Question
Chapter 24, Problem 46P
To determine
(a)
To sketch:
The connections required to the measure the total watts delivered to the load using three watt-meter.
To determine
(b)
The total wattage dissipation and the reading of each wattmeter.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Suppose three equal loads of 25<30° are Δ connected. The terminal voltage of impedances is 6.9 kV. If impedance of each transmission line connecting each load to a bus is 2<65°. What is the terminal voltage of the substation bus?
Calculate the line and phase current drawn by the load and the power factor.
A three phase transmission line to line capacitive reactance value is 12 ohms. If the charging current of a line per phase is 37 A. Choose the corresponding phase voltage from the values given below.
21.07V
0.32V
444.00V
256.34V
Chapter 24 Solutions
EBK INTRODUCTORY CIRCUIT ANALYSIS
Ch. 24 - A balanced V load having a 10 resistance in each...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - The phase sequence for the Y-Y system in Fig....Ch. 24 - Repeat Problem 4 if each phase impedance are...Ch. 24 - Repeat Problem 4 if each phase impedance is...Ch. 24 - For the system in Fig. 24.43, find the magnitude...Ch. 24 - Computer the magnitude of the voltage EAB for the...Ch. 24 - For the Y-Y system in Fig. 24.45: a. Find the...Ch. 24 - For the Y-Y system of Fig. 24.46 the impedance of...
Ch. 24 - A balanced load having a 20 resistance in each...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - The phase sequence for the Y- system in Fig....Ch. 24 - Repeat Problem 14 if each phase impedance is...Ch. 24 - Repeat Problem 14 if each phase impedance are...Ch. 24 - Prob. 17PCh. 24 - For the connected load in Fig. 24.49: a. Find the...Ch. 24 - A balanced V load having a 30 resistance in each...Ch. 24 - Repeat Problem 19 if each phase impedance is...Ch. 24 - Prob. 21PCh. 24 - Prob. 22PCh. 24 - Prob. 23PCh. 24 - Repeat Problem 22 if each phase impedance is...Ch. 24 - Prob. 25PCh. 24 - Prob. 26PCh. 24 - Prob. 27PCh. 24 - The phase sequence for the - system in Fig....Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Prob. 31PCh. 24 - Prob. 32PCh. 24 - Prob. 33PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 35PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 38PCh. 24 - Prob. 39PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - A balanced, three-phase, -connected load has a...Ch. 24 - A balanced, three-phase, Y-connected load has a...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - The Y-Y system in Fig. 24.53 has a balanced load...Ch. 24 - Prob. 45PCh. 24 - Prob. 46PCh. 24 - Repeat Problem 46 for the network in Fig. 24.47.Ch. 24 - For the three-wire system in Fig. 24.55, properly...Ch. 24 - Sketch three different ways that two wattmeters...Ch. 24 - For the Y- system in Fig. 24.56: Determine the...Ch. 24 - For the system in Fig. 24.57: Calculate the...Ch. 24 - For the three-phase, three-wire system in Fig....
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A three phase balanced load having a power factor of 0.52 lagging draws a line current of 25A at 220V. If the two watt-meter method is used to measure the total power consumed, determine the reading of each wattmeter.arrow_forwardFigure 4.37 shows the conductor configuration of a three-phase transmission line and a telephone line supported on the same towers. The power line carries a balanced current of 250 A/phase at 60 Hz, while the telephone line is directly located below phase b Assume balanced three-phase currents in the power line. Calculate the voltage per kilometer induced in the telephone line.arrow_forward1.) A three phase, 3 wire CBA system, with the line voltage Vab =300cis0°,has the following line currents: Ia= 60cis120°, Ib= 62cis-45°,Ic= 15.5cis220° Find the readings of wattmeters in lines a.) A and B b.) B and C C.) A and Carrow_forward
- In the experiment No.1, the power measurement using two wattmeter method for delta connected load, the value of line current is 3–√3 of phase current. Select one: True Falsearrow_forwardA minimum of three wattemer should be used to measure power for a three phase balanced system. True Falsearrow_forwardA balanced 3 phase load draws 75 amperes line current at 230 volts line to line and 0.848 lagging power factor. If the two wattmeter method is used, solve for the readings of the wattmeter.arrow_forward
- The appropriate locality for the power factor improvement device is a. At the sending end. b. Near the electrical appliance which is responsible for the poor power factor. and At the receiving end in case of transmission lines. c. At the receiving end in case of transmission lines. d. Near the electrical appliance which is responsible for the poor power factor.arrow_forwardThe resistance and reactance of the single-phase 60Hz transmission line conductors are 7.6 ohm and 6.6 ohm respectively. The transmission line delivers 20MW at a power factor of 0.66 lagging to the load with 54kV receiving end voltage. Determine the following a) The inductance of the transmission line in mH b) Sending end power factor c) Percentage voltage regulation d) Percentage Efficiencyarrow_forwardA single phase transmission line is delivering 410 kVA load at 10 kV. Its resistance is 5.5 ohm and inductive reactance is 8 ohm if the load power factor is 0.7 lagging. Determine the Current through the line Sending end voltage Sending end power factor Regulation of transmission line Efficiency of transmission linearrow_forward
- The resistance and reactance of the single-phase 60Hz transmission line conductors are 5.4 ohm and 7.4 ohm respectively. The transmission line delivers 45MW at a power factor of 0.65 lagging to the load with 54kV receiving end voltage. Determine the following The inductance of the transmission line in mH Sending end power factor Percentage voltage regulation Percentage Efficiencyarrow_forwardtwo wattmeters are connected to measure the input power to a balanced 3-phase load by two wattmeter method, If the total power input is 12kW, and the load power factor is 0.866(lag) determine the instrument readings.arrow_forwardA short 3-phase transmission line connected to a 33kV, 50 Hz generating station at the sending end is required to supply a load of 10 MW at 0.8 lagging power factor at 30 kV at the receiving end. If the minimum transmission efficiency is to be limited to 96%, estimate the per phase value of resistance and inductance of the line.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Fault Analysis in Power Systems part 1a; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=g8itg4MOjok;License: Standard youtube license