EBK INTRODUCTORY CIRCUIT ANALYSIS
13th Edition
ISBN: 8220100668234
Author: Boylestad
Publisher: PEARSON
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 24, Problem 48P
For the three-wire system in Fig. 24.55, properly connect a second wattmeter so that the two measure the total power delivered to the load.
Fig. 24.55
b. If one wattmeter has a reading of 220 W and the other a reading of 85 W, what is the total dissipation in watts if the total power factor is 0.8 leading?
c. Repeat part (b) if the total power factor is 0.2 lagging and
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A three phase balanced load having a power factor of 0.52 lagging draws a line current of 25A at 220V. If the two watt-meter method is used to measure the total power consumed, determine the reading of each wattmeter.
A single wattmeter is connected to measure reactive power of a three-phase, three-wire balanced load. The line current is 17 A and the line voltage is 440 V. Calculate the power factor of the load if the reading of the wattmeter is 4488 VAR.
A 3-phase, delta-connected alternator supplies a wye connected load, each phase of which has a resistance of 15 ohm and inductive reactance 20 ohm. If the line voltage is 400 V. calculate (a) the current supplied by the alternator and (b) the output power and kVA rating of the alternator, neglecting any losses in the line between the alternator and the load.
Chapter 24 Solutions
EBK INTRODUCTORY CIRCUIT ANALYSIS
Ch. 24 - A balanced V load having a 10 resistance in each...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - The phase sequence for the Y-Y system in Fig....Ch. 24 - Repeat Problem 4 if each phase impedance are...Ch. 24 - Repeat Problem 4 if each phase impedance is...Ch. 24 - For the system in Fig. 24.43, find the magnitude...Ch. 24 - Computer the magnitude of the voltage EAB for the...Ch. 24 - For the Y-Y system in Fig. 24.45: a. Find the...Ch. 24 - For the Y-Y system of Fig. 24.46 the impedance of...
Ch. 24 - A balanced load having a 20 resistance in each...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - The phase sequence for the Y- system in Fig....Ch. 24 - Repeat Problem 14 if each phase impedance is...Ch. 24 - Repeat Problem 14 if each phase impedance are...Ch. 24 - Prob. 17PCh. 24 - For the connected load in Fig. 24.49: a. Find the...Ch. 24 - A balanced V load having a 30 resistance in each...Ch. 24 - Repeat Problem 19 if each phase impedance is...Ch. 24 - Prob. 21PCh. 24 - Prob. 22PCh. 24 - Prob. 23PCh. 24 - Repeat Problem 22 if each phase impedance is...Ch. 24 - Prob. 25PCh. 24 - Prob. 26PCh. 24 - Prob. 27PCh. 24 - The phase sequence for the - system in Fig....Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Prob. 31PCh. 24 - Prob. 32PCh. 24 - Prob. 33PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 35PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 38PCh. 24 - Prob. 39PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - A balanced, three-phase, -connected load has a...Ch. 24 - A balanced, three-phase, Y-connected load has a...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - The Y-Y system in Fig. 24.53 has a balanced load...Ch. 24 - Prob. 45PCh. 24 - Prob. 46PCh. 24 - Repeat Problem 46 for the network in Fig. 24.47.Ch. 24 - For the three-wire system in Fig. 24.55, properly...Ch. 24 - Sketch three different ways that two wattmeters...Ch. 24 - For the Y- system in Fig. 24.56: Determine the...Ch. 24 - For the system in Fig. 24.57: Calculate the...Ch. 24 - For the three-phase, three-wire system in Fig....
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The three windings of a three phase, 60 Hz AC generator are connected in wye. Each of the three coil windings is rated at 5000 VA and 120 V. Determine: the line voltage. the line current when the generator is delivering its full-load output. the full-load rating of the three-phase generator, in kilovolt-amperesarrow_forwardtwo wattmeters are connected to measure the input power to a balanced 3-phase load by two wattmeter method, If the total power input is 12kW, and the load power factor is 0.866(lag) determine the instrument readings.arrow_forward31. A 3-phase 3-wire star-connected load consists of a capacitive reactance of 100ohm in the red phase and a resistor of 100ohm in Bo- each of the other phases. The line voltage is 440 V and the phase sequence is RYB. If the power is measured by the 2-wattmeter method,the current coils being connected in the red and yellow leads respectively, determine the reading of each instrument. (-86.5 W, 1.640 W) Answerarrow_forward
- In the experiment No.1, the power measurement using two wattmeter method for delta connected load, the value of line current is 3–√3 of phase current. Select one: True Falsearrow_forwardA factory that is fed by a three-phase generator connected in Δ with Vac equal to 240 V with an angle of 30 degrees and negative sequence, has two balanced inductive loads both connected in Y with R = 2.4 Ω and XL = 3 Ω each. Calculate all the line currents leaving the generator to the two loads and show this process.arrow_forwardQ23/ In the balanced three phase power measurement using two wattmeter method, each wattmeter reads 18 kW , when the pf is unity. What does each wattmeter reads when the pf falls to (i) 0.6 lag and (ii) 0.422 lag. The total three-phase power remains unchanged.arrow_forward
- The load to the three phase supply comprises three similar coils connected in Star. The line current are 25Amperes and the KVA and KW inputs are 20 and 11 respectively. Find , The phase and line voltage, The KVAR input, The resistance and reactance of each coils.arrow_forwardAssume the load on the substation bus drops to 240 kW and 600 magnetizing kVAR. Also assume the capacitors remain connected to the substation. 1. a) What is the magnitude of the line-to-line voltage at the generating plant that is required to maintain a line-to-line voltage of 13.8 kV at the substation? 2. b) Will this power plant voltage level cause problems for other customers?arrow_forwardThe Power output to a three-phase load is found to be 15kW using two-watimeter method, Calculate The Power input if the efficiency is 85% The Power Factor The reading of each watt-meter if the power factor of the system is 0.95arrow_forward
- It is desired to correct the 2,400-kVa 0.65 lagging power factor load in a plantto unity by the installation of a synchronous condenser. Calculate the kilovoltampere rating of the latter. Ans.: 1824 kVAarrow_forwardThe power input to a three-phase motor is measured by the two wattmeter method. The three line voltages are 220 V and the current in each of the three line wires is 8 A. If the three-phase power factor is 0.866 lag, what are the values of power indicated by wattmeter 1 and wattmeter 2arrow_forwardIn the single-phase power system below, determine the voltage, Vab, and current, Iab, being received by the load, 10 + j15 Ω.Answer Format::"Vab = XX.XXXX cis XX.XX V" "Iab = XX.XXXX cis XX.XX A"arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Electrical Measuring Instruments - Testing Equipment Electrical - Types of Electrical Meters; Author: Learning Engineering;https://www.youtube.com/watch?v=gkeJzRrwe5k;License: Standard YouTube License, CC-BY
01 - Instantaneous Power in AC Circuit Analysis (Electrical Engineering); Author: Math and Science;https://www.youtube.com/watch?v=If25y4Nhvw4;License: Standard YouTube License, CC-BY