The conductor sizes, overload heater size, circuit breaker size, fuse size, minimum NEMA and IEC starter sizes, and the upper and lower range of starting current for this motor.
Explanation of Solution
Given:
Horsepower of the motor
Line voltage
Power factor
Full-load current
A temperature rise
Three phase synchronous motor.
Code letter is
Conductor is copper wire with THHN insulation.
Transformer ratio
Calculate the maximum ampacity
Refer to Table 310.15(B)(16), “Conductor sizes” to obtain the size of conductor as
Refer to Table 430.52, “Percentage of full load current” to obtain the percentage full-load current as
Refer to Figure 21-19, “Fuse size” to obtain the fuse size as
Refer to Figure 21-21, “IEC motor starter by size, horsepower” to obtain the size of IEC starter as
Refer to Figure 21-20, “NEMA motor starter sizes” to obtain the size of IEC starter as
Refer to Table 430.7(B) “Locked-Rotor indicating code” to obtain the upper and lower range of starting current as
Calculate the upper limit
Calculate the lower limit
Thus, the conductor size is
Want to see more full solutions like this?
Chapter 21 Solutions
Electrical Transformers and Rotating Machines
- A 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forwardIf dual-element time delay fuses are to be used as the short circuit protective device, what size fuses should be used to protect the circuit in question #12? Five 5 HP, three-phase motors with NEMA code B are connected to a 240-volt line. The conductors are copper with type THWN insulation. What size conductor should be used to supply all of these motors?arrow_forwardTwo transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forward
- A 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forwardIn a given DC motor, the output power is 20 HP, and the copper losses are 1.1 KW. If the motor is operating at 87 % efficiency, find the converted power and the rotational losses. Select one: a. Pconv = 16.05 KW and Prot = 1.13 KW b. Pconv = 17.15 KW and Prot = 3.11 KW c. Pconv = 14.92 KW and Prot = 1.35 KW d. Nonearrow_forwardLarge transformers, when used for some time, become very hot and are cooled by circulating oil. The heating of the transformer is due to: A. the heating effect of current alone B. hysteresis loss alone C. both the heating effect of current and hysteresis loss D. intense sunlight at noonarrow_forward
- An 8 pole, lap connected armature has 500 conductors and its generated e.m.f is 120V. If the flux per pole is 20 mWb, then the speed of machine is,arrow_forwardThe input power to a 3-phase load is measured as 6700 watts. If the line voltage and line current to the load are 430 V and 18 A respectively. The power factor of the System is,arrow_forwardA 4-pole shunt generator with wave-wound armature has 41 slots, each having 12 conductors. The armature resistance is 0.05 ohms and shunt field resistance s 200 ohms. The flux per pole is 25 mWb, if a load resistance of 10 ohms is connected across the armature terminals, calculate the voltage across the load when generator is driven at 1000 rpmarrow_forward
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage Learning