50 100 50 16 mm +HHHH 40 80 40 12 mm Steel strength and stresses are: Yield strength, Fy = 248 MPa Ultimate strength, Fu = 400 MPa Allowable tensile stress on the gross area = 148 MPa Allowable tensile stress on the net area = 200 MPa Allowable shear stress on the net area = 120 MPa Allowable bolt shear stress, Fv = 120 MPa Based on the gross area of the plate. Based on the net area of the plate. Based on block shear strength. Bolt hole diameter = 25 mm Calculate the allowable tensile load, P, under the following conditions:arrow_forwardA Channel C6x13 is used as a tension member. The holes are for 5/8 inch in diameter of bolts. Using A36 steel with Fy=36 ksi and Fu=58 ksi. The gross area of C6x13 is 3.81 in? and Assume U =0.85 Using LRFD what is the design strength based on Tensile Rupture/Fracture 4 @ 2" a 1 1/2 Ob 3" Oc 1 1/2 " I d e C6 x 13 Round your answer to 3 decimal places.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781337094740/9781337094740_smallCoverImage.gif)
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning