Concept explainers
For the Y-Y circuit in Practice Prob. 12.2, calculate the complex power at the source and at the load.
A Y-connected balanced three-phase generator with an impedance of 0.4 + j0.3 Ω per phase is connected to a Y-connected balanced load with an impedance of 24 + j19 Ω per phase. The line joining the generator and the load has an impedance of 0.6 + j0.7 Ω per phase. Assuming a positive sequence for the source voltages and that find: (a) the line voltages, (b) the line currents.
Want to see the full answer?
Check out a sample textbook solutionChapter 12 Solutions
Loose Leaf for Fundamentals of Electric Circuits Format: LooseLeaf
Additional Engineering Textbook Solutions
Introductory Circuit Analysis (13th Edition)
Electronics Fundamentals: Circuits, Devices & Applications
Electric Motors and Control Systems
Electric Circuits. (11th Edition)
Microelectronics: Circuit Analysis and Design
Electric machinery fundamentals
- A balanced three-phase Y-connected source with positive sequance has an internal voltage of 120 V/phase. The source feeds a balanced three-phase Y-connected load having an impedance of 39 + j28 Ω /phase. The impedance of the transmission line connecting the source to the load is 1 + j2 Ω /phase. The a-phase of the source is the reference voltage. a) Draw the equivalent per-phase-circuit for the phase "a". b) Calculate the three line currents in the transmission lines. c) Calculate the three phase voltages at load.arrow_forwardA balanced three-phase Y-connected source with positive sequance has an internal voltage of 120 V/phase. The source feeds a balanced three-phase Y-connected load having an impedance of 39 + j28 Ω /phase. The impedance of the transmission line connecting the source to the load is 1 + j2 Ω /phase. The a-phase of the source is the reference voltage. a) Draw the equivalent per-phase-circuit for the phase "a". b) Calculate the three line currents in the transmission lines. c) Calculate the three phase voltages at load. d) Calculate the three line-to-line voltages at the terminals of the load. e) Calculate the total average power in watts delivered to the load. f) Calculate the total complex power in VA delivered by the source.arrow_forward3. A balanced delta connected load of "17+j18 - per phase is connected at the end of a three-phase line. The line impedance is 7+j9 - per phase. The line is supplied from a three-phase source with a line-to-line voltage of 207.85 Vrms. Taking phase "a" voltage Va as reference, determine the following: (a) Current in phase a. (b) Total complex power supplied from the source. (c) Magnitude of the line-to-line voltage at the load terminal.arrow_forward
- A Y-Y three-phase system has a source of 380 V and a load of impedance of 6+j5 Ohm/phase through a transmission line of 2+j 1 Ohm/phase.Plot this Y-Y three-phase system then calculate complex power supplied by the source.arrow_forwardA balanced, positive-sequence, Y-connected voltage source with Eab = 480∠0o volts is applied to abalanced-∆ load with Z∆ = 30 ∠40o Ω. The line impedance between the source and load is ZL = 1 ∠850 Ω.for each phase. Calculate the line currents, the ∆ -load currents, and the voltages at the load terminals.Recall that ZY = Z∆/3arrow_forwardThree-phase Circuits1- Explain in details the relation between phase and line voltages and currents in a star-connected balanced positive sequence three-phase system. Use only one method of analysis.2- A Y-Y three-phase system has a source of 380 V and a load of impedance of 6+j5Ohm/phase through a transmission line of 2+j 1 Ohm/phase. Calculate complex powersupplied by the source.arrow_forward
- 1. A three-phase star source supplies a balanced three-phase load in a delta configuration. Knowing that the phase voltages are Van = 120∠30 ° and Vcn = 120∠-90 °, determine Vbn and indicate the type of sequence in which the three-phase source works. Also, knowing that the three-phase impedance is Z = (2 + j) Ω, determine the line voltage and the line current of each passive element.arrow_forwardA three-phase 6OO-V circuit has two balanced loads connected in parallel, one Δ impedance 9?∠40 ° Ω and the other Y impedance 5? ∠30 ° Ω. Find the total current of the effective line and the total average power absorbed.arrow_forward3. A balanced delta connected load of "14+J18" ohm - per phase is connected at the end of a three-phase line. The line impedance is "7+J12" ohm - per phase. The line is supplied from a three-phase source with a line-to-line voltage of 207.85 Vrms. Taking phase "a" voltage Va as reference, determine the following: (a) Current in phase a. (b) Total complex power supplied from the source. (c) Magnitude of the line-to-line voltage at the load terminal.arrow_forward
- The 3-phase Y-connected load is supplied with power by a balanced 3-phase Y-connected source ABC. The transmission line has a per-phase impedance of 1+j1 ohms. The load impedance is per-phase 8+j3 ohms. If the voltage across phase 'A' of the load is 104.02∠26.6° V rms (Vρ = 104.02 V rms), determine the source phase voltage. Van=120∠30° V rms, Vbn=120∠(-90°) V rms, Vcn=120∠(-210°) V rms,arrow_forwardSuppose you are Mr. Y who is working as an assistant engineer of PGCB. You have studied a wye-wye system during your investigation of a three-phase system. In this system, a Y-connected balanced three-phase generator is connected to a Y- connected balanced load with an impedance of 24 + j19 ohm per phase. The line joining the generator and the load has an impedance of 0.6 + j0.7 ohm per phase. Assuming a positive sequence for the source voltages and that Van = Xarrow_forwardA balanced three-phase Y-source with Vph=221 vrms drives a Y-connected three-phase load with phase impedance Za=84 Ohm, Zb=2+j11 ohm, and Zc=j84 ohm. Calculate the line currents and total complex power delivered to the load. Assume that the neutrals are connected.arrow_forward
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning