Loose Leaf for Fundamentals of Electric Circuits Format: LooseLeaf
6th Edition
ISBN: 9781259657054
Author: Alexander
Publisher: Mcgraw Hill Publishers
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
thumb_up100%
Chapter 12, Problem 2P
What is the phase sequence of a balanced three-phase circuit for which
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A three-phase circuit has two parallel balanced delta loads, one of the 18 Ω resistors and one of 12 Ω resistors. The magnitude of the total line current, when the line-to-line voltage is 380 Vrms , is
Select one:
a.
208 Arms
b.
91 Arms
c.
120 Arms
d.
360 Arms
n a balanced 3-phase source, the three phase voltages are equal in phase.
Select one:
True
False
A 230-V balanced three-phase source delivers the following load currents: Iab = 12 cis 0°; Ibc = 12 cis (-60°) and Ica = 16 cis 60°. Determine the readings of the two wattmeters properly connected with line b as the common potential terminal Show phasor
Chapter 12 Solutions
Loose Leaf for Fundamentals of Electric Circuits Format: LooseLeaf
Ch. 12.2 - Given that Vbn=22030V, find Van and Vcn, assuming...Ch. 12.3 - A Y-connected balanced three-phase generator with...Ch. 12.4 - One line voltage of a balanced Y-connected source...Ch. 12.5 - A positive-sequence, balanced -connected source...Ch. 12.6 - In a balanced -Y circuit, Vab=44015 and ZY = (12 +...Ch. 12.7 - For the Y-Y circuit in Practice Prob. 12.2,...Ch. 12.7 - Calculate the line current required for a 30-kW...Ch. 12.7 - Assume that the two balanced loads in Fig....Ch. 12.8 - The unbalanced -load of Fig. 12.24 is supplied by...Ch. 12.8 - Find the line currents in the unbalanced...
Ch. 12.9 - Prob. 11PPCh. 12.9 - For the unbalanced circuit in Fig. 12.32, use...Ch. 12.10 - Repeat Example 12.13 for the network in Fig. 12.24...Ch. 12.10 - Let the line voltage VL = 208 V and the wattmeter...Ch. 12.10 - If the load in Fig. 12.35 is delta-connected with...Ch. 12 - What is the phase sequence of a three-phase motor...Ch. 12 - If in an acb phase sequence, , then Vcn is:Ch. 12 - Which of these is not a required condition for a...Ch. 12 - Prob. 4RQCh. 12 - Prob. 5RQCh. 12 - In a Y-Y system, a line voltage of 220 V produces...Ch. 12 - In a - system, a phase voltage of 100 V produces a...Ch. 12 - When a Y-connected load is supplied by voltages in...Ch. 12 - Prob. 9RQCh. 12 - Prob. 10RQCh. 12 - If Vab = 400 V in a balanced Y-connected...Ch. 12 - What is the phase sequence of a balanced...Ch. 12 - Given a balanced Y-connected three-phase generator...Ch. 12 - A three-phase system with abc sequence and VL =...Ch. 12 - For a Y-connected load, the time-domain...Ch. 12 - Using Fig. 12.41, design a problem to help other...Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - In a balanced three-phase Y-Y system, the source...Ch. 12 - A balanced Y-Y four-wire system has phase voltages...Ch. 12 - For the circuit in Fig. 12.43, determine the...Ch. 12 - In the Y- system shown in Fig. 12.44, the source...Ch. 12 - Using Fig. 12.45, design a problem to help other...Ch. 12 - In the balanced three-phase Y- system in Fig....Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - The circuit in Fig. 12.48 is excited by a balanced...Ch. 12 - A balanced delta-connected load has a phase...Ch. 12 - A positive sequence wye-connected source where ,...Ch. 12 - If Van = 22060 V in the network of Fig. 12.49,...Ch. 12 - For the - circuit of Fig. 12.50, calculate the...Ch. 12 - Prob. 20PCh. 12 - Three 440-V generators form a delta-connected...Ch. 12 - Find the line currents IaA, IbB, and IcC in the...Ch. 12 - A balanced delta connected source is connected to...Ch. 12 - A balanced delta-connected source has phase...Ch. 12 - In the circuit of Fig. 12.54, if , , , find the...Ch. 12 - Using Fig. 12.55, design a problem to help other...Ch. 12 - A -connected source supplies power to a...Ch. 12 - The line-to-line voltages in a Y-load have a...Ch. 12 - A balanced three-phase Y- system has V rms and Z =...Ch. 12 - In Fig. 12.56, the rms value of the line voltage...Ch. 12 - A balanced delta-connected load is supplied by a...Ch. 12 - Design a problem to help other students better...Ch. 12 - A three-phase source delivers 4.8 kVA to a...Ch. 12 - A balanced wye-connected load with a phase...Ch. 12 - Three equal impedances, 60 + j30 each, are...Ch. 12 - A 4200-V, three-phase transmission line has an...Ch. 12 - The total power measured in a three-phase system...Ch. 12 - Given the circuit in Fig. 12.57 below, find the...Ch. 12 - Find the real power absorbed by the load in Fig....Ch. 12 - For the three-phase circuit in Fig. 12.59, find...Ch. 12 - A balanced delta-connected load draws 5 kW at a...Ch. 12 - A balanced three-phase generator delivers 7.2 kW...Ch. 12 - Refer to Fig. 12.48. Obtain the complex power...Ch. 12 - A three-phase line has an impedance of 1 + j3 per...Ch. 12 - A balanced wye-connected load is connected to the...Ch. 12 - A three-phase load consists of three 100-...Ch. 12 - The following three parallel-connected three-phase...Ch. 12 - A balanced, positive-sequence wye-connected source...Ch. 12 - Each phase load consists of a 20- resistor and a...Ch. 12 - A balanced three-phase source with VL = 240 V rms...Ch. 12 - Consider the wye-delta system shown in Fig. 12.60....Ch. 12 - A four-wire wye-wye circuit has...Ch. 12 - Using Fig. 12.61, design a problem that will help...Ch. 12 - A balanced three-phase Y-source with VP = 880 V...Ch. 12 - A three-phase supply, with the line-to-line...Ch. 12 - Using Fig. 12.63, design a problem to help other...Ch. 12 - Determine the line currents for the three-phase...Ch. 12 - Solve Prob. 12.10 using PSpice or MultiSim. For...Ch. 12 - The source in Fig. 12.65 is balanced and exhibits...Ch. 12 - Use PSpice or MultiSim to determine Io in the...Ch. 12 - Given the circuit in Fig. 12.67, use PSpice or...Ch. 12 - Using Fig. 12.68, design a problem to help other...Ch. 12 - Use PSpice or MultiSim to find currents IaA and...Ch. 12 - For the circuit in Fig. 12.58, use PSpice or...Ch. 12 - A balanced three-phase circuit is shown in Fig....Ch. 12 - A three-phase, four-wire system operating with a...Ch. 12 - As shown in Fig. 12.72, a three-phase four-wire...Ch. 12 - Meter readings for a three-phase wye-connected...Ch. 12 - A certain store contains three balanced...Ch. 12 - The two-wattmeter method gives P1=1200W and...Ch. 12 - In Fig. 12.73, two wattmeters are properly...Ch. 12 - If wattmeters W1 and W2 are properly connected...Ch. 12 - For the circuit displayed in Fig. 12.74, find the...Ch. 12 - Predict the wattmeter readings for the circuit in...Ch. 12 - Prob. 75PCh. 12 - Show that the I2R losses will be higher for a...Ch. 12 - A three-phase generator supplied 10 kVA at a power...Ch. 12 - Prob. 78CPCh. 12 - A balanced three-phase generator has an abc phase...Ch. 12 - A balanced three-phase source furnishes power to...Ch. 12 - A professional center is supplied by a balanced...Ch. 12 - A balanced three-phase system has a distribution...Ch. 12 - A commercially available three-phase inductive...Ch. 12 - Figure 12.76 displays a three-phase...Ch. 12 - Design a three-phase heater with suitable...Ch. 12 - For the single-phase three-wire system in Fig....Ch. 12 - Consider the single-phase three-wire system shown...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A balanced star-connected source has phase voltage Vab = 416 ∠30o V and a positive phase sequence. If this is connected to a balanced delta-connected load, find the line and phase currents. Take the load impedance per phase as 45 ∠45o Ω and line impedance per phase as 5+j10 Ω.arrow_forwardA balanced star-connected source has phase voltage Vab = 416 ∠30º V and a positive phasesequence. If this is connected to a balanced delta-connected load, find the line and phase currents.Take the load impedance per phase as 35 ∠30º Ω and line impedance per phase as 6+j3 Ω.arrow_forwardA balanced three-phase star-connected R-C load of 145 kW takes a current of 54 A with a line voltage of 900 V, 50 Hz. Find the circuit constants of the load per phase. Impedance, Power factor , Resistancearrow_forward
- A balance three phase Y-connected source has using positive phase sequence,Van = 390/30° V. Determine the Vac. please cllear writing, thanksarrow_forward1. Three impedances Z1, Z2 and Z3 are delta-connected to a symmetrical 3-phase, 400 V supply of phase sequence RYB. Z1 = (8 – j 6) Ω and is connected between lines R and Y. Z2 = (6 + j 8) Ω and is connected between lines Y and B. Z3 = (10 + j 0) Ω and is connected between lines B and R. Calculate (i) line and phase currents (ii) power per phase (iii) total power. Verify the results by creating a MATLAB Simulink model and program. Obtain the plots for the currents and voltages. Repeat for a case when the same loads are now connected in star.arrow_forwardA three-phase load has a line voltage of 480V and a line current of 10A. What is the three phase apparent power of the load? Possible answers 8.3kVA 4.8kVA 14.4kVA 9600VAarrow_forward
- Given a balanced Y-Y four wire system Load impedance per phase = 19 +j13 ohms Line impedance per phase = 1 + j2 ohms Van = 120∠0; Vbn = 120 ∠ -120; Vcn = 120∠120 Solve for Ia, Ib, Ic, Inarrow_forwardThe equivalent impedance per phase of a star-connected load are as follows: Za= 100 Ohms, Zb=j5 Ohms, Zc= -j5 Ohms. If the load is connected to a 440 V supply, phase sequence an-bn-cn. Total power of the load." (THIS PROBLEM IS MULTIPLE CHOICE PLEASEE CHOOSE A LETTER BELOW AND PROVIDE YOUR CLEAR SOLUTION!) A 880 VA lag B 645.3333 VA C 717 VA D 880 VA leadarrow_forwardThe line-to-line voltages in an unbalanced three-phase supply are V_ab = 600 36.87 degree, V_bc = 800 126.87 degree, and = 1000 -90 degree. A Y-connected load with a resistance of 37 Ohm per phase is connected to the supply. Determine 1)The symmetrical components of voltage. 2)The phase voltages. 3)The line currents.arrow_forward
- A balanced three-phase star-connected R-C load of 140 kW takes a current of 72A with a line voltage of 1300 V , 50 Hz. Find the circuit constants of the load per phase. Impedance Power factor Resistance Xc carrow_forward4-3. A balanced three-phase Y load has one phase voltage of ??? = 277 ∠ 450 V. If the phase sequence is ACB, find the line voltages VCA, VAB and VBC.arrow_forwardA balanced 3-phase a-b-c system with line-to-line voltage Vab = 20800 V supplies to a balanced connected load of 3 kW with a power factor of 0.8 (lag) through ideal conductors. Find the line currents. Draw the phasor diagram.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License