Question
Chapter 2, Problem 2.41P
To determine
The power triangle.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A three-phase, wye connected alternator is rated at 720 kVA, 2400 V, 60 Hz. At the rated load, determine:
the output, in kilowatts, at 80% lagging power factor.
the full-load line current.
the full-load current rating of each of the three windings.
the voltage across each winding
Two 15-kVA, 400-V, 3-ph alternators in parallel supply a total load of 25 kVA at 0.8p.f. lagging. If one alternator shares half the power at unity p.f., determine thep.f. and kVA shared by the other alternator.
A 5000 kVA, 6600 V , 3 - phase , star connected alternator has a resistance of 0.75 ohm per phase. Estimate by zero power factor method the regulation for a load of 500 A at power factor (a) unity, (b) 0.9 leading and (c) 0.71 lagging, form the open circuit and full load, zero power factor curves:
Field current, A Open circuit voltage, V ZPF curve, V
32 3100 0
50 4900 1850
75 6600 4250
100 7500 5800
140 8300 7000
Chapter 2 Solutions
POWER SYS. ANALYSIS+DESIGN
Ch. 2 - The rms value of v(t)=Vmaxcos(t+) is given by a....Ch. 2 - If the rms phasor of a voltage is given by V=12060...Ch. 2 - If a phasor representation of a current is given...Ch. 2 - Prob. 2.4MCQCh. 2 - Prob. 2.5MCQCh. 2 - Prob. 2.6MCQCh. 2 - Prob. 2.7MCQCh. 2 - Prob. 2.8MCQCh. 2 - Prob. 2.9MCQCh. 2 - The average value of a double-frequency sinusoid,...
Ch. 2 - The power factor for an inductive circuit (R-L...Ch. 2 - The power factor for a capacitive circuit (R-C...Ch. 2 - Prob. 2.13MCQCh. 2 - The instantaneous power absorbed by the load in a...Ch. 2 - Prob. 2.15MCQCh. 2 - With generator conyention, where the current...Ch. 2 - Consider the load convention that is used for the...Ch. 2 - Prob. 2.18MCQCh. 2 - The admittance of the impedance j12 is given by...Ch. 2 - Consider Figure 2.9 of the text, Let the nodal...Ch. 2 - The three-phase source line-to-neutral voltages...Ch. 2 - In a balanced three-phase Y-connected system with...Ch. 2 - In a balanced system, the phasor sum of the...Ch. 2 - Consider a three-phase Y-connected source feeding...Ch. 2 - For a balanced- load supplied by a balanced...Ch. 2 - A balanced -load can be converted to an...Ch. 2 - When working with balanced three-phase circuits,...Ch. 2 - The total instantaneous power delivered by a...Ch. 2 - The total instantaneous power absorbed by a...Ch. 2 - Under balanced operating conditions, consider the...Ch. 2 - One advantage of balanced three-phase systems over...Ch. 2 - While the instantaneous electric power delivered...Ch. 2 - Given the complex numbers A1=630 and A2=4+j5, (a)...Ch. 2 - Convert the following instantaneous currents to...Ch. 2 - The instantaneous voltage across a circuit element...Ch. 2 - For the single-phase circuit shown in Figure...Ch. 2 - A 60Hz, single-phase source with V=27730 volts is...Ch. 2 - (a) Transform v(t)=75cos(377t15) to phasor form....Ch. 2 - Let a 100V sinusoidal source be connected to a...Ch. 2 - Consider the circuit shown in Figure 2.23 in time...Ch. 2 - For the circuit shown in Figure 2.24, compute the...Ch. 2 - For the circuit element of Problem 2.3, calculate...Ch. 2 - Prob. 2.11PCh. 2 - The voltage v(t)=359.3cos(t)volts is applied to a...Ch. 2 - Prob. 2.13PCh. 2 - A single-phase source is applied to a...Ch. 2 - Let a voltage source v(t)=4cos(t+60) be connected...Ch. 2 - A single-phase, 120V(rms),60Hz source supplies...Ch. 2 - Consider a load impedance of Z=jwL connected to a...Ch. 2 - Let a series RLC network be connected to a source...Ch. 2 - Consider a single-phase load with an applied...Ch. 2 - A circuit consists of two impedances, Z1=2030 and...Ch. 2 - An industrial plant consisting primarily of...Ch. 2 - The real power delivered by a source to two...Ch. 2 - A single-phase source has a terminal voltage...Ch. 2 - A source supplies power to the following three...Ch. 2 - Consider the series RLC circuit of Problem 2.7 and...Ch. 2 - A small manufacturing plant is located 2 km down a...Ch. 2 - An industrial load consisting of a bank of...Ch. 2 - Three loads are connected in parallel across a...Ch. 2 - Prob. 2.29PCh. 2 - Figure 2.26 shows three loads connected in...Ch. 2 - Consider two interconnected voltage sources...Ch. 2 - Prob. 2.35PCh. 2 - Prob. 2.36PCh. 2 - Prob. 2.37PCh. 2 - Prob. 2.38PCh. 2 - Prob. 2.39PCh. 2 - A balanced three-phase 240-V source supplies a...Ch. 2 - Prob. 2.41PCh. 2 - A balanced -connected impedance load with (12+j9)...Ch. 2 - A three-phase line, which has an impedance of...Ch. 2 - Two balanced three-phase loads that are connected...Ch. 2 - Two balanced Y-connected loads, one drawing 10 kW...Ch. 2 - Three identical impedances Z=3030 are connected in...Ch. 2 - Two three-phase generators supply a three-phase...Ch. 2 - Prob. 2.48PCh. 2 - Figure 2.33 gives the general -Y transformation....Ch. 2 - Consider the balanced three-phase system shown in...Ch. 2 - A three-phase line with an impedance of...Ch. 2 - A balanced three-phase load is connected to a...Ch. 2 - What is a microgrid?Ch. 2 - What are the benefits of microgrids?Ch. 2 - Prob. CCSQCh. 2 - Prob. DCSQ
Knowledge Booster
Similar questions
- A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and L=40mH. (a) Determine the power factor of the circuit and state whether it is lagging or leading. (b) Determine the real and reactive power absorbed by the load. (c) Calculate the peak magnetic energy Wint stored in the inductor by using the expression Wint=L(Irms)2 and check whether the reactive power Q=Wint is satisfied. (Note: The instantaneous magnetic energy storage fluctuates between zero and the peak energy. This energy must be sent twice each cycle to the load from the source by means of reactive power flows.)arrow_forwardA 2500KVA, 6,600 volts, three-phase wye connected alternator has an effective resistance of 2 ohms and a reactance of 10 ohms per phase. Calculate the per cent voltage regulation at full-load for 0.866 lagging power factor a) Using I phase as a reference vector. b) Using V phase as a reference vector.arrow_forwardQ.1 A 5000 kVA, 6600 V , 3 - phase , star connected alternator has a resistance of 0.75 ohm per phase. Estimate by zero power factor method the regulation for a load of 500 A at power factor (a) unity, (b) 0.9 leading and (c) 0.71 lagging, form the open circuit and full load, zero power factor curves:arrow_forward
- . A 1,500 kVA, 2300 V, 60 Hz, 3 phase, wye-connected generator has a synchronous impedance of 0.06 + j1 ohms/phase. Field current is 60 A at 125 V dc. Find the percent efficiency of the alternator at full load, 2300 V and 0.9 pf lagging at the above condition. The core and friction losses are 25 kW and 18 kW, respectivelyarrow_forwardA straight-line law connects terminal voltage and load of a 3-phase star connected alternator delivering current at 0.8 power factor lagging. At no-load, the terminal voltage is 3,500 V and at full-load of 2,280 kW, it is 3,300 V. Calculate the terminal voltage when delivering current to a 3-phase, star-connected load having a resistance of 8 o and a reactance of 6 ohm per phase. Assume constant speed and field excitation.arrow_forwardA 3 phase mesh-connected AC generator has a power angle of 15.4 degrees and synchronous impedance of 0.5 + j10 per phase while delivering 300A to its load at a lagging power factor and 13,200 volts line to line. Find the no load emf in volts, line to line.arrow_forward
- A 60kVA, 220V, 50Hz, single phase alternator has effective armature resistance of 0.016 ohm and an armature leakage reactance of 0.07 ohm. Compute the voltage induced when the alternator is delivering at a load power factor of (a) unity; a. 225.2V b. 252.2V c. 522.2V d. 222.5Varrow_forwardA 6.6 kV, three-phase, star-connected turbo-alternator of synchronous reactance 0.5ohm/phase is applying 40 MVA at 0.8 lagging p.f. to a large system. If the steamsupply is suddenly cut off, explain what takes place and determine the current themachine will then carry. Neglect losses.arrow_forwardA 6,600V, 1,200 kVA, 3-phase alternator is delivering full load at 0.80 power factor lagging. Its reactance is 25% and resistance is negligible. By changing its excitation, the emf is increased by 30%. At this load, determine the new current and power factor. Draw the single line diagram.arrow_forward
- Given:1. 10 Pole, wye-connected three-phase alternator2. 240 slots 3. 4 turns per coil (lap coils)4. 16/24 pitch5. 8460000 maxwell flux per pole6. 1670 rpm, alternator driven speed Determine the total line - to - line generated voltage. Please show the detailed formula and solution.arrow_forwardA 300 kVA, 6,6 kV, three-phase, star-connected alternator has a percentage impedance of (1,5 + j16,5)%. Calculate for the power factor of 0,8 lagging. a. The ohmic values of the phase resistance and reactance. b. The open-circuit line voltage to which the machine must be excited in order for it to deliver full-load current.arrow_forwardA 3-phase, delta-connected alternator supplies a wye connected load, each phase of which has a resistance of 15 ohm and inductive reactance 20 ohm. If the line voltage is 400 V. calculate (a) the current supplied by the alternator and (b) the output power and kVA rating of the alternator, neglecting any losses in the line between the alternator and the load.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning