The total work required to fill the tank.
The total heat transferred from the air in the tank.
Answer to Problem 199RP
The total work required to fill the tank is
The total heat transferred from the air in the tank is
Explanation of Solution
Refer to Table A-2Ea, obtain the properties of air at room temperature.
Calculate the initial mass of air in the tank.
Here, pressure and temperature at initial state is
Calculate the final mass of air in the tank.
Here, pressure and temperature at final state is
Since the compressor operates as an isentropic device, express the temperature at state 2.
Here, specific heat ratio is k.
Express the conservation of mass applied to the tank.
Here, change of mass is
Write the equation of total power required to fill the tank using first law.
Here, specific enthalpy at state 2 is
Merge the ideal gas equation of state and constant specific heats in Equation (III).
Use the temperature relation across the compressor and multiply by dt in Equation (IV).
Here, change in pressure is dP.
Integrate Equation (V) for initial and final states.
Here, pressures at initial and final states are
Apply the first law to the tank and compressor.
Here, specific enthalpy at initial state is
Integrate Equation (VII) to calculate the total heat transferred from the air in the tank.
Here, specific internal energy at initial and final state is
Conclusion:
Substitute 1 atm for
Substitute 10 atm for
Substitute
Thus, the total work required to fill the tank is
Substitute
Thus, the total heat transferred from the air in the tank is
Want to see more full solutions like this?
Chapter 7 Solutions
CONNECT FOR THERMODYNAMICS: AN ENGINEERI
- It is possible to generate 3MW of power with a turbine through which 20 kg/s of steam pass under the following conditions: inlet and outlet velocities: 200 m/s and 50 m/s. Input and output enthalpies: 3000 kJ/kg and 2900 kJ/kg.arrow_forwardA pump at a power plant supplies water to the boiler at a flow rate of 1,000 gal/min, measured at the pump inlet. Water enters the pump at 185 psig and 300 F. The pump discharge pressure is 2,985 psig. The isentropic efficiency of the pump is 70%. What is the required pump input power in HP? (Assume atmospheric pressure is 15 psia.) Answers: 2300 HP 1500 HP 1200 HP 2500 HP 1700 HP 2000 HParrow_forwardn a power plant, the steam from the boiler reaches the turbine at a temperature of 700 °C. The spent steam leaves the turbine at 100 °C. Calculate the maximum efficiency of the turbine and compare it to the typical value.arrow_forward
- A motor-pump system with 90% efficiency is designed to increase the pressure of was from 101kPa to 250 kPa while water is flowing at a rate of 2 m^3/s. Assuming no change in the kinetic and potential energy of water, what is the expected electric power usage of the system?arrow_forwardA turbine is supplied with 22,500 lb./hr of steam at 166 psia and 480°F with an initial speed of 6000 fpm at an elevation of 5 ft. above the exhaust outlet. Radiation and frictional losses are 140,000 Btu/hr. At the entrance h1 = 1261.8 Btu/lb. At the exit, p2 = 3 in. Hg abs., v2 = 24,000 fpm, and h2= 1000.5 Btu/lb. Compute the work in horsepower.arrow_forwardWater with a specific volume of 0.001 m3×kg-1 flows through a centrifugal pump that operates under steady flow conditions at a volumetric flow rate of 3.0 m3×min-1 from an initial pressure of 75 kPa to a final pressure of 220 kPa. The diameter of the suction inlet to the pump is 12 cm and the diameter of the discharge outlet is 8 cm. If the suction and discharge outlets are at the same level and no change in internal energy, determine the work (HP) done on the water by the pump.arrow_forward
- A pump at a power plant supplies water to the boiler at a flow rate of 1,000 gal/min, measured at the pump inlet. Water enters the pump at 185 psig and 300 F. The pump discharge pressure is 2,985 psig. The isentropic efficiency of the pump is 70%. What is the required pump input power in HP? (Assume atmospheric pressure is 15 psia.) 1500 HP 2500 HP 2000 HP 2300 HP 1700 HP 1200 HParrow_forwardMethane is compressed in a two-stage, double-acting compressor which is electrically driven at 165 rpm. The low pressure cylinder (30.5 times 35.5 cm) receives 6.86 cu m per minute of air at 96.53 kPa, 43.3 degree C, and the high pressure cylinder (20.3 times 35.5 cm) discharges the methane at 717.06 kPa. The isothermal overall efficiency is 74%. Find n_v and the kW output of the motor.arrow_forwardMethane is compressed in a two-stage, double-acting compressor which is electrically driven at 165 rpm. The low pressure cylinder (30.5 times 35.5 cm) receives 6.86 cu m per minute of air at 96.53 kPa, 43.3 degree C, and the high pressure cylinder (20.3 times 35.5 cm) discharges the methane at 717.06 kPa. The isothermal overall efficiency is 74%. Find n_v and the kW output of the motor.arrow_forward
- A site is being considered for wind power generation. At this site, the wind blows steadily at 9 m/s for 2,579 hours per year. Assuming the wind velocity is negligible at other times for simplicity, determine the kWh/year that can be produced at the site for a turbine with a mechanical efficiency of 100% and an effective flow area of 5 m2. Use a value of 1.25 kg/m3 for the density of the air. Give your answer in killowatt-hours per year (kWh/year). Hint: I reccomend starting by finding the kinetic energy (kJ/kg) of the wind. Hint 2: Multiply the power generation (kW) by the number of hours of wind per year (h/year) to get kWh/year.arrow_forwardWe want to pump subsoil water at a rate of 6 L / s by means of a submerged pump, with 90% overall efficiency, to a pond whose free surface is 25 meters above the surface in the lake. The water inlet to the pump is 1 m below the surface in the lake, where the pressure is 1.1 atm. Neglect variations in kinetic energy and determine:Data: 1 atm = 101.325 kPa PATM = 1 atm Water density = 1000 kg / m3 a) The electrical power consumed by the pump, in kW b) What is the daily electricity consumption (in kWh) if the 30 m3 capacity tank is filled 2 times a day?arrow_forwardA mini hydro power station takes in 3 cubic meters per second of water from a wide open reservoir through its turbine from an elevation of 15 meters and discharges to its surroundings at 0.50 m/s. During data gathering, the rotational force of the turbine shaft is measured 250 N for a distance of 2 m from its center axis at 2,850 rpm. If the electrical generator is 88% efficient, determine the turbine efficiency and the electrieity output of this station. Show the energy or schematie diagram and label it accordingly.arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY