![Bundle: Steel Design, Loose-leaf Version, 6th + Mindtap Engineering, 1 Term (6 Months) Printed Access Card](https://www.bartleby.com/isbn_cover_images/9781337761505/9781337761505_largeCoverImage.gif)
Bundle: Steel Design, Loose-leaf Version, 6th + Mindtap Engineering, 1 Term (6 Months) Printed Access Card
6th Edition
ISBN: 9781337761505
Author: William T. Segui
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 7, Problem 7.6.3P
To determine
(a)
The total number of A307 bolts.
To determine
(b)
The total number of group A bolts.
To determine
(c)
The total number of group B bolts.
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Trending nowThis is a popular solution!
![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
A tension connection consists of A36 steel double angles (two L4x4x1/4 shapes, or 2L4x4x1/4)
fastened to a 4x10 No. 2 Red Oak member with a single row of four 0.875 inch A307 bolts.
The connection is subjected to normal temperatures but wet in-service conditions. Assume
the group action factor is C,=0.95 and the geometry factor is Ca=1. The controlling ASD
load combination is D+ L where L is from occupancy.
Elevation
Cross Section
L4x4x1/4
L4x4x1/4
Pa
Р.
2L4x4x1/4
4х10
4x10
Plan
L4x4x1/4
Pa/2
Pa
4x10
L4x4x1/4
Pa/2
• Determine the load, Pa, that the connection can support based on tension strength of
the 4x10.
Pa=.
lb
• Determine the load, Pa, that the connection can support based on gross tension yield
of the double angles. The ASD design strength for gross tension yield is F,A,/1.67
where F=36 ksi, A,=1.93 in² for each L4x4x1/4.
Pa=.
lb
Problem 5: The lap connection shown consists of a PL1/2"X3" plate connected to a ½ in gusset plate with
¼" longitudinal fillet welds as indicated. The plates are A36 steel and the electrodes are E70XX. Calculate
the length L (in) of the connection to develop the full capacity of the plate. Hint: The full capacity of the
plate will depend on the governing strength of the tension member. Neglect block shear. Use ASD
6" x 1/2"
P
[
T
L
1/4
1/4
E70
- 13²x
P
3" x 1/2"
Determine the maximum service load that can be applied if the live load-to-dead load
ratio is 3.0. Investigate all limit states. The tension member is of A572 Grade 50 steel
and the gusset plate is A36. The weld is a 1/8-inch fillet weld with E70 electrodes.
a. Use LRFD.
b. Use ASD.
13".
MC8x8.5-
1-3/8"-
Chapter 7 Solutions
Bundle: Steel Design, Loose-leaf Version, 6th + Mindtap Engineering, 1 Term (6 Months) Printed Access Card
Ch. 7 - Prob. 7.3.1PCh. 7 - Prob. 7.3.2PCh. 7 - Prob. 7.4.1PCh. 7 - Prob. 7.4.2PCh. 7 - Prob. 7.4.3PCh. 7 - Prob. 7.4.4PCh. 7 - Prob. 7.4.5PCh. 7 - Prob. 7.4.6PCh. 7 - Prob. 7.6.1PCh. 7 - Prob. 7.6.2P
Ch. 7 - Prob. 7.6.3PCh. 7 - Prob. 7.6.4PCh. 7 - Prob. 7.6.5PCh. 7 - Prob. 7.6.6PCh. 7 - Prob. 7.7.1PCh. 7 - Prob. 7.7.2PCh. 7 - Prob. 7.7.3PCh. 7 - Prob. 7.8.1PCh. 7 - Determine the adequacy of the hanger connection in...Ch. 7 - Prob. 7.9.1PCh. 7 - Prob. 7.9.2PCh. 7 - Prob. 7.9.3PCh. 7 - Prob. 7.9.4PCh. 7 - Prob. 7.9.5PCh. 7 - Prob. 7.11.1PCh. 7 - Prob. 7.11.2PCh. 7 - Prob. 7.11.3PCh. 7 - Prob. 7.11.4PCh. 7 - Prob. 7.11.5PCh. 7 - Prob. 7.11.6PCh. 7 - Prob. 7.11.7PCh. 7 - Prob. 7.11.8PCh. 7 - Prob. 7.11.9PCh. 7 - Prob. 7.11.10P
Knowledge Booster
Similar questions
- Select an American Standard Channel shape for the following tensile loads: dead load = 54 kips, live load = 80 kips, and wind load = 75 kips. The connection will be with longitudinal welds. Use an estimated shear lag factor of U = 0.85. (In a practical design, once the member was selected and the connection designed, the value of U would be computed and the member design could be revised if necessary.) The length is 17.5 ft. Use Fy=50 ksi and Fu=65 ksi. a. Use LRFD. b. Use ASD.arrow_forwardDetermine the adequacy of the hanger connection in Figure P7.8-2 Account for prying action. a. Use LRFD. b. Use ASD.arrow_forwardProblem. A bolted connection shown consists of two plates 300 mm x 12 mm connected by 4 - 22 mm diameter bolts. 12 mm bolts t=12 mm t=12 mm P. P- P 300 75 75 75 Edge distances -75 mm dhole for tensile and rupture d, +3 mm dnole for bearing strength for L- de +1.5 mm Fy 248 MPa F.- 400 MPaarrow_forward
- Determine the maximum service load P (ASD) that the connection can resist. Use 27 mm Ø A490-N bolts, and 10 mm A-36 plate and a load P with a slope 1H: 2V. Assume that edge distance and bolt spacing are not critical. ***Note: Lod P is acting at a slope of 1H: 2Varrow_forwardDetermine the maximum service load P that can be resisted safely by the welded connection shown. Use ASD. E80 10 150 300 200arrow_forwardThe billboard post support a 5KN dead load as shown. The cantilever beam and the brace is pinnedconnected to the post. Assume that the connections along the cap and the cap plate is adequate, as well asthe gusset plate and the cap plate. Use LRFD design considerations.a.) Determine the ultimate tensile force the brace carries. b.) Determine the adequacy of Connection 1 the bolt where 2- 16mm Ø A325 hex bolt and the plateswhere A36 steel. c.) If the connection at Connection 1 will be a welded connection what will be the adequate thickness ofthe weld. Note that the welds are only applied at the sides of the cap plate. Use electrode 70 for theweld. d.) Determine the adequacy of the connection due to shear and tension in Connection 2 if the bolts were4- 12mm Ø A325 hex bolt.arrow_forward
- Determine the maximum service load P that can be resisted safely by the welded connection shown. Use ASD. E80 10 150 300 K. 200arrow_forwardIf the 18 mm plate is connected to two cover plate of 10 mm on top and bottom, what is the capacity of the connection in double shear? Assume that the shear planes pass though the threaded portion. State the condition necessary for these strengths to be available. (Draw the connect first and calculate the capacity)arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781337094740/9781337094740_smallCoverImage.gif)
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning