a) 436 HZ
Interpretation:
Many nuclei have spin and all nuclei are electrically charged. If an external magnetic field is applied, an energy transfer is possible between the ground energy to a higher energy level.
Concept introduction:
The exact frequency necessary for resonance depends both on the strength of the external magnetic field, the identity of the nucleus, and the electronic environment of the nucleus. If a very strong magnetic field is applied, the energy difference between the two spin states is larger and higher-frequency (higher-energy) radiation is required for a spin-flip. If a weaker magnetic field is applied, less energy is required to effect the transition between nuclear spin states.
b) 956 HZ
Interpretation:
Many nuclei have spin and all nuclei are electrically charged. If an external magnetic field is applied, an energy transfer is possible between the ground energy to a higher energy level.
Concept introduction:
The exact frequency necessary for resonance depends both on the strength of the external magnetic field, the identity of the nucleus, and the electronic environment of the nucleus. If a very strong magnetic field is applied, the energy difference between the two spin states is larger and higher-frequency (higher-energy) radiation is required for a spin-flip. If a weaker magnetic field is applied, less energy is required to effect the transition between nuclear spin states.
c) 1504 HZ
Interpretation:
Many nuclei have spin and all nuclei are electrically charged. If an external magnetic field is applied, an energy transfer is possible between the ground energy to a higher energy level.
Concept introduction:
The exact frequency necessary for resonance depends both on the strength of the external magnetic field, the identity of the nucleus, and the electronic environment of the nucleus. If a very strong magnetic field is applied, the energy difference between the two spin states is larger and higher-frequency (higher-energy) radiation is required for a spin-flip. If a weaker magnetic field is applied, less energy is required to effect the transition between nuclear spin states.
Want to see the full answer?
Check out a sample textbook solutionChapter 13 Solutions
Bundle: Organic Chemistry, Loose-leaf Version, 9th + LMS Integrated for OWLv2, 4 terms (24 months) Printed Access Card
- The following 1H NMR peaks were recorded on a spectrometer operating at 200 MHz. Convert each into δ units. (a) CHCl3; 1454 Hz (b) CH3Cl; 610 Hz (c) CH3OH; 693 Hz (d) CH2Cl2; 1060 Hzarrow_forwardThe 1H NMR spectrum of methylbenzene (C6H5CH3) recorded on a 500 Mhz spectrometer consists of signals at chemical shifts of 2.21 parts per million and 7.10 ppm. calculate the frequency, downfield of TMS, of each absorption.arrow_forwardA signal is seen at 600 Hz from the TMS signal in an NMR spectrometer with a 300-MHz operating frequency. a. What is the chemical shift of the signal? b. What is its chemical shift in an instrument operating at 500 MHz? c. How many hertz from the TMS signal is the signal in a 500-MHz spectrometer?arrow_forward
- Describe the 1H-NMR spectrum of 4-bromoaniline (chemical shift, integration, multiple). Make a table and describe the results.arrow_forwardHow many signals are possible in the 13C NMR Spectrum of 1-butene? Please provide the structure and signals relevant to the atomsarrow_forwardWhy does peak-splitting occur in NMR spectrum?arrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningOrganic ChemistryChemistryISBN:9781305580350Author:William H. Brown, Brent L. Iverson, Eric Anslyn, Christopher S. FootePublisher:Cengage Learning
- Physical ChemistryChemistryISBN:9781133958437Author:Ball, David W. (david Warren), BAER, TomasPublisher:Wadsworth Cengage Learning,Organic Chemistry: A Guided InquiryChemistryISBN:9780618974122Author:Andrei StraumanisPublisher:Cengage Learning