Chapter 20, Problem 20.5QAP
Interpretation Introduction

(a)

Interpretation:

The range of the field strengths required is to be stated.

Concept introduction:

A magnetic sector instrument is a mass spectrometer which makes use of a static electric or a magnetic sector. These instruments separate the ions in magnetic field as per the momentum of the ion, charge of the ion and the magnetic field strength. The magnetic field bends the ion beams in an arc.

Interpretation Introduction

(b)

Interpretation:

The range of the accelerating voltages required is to be stated.

Concept introduction:

A magnetic sector instrument is a mass spectrometer which makes use of a static electric or a magnetic sector. These instruments separate the ions in magnetic field as per the momentum of the ion, charge of the ion and the magnetic field strength. The magnetic field bends the ion beams in an arc.

Blurred answer
Students have asked these similar questions
The following data have been obtained in the calibration of a series of standards for the determination of iron, measuring the transmittance, at 506 nm and thickness of 1.00 cm of iron (II) solutions in which color with 1.10 has been developed -phenanthroline. [Fe] (ppm) 0.20 0.40 0.60 0.80 1.00 2.00 3.00 4.00 5.00 6.00 7.00 T (%) 90.0 82.5 76.0 69.5 63.5 41.0 26.3 17.0 10.9 7.0 4.5 Calculate the mean molar absorptivity of iron when determined by this method.
A Dubosq colorimeter consists of a cell of fixed path length and a cell of variable path length. By adjusting the length of the latter until the transmission through the two cells is the same. the concentration of the second solution can be inferred from that of the former. Suppose that a plantdye of concentration 25 μg dm-3 is added to the fixed cell. the length of which is 1.55 em. Then a solution of the same dye. but of unknown concentration. is added to the second cel l. It is found that the same t ransmittance is obtained when the length of the second cel l is adjusted to 1.18 em. What is the concentration of the second solution?
What accelerating voltage would be needed to analyze for C6H6+ (MW = 78.11) using a magnetic sector mass spectrometer, if it required 1144V to detect CO2+ (MW = 44.00)?
Knowledge Booster
Background pattern image
Chemistry
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Text book image
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Text book image
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning