Question
Chapter 21, Problem 21.3QAP
Interpretation Introduction
Interpretation:
The reason of containing the information from an XPS chemical shift in an X-ray absorption edge should be determined.
Concept introduction:
The minimum energy required to remove an electron from its orbit to a reason where it does not feel the effect of nuclear charge is called XPS binding energy.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
The chemical shift value (δ) is measured by the ratio of shift in Hertz and the operational frequency of the spectrometer in MHz, give the equation to calculate the shift value
7. Explain what is meant by signal in instrumental analysis.
What percent transmittance range and what absorbance range are considered to be the optimum working ranges for spectrochemical measurements?
Chapter 21 Solutions
Principles of Instrumental Analysis, 6th Edition
Knowledge Booster
Similar questions
- state the relationship between absorbance and transmittancearrow_forwardA student calibrated the mini-spectrophotometer with a blank solution, and then went to check their solution. They got a fingerprint on the cuvette while filling it. Because of this, the expected reading for the absorbance would be too high which would cause the calculated value of K, to be too higharrow_forward3. In molecular absorption spectrophotometry, the relationship between transmittance and concentration is not linear while the absorbance vs concentration is linear. True Falsearrow_forward
- The levels of Vitamin B1 in a sample of milk was determined using the Standard Addition method and technique of fluorescence spectroscopy. 18.0 ml of the milk sample was diluted to 20.0 ml using distilled water and then the fluorescence was measured. The resulting signal was 210 units. A spike was made by taking 18.0 ml of the same milk sample, adding 1.0 ml of a 6.0 ppm Vitamin B1 standard solution, and then diluting to 20.0 ml using distilled water. The signal of the spiked milk was 540 units. Calculate the concentration of Vitamin B1 in the original milk sample (in ppm). Report to 3 decimal places.arrow_forwardIdentify and provide an explanation of the operational principles behind an Atomic Absorption Spectrometer.arrow_forwardWhat length of mirror drive in a Michelson interferometer is required to produce a resolution sufficient to separate (a) IR peaks at 600.7 and 600.4 cm-1?arrow_forward
- A solution with a known concentration equal to 3.4 mM gave an absorbance reading of 0.820 in a spectrophotometer. Assuming that there isa linear relationship between concentration and absorbance up to a concentration of 4.0 mM, what would the absorbance reading be for asolution with a concentration 1.5 mM?arrow_forwardA spectrophotometer has basic several components. Describe the role of each component and the justification for the setup of an instrument used for excitation spectroscopy and an instrument for emission spectroscopy.arrow_forwardSuppose you are analyzing mercury ions (Hg2+) in drinking water samples with atomic absorption spectroscopy. If the Hg2+ signal varies by a matrix of sample, which of the following should be used as a standard for calibration? Either cations or anions can be used if they are different from Hg2+, 0 H20 Any anions can be used if they are different from Hg2+ Any cations can be used if they are different from Hg?". Hg2+arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781337398909Author:Lawrence S. Brown, Tom HolmePublisher:Cengage Learning
- Physical ChemistryChemistryISBN:9781133958437Author:Ball, David W. (david Warren), BAER, TomasPublisher:Wadsworth Cengage Learning,Principles of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Chemistry for Engineering Students
Chemistry
ISBN:9781337398909
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning
Physical Chemistry
Chemistry
ISBN:9781133958437
Author:Ball, David W. (david Warren), BAER, Tomas
Publisher:Wadsworth Cengage Learning,
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning