Chapter 3, Problem 3.33P
Consider the three single-phase two-winding transformers shown in Figure 3.37. The high-voltage windings are connected in Y. (a) For the low-voltage side, connect the windings in
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
10
A three-phase transformer is given. The number of turns of the high voltage winding is
N1=850 and the number of turns of the low voltage winding is N2=34. The high voltage
winding is energized with V1= 10 kV rms line-to-line and V2= 400 V rms line-to-line has been
taken from the low voltage winding. What is the connection of the low voltage winding if the
high voltage winding is Y-connected?
Εισαγάγετε την απάντησή σας
A three-phase transformer is given. The number of turns of the high voltage
winding is N1=850 and the number of turns of the low voltage winding is
N2=34. The high voltage winding is energized with V1= 10 kV rms line-to-line
and V2= 400 V rms line-to-line has been taken from the low voltage winding.
What is the connection of the low voltage winding if the high voltage winding
is Y-connected? *
In the circuit in Figure 2, the capacitor connected to the a-b terminals of the transformer anda circuit consisting of resistance is defined as a load circuit.
a)Find the average power spent by the load circuit?
b) How much of the average power calculated in a) by the resistance in the load circuit and how muchspent by the capacitor? Comment on the results obtained?
Chapter 3 Solutions
MindTap Engineering, 1 term (6 months) Printed Access Card for Glover/Overbye/Sarma's Power System Analysis and Design, 6th
Ch. 3 - The Ohms law for the magnetic circuit states that...Ch. 3 - For an ideal transformer, the efficiency is (a) 0...Ch. 3 - For an ideal 2-winding transformer, the...Ch. 3 - An ideal transformer has no real or reactive power...Ch. 3 - For an ideal 2-winding transformer, an impedance...Ch. 3 - Consider Figure 3.4. For an ideal phase-shifting...Ch. 3 - Consider Figure 3.5. Match the following, those on...Ch. 3 - The units of admittance, conductance, and...Ch. 3 - Match the following: (i) Hysteresis loss (a) Can...Ch. 3 - For large power transformers rated more than 500...
Ch. 3 - For a short-circuit test on a 2-winding...Ch. 3 - The per-unit quantity is always dimensionless. (a)...Ch. 3 - Consider the adopted per-unit system for the...Ch. 3 - The ideal transformer windings are eliminated from...Ch. 3 - To convert a per-unit impedance from old to new...Ch. 3 - In developing per-unit circuits of systems such as...Ch. 3 - Prob. 3.17MCQCh. 3 - Prob. 3.18MCQCh. 3 - With the American Standard notation, in either a...Ch. 3 - Prob. 3.20MCQCh. 3 - In order to avoid difficulties with third-harmonic...Ch. 3 - Does an open connection permit balanced...Ch. 3 - Does an open- operation, the kVA rating compared...Ch. 3 - It is stated that (i) balanced three-phase...Ch. 3 - In developing per-unit equivalent circuits for...Ch. 3 - In per-unit equivalent circuits of practical...Ch. 3 - Prob. 3.27MCQCh. 3 - Prob. 3.28MCQCh. 3 - For developing per-unit equivalent circuits of...Ch. 3 - Prob. 3.30MCQCh. 3 - Prob. 3.31MCQCh. 3 - Prob. 3.32MCQCh. 3 - The direct electrical connection of the windings...Ch. 3 - Consider Figure 3.25 of the text for a transformer...Ch. 3 - (a) An ideal single-phase two-winding transformer...Ch. 3 - An ideal transformer with N1=1000andN2=250 is...Ch. 3 - Consider an ideal transformer with...Ch. 3 - A single-phase 100-kVA,2400/240-volt,60-Hz...Ch. 3 - Prob. 3.5PCh. 3 - Prob. 3.6PCh. 3 - Consider a source of voltage v(t)=102sin(2t)V,...Ch. 3 - Prob. 3.8PCh. 3 - Prob. 3.9PCh. 3 - A single-phase step-down transformer is rated...Ch. 3 - For the transformer in Problem 3.10. The...Ch. 3 - Prob. 3.12PCh. 3 - A single-phase 50-kVA,2400/240-volt,60-Hz...Ch. 3 - A single-phase 50-kVA,2400/240-volt,60-Hz...Ch. 3 - Rework Problem 3.14 if the transformer is...Ch. 3 - A single-phase, 50-kVA,2400/240-V,60-Hz...Ch. 3 - The transformer of Problem 3.16 is supplying a...Ch. 3 - Using the transformer ratings as base quantities,...Ch. 3 - Using the transformer ratings as base quantities....Ch. 3 - Using base values of 20 kVA and 115 volts in zone...Ch. 3 - Prob. 3.21PCh. 3 - A balanced Y-connected voltage source with...Ch. 3 - Figure 3.32 shows the oneline diagram of a...Ch. 3 - For Problem 3.18, the motor operates at full load,...Ch. 3 - Consider a single-phase electric system shown in...Ch. 3 - A bank of three single-phase transformers, each...Ch. 3 - A three-phase transformer is rated...Ch. 3 - For the system shown in Figure 3.34. draw an...Ch. 3 - Consider three ideal single-phase transformers...Ch. 3 - Reconsider Problem 3.29. If Va,VbandVc are a...Ch. 3 - Prob. 3.31PCh. 3 - Determine the positive- and negative-sequence...Ch. 3 - Consider the three single-phase two-winding...Ch. 3 - Three single-phase, two-winding transformers, each...Ch. 3 - Consider a bank of this single-phase two-winding...Ch. 3 - Three single-phase two-winding transformers, each...Ch. 3 - Three single-phase two-winding transformers, each...Ch. 3 - Consider a three-phase generator rated...Ch. 3 - The leakage reactance of a three-phase,...Ch. 3 - Prob. 3.40PCh. 3 - Consider the single-line diagram of the power...Ch. 3 - For the power system in Problem 3.41, the...Ch. 3 - Three single-phase transformers, each rated...Ch. 3 - A 130-MVA,13.2-kV three-phase generator, which has...Ch. 3 - Figure 3.39 shows a oneline diagram of a system in...Ch. 3 - The motors M1andM2 of Problem 3.45 have inputs of...Ch. 3 - Consider the oneline diagram shown in Figure 3.40....Ch. 3 - With the same transformer banks as in Problem...Ch. 3 - Consider the single-Line diagram of a power system...Ch. 3 - A single-phase three-winding transformer has the...Ch. 3 - The ratings of a three-phase three-winding...Ch. 3 - Prob. 3.52PCh. 3 - The ratings of a three-phase, three-winding...Ch. 3 - An infinite bus, which is a constant voltage...Ch. 3 - A single-phase l0-kVA,2300/230-volt,60-Hz...Ch. 3 - Three single-phase two-winding transformers, each...Ch. 3 - A two-winding single-phase transformer rated...Ch. 3 - A single-phase two-winding transformer rated...Ch. 3 - Prob. 3.59PCh. 3 - PowerWorid Simulator case Problem 3_60 duplicates...Ch. 3 - Rework Example 3.12 for a+10 tap, providing a 10...Ch. 3 - A 23/230-kV step-up transformer feeds a...Ch. 3 - The per-unit equivalent circuit of two...Ch. 3 - Reconsider Problem 3.64 with the change that now...Ch. 3 - What are the advantages of correctly specifying a...Ch. 3 - Why is it important to reduce the moisture within...Ch. 3 - What should be the focus of transformer preventive...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- An ideal transformer has no real or reactive power loss. (a) True (b) Falsearrow_forwardConsider the three single-phase two-winding transformers shown in Figure. 3. The high-voltage windings are connected in Y. (a) For the low-voltage side, connect the windings in A, and label the terminals a, b, and c in accordance with the American standard. (b) Relabel the terminals a', b', and c' such that VAN is 90° out of phase with V₂'b' for positive sequence. DI H₂ Figure. 3: Three-Winding Transformerarrow_forward3) Obtain the relationships between terminal voltages and currents for each of the ideal transformers in the figures below. I2 I2 1:n 1:n V1 V2 Vị V2 (b) (a) I1 I2 I1 I2 1:n 1:n V1 V2 V1 V2 (c) (d)arrow_forward
- In the circuit in Figure 2, the capacitor connected to the a-b terminals of the transformer anda circuit consisting of resistance is defined as a load circuit. Find the average power spent by the load circuit?arrow_forward. A 400/230V, 50Hz, single phase transformer has 200 turns on high voltage side. Find turns ratio, transformation ratio, and number of turns on low voltage winding. Also find the flux developed in the corearrow_forwardA 50 Hz, 1-phase transformer has a turn ratio of 6. The resistances are 0.9 ohm and 0.03 ohm and reactances are 5 ohm and 0.13 ohm for high voltage and low voltage windings respectively. Find (i) the voltage to be applied to the h.v. side to obtain full-load current of 200 A in the l.v. winding on short circuit (ii) the power factor on short circuit.arrow_forward
- The resistance and reactance of the primary winding of a 440/110 V single phase transformer are 4.4 ohm and 8 ohm respectively. The resistance and reactance of the secondary winding are 1.6 ohm and 2ohm respectively. Then find the equivalent resistance, reactance and impedance referred to the primary side.arrow_forwardA voltage transformer in Figure 8 has 1,500 turns of wire on its primary winding and 500 turns of wire for its secondary winding. What will be the turns ratio, a of the transformer. If 240 volts is applied to the primary winding, what will be the resulting secondary voltage. And if a 400 n resistor is connected to the secondary winding, what are the values of current Is and Ip. primary Vp Transformer Core NF Ns Figure 8 secondary Vsarrow_forwardThe primary ofa certain transformer takes 1 A at a power factor of 0.4 when connected across a 230 V, 50 Hz supply and the secondary is on open circuit. The number of turns on the primary is twice that on the secondary. A load taking 50 A at a lagging power factor of 0.8 is now connected across the secondary. Sketch, and explain briefly, the phasor diagram for this condition, neglecting voltage drops in the transformer. What is now the value of the primary current?arrow_forward
- The core of a transformer operating at 50 Hz has an eddy current loss of 100 W/m3 and the corelaminations have a thickness of 0.50 mm. The core is redesigned so as to operate with the same eddycurrent loss but at a different voltage and at a frequency of 250 Hz. Assuming that at the new voltage themaximum flux density is one-third of its original value and the resistivity of the core remains unaltered,determine the necessary new thickness of the laminations. Clear and detailed solution.arrow_forwardChapman Problem 3-4. A single-phase power system is shown in the figure below. The power source feeds a 100-kVA, 14/2.4-kV transformer through a feeder impedance of 38.2 + j140 N. The transformer's equivalent series impedance referred to its low-voltage is 0.12 + j0.5 N. The load on the transformer is 90 kW at 0.85 PF lagging and 2300V. а. What is the voltage at the power source of the system? b. What is the voltage regulation of the transformer? How efficient is the overall power system? С.arrow_forwardWhat are the two component of no load current of transformer and write its equation (Rule)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
TRANSFORMERS - What They Are, How They Work, How Electricians Size Them; Author: Electrician U;https://www.youtube.com/watch?v=tXPy4OE7ApE;License: Standard Youtube License