HEATING, VENTILATING,+AC ANAL...EBOOK>I<
6th Edition
ISBN: 2819480255750
Author: Mcquiston
Publisher: INTER WILE
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 3, Problem 3.50P
A water coil in Problem 3-48 cools return air to the cold deck condition. Determine the coil load (for the one zone) and sketch the processes for the entire system on a psychrometric chart. Find the volume flow rate entering the coil in (a) English units and (b) SI units.
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Want to see the full answer?
Check out a sample textbook solution![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
No. 3 question:
A diesel engine powers a boat. The engine’s cylinders each have a cut-offratio(V3/V2) of 2 and the V3is 4ft3. If 1 cylinder is in the isobaric expansionstroke, find the final temperature if the initial temperature is 540F
Main question:
From number 3, if the gas tankaccident happened on top of Mt. Everest’s summit where patm is only 33.7 kpaand the readings obtained are the same, find the new final temperature
17) What is the approximate Peritectic Temperature for the system?
Time constant of thermocouple is 5 milliseconds. An engineer measures
the temperature of water and sees that the temperature is less than the
real temperature of the boiling water (100 C). How long does the engineer
need to wait at least to see the 98 C?
none of the above
20 milliseconds
10 milliseconds
15 milliseconds
not sufficient information
17 milliseconds
Chapter 3 Solutions
HEATING, VENTILATING,+AC ANAL...EBOOK>I<
Ch. 3 - A space is at a temperature of 75 F (24 C), and...Ch. 3 - Determine the humidity ratio, enthalpy, and...Ch. 3 - Suppose the air of Problem 3-2 is at a pressure...Ch. 3 - What is the enthalpy of moist air at 70 F (20 C)...Ch. 3 - The inside surface temperature of a window in a...Ch. 3 - What is the mass flow rate of dry air flowing at a...Ch. 3 - Determine the dew point of moist air at 80 F (27...Ch. 3 - A room is to be maintained at 72 F (22 C) db. It...Ch. 3 - Air is cooled from 80 F db and 67 F wb until it is...Ch. 3 - Conditions in a room are measured to be 80 F db...
Ch. 3 - The environmental conditions in a room are to be...Ch. 3 - Air enters a cooling coil at the rate of 5000 cfm...Ch. 3 - Air flowing in a duct has dry and wet bulb...Ch. 3 - Air is humidified with the dry bulb temperature...Ch. 3 - Air at 38 C db and 20 C wb is humidified...Ch. 3 - Two thousand cfm (1.0 m3/s) of air at an initial...Ch. 3 - Air at 40 F (5 C) db and 35 F (2 C) wb is mixed...Ch. 3 - Rework Problem 3-25, using Chart 1a, with the...Ch. 3 - The design cooling load for a zone in a building...Ch. 3 - Assume that the air in Problem 3-22 is supplied to...Ch. 3 - The sensible heat loss from a space is 500,000...Ch. 3 - Air enters a refrigeration coil at 90 Fdb and 75...Ch. 3 - A building has a total heating load of 200,000...Ch. 3 - Reconsider Problem 3-36 for an elevation of 5000...Ch. 3 - The system of Problem 3-34 has a supply air fan...Ch. 3 - An evaporative cooling system is to be used to...Ch. 3 - A cooling system is being designed for use at high...Ch. 3 - Consider a space heating system designed as shown...Ch. 3 - A variable-air-volume VAV cooling system is a type...Ch. 3 - Rework Problem 3-43 for an elevation of 5000 feet...Ch. 3 - The design condition for a space is 77 F (25 C) db...Ch. 3 - Rework Problem 3-45 for an elevation of 5000 feet...Ch. 3 - It is necessary to cool and dehumidify air from 80...Ch. 3 - Conditions in one zone of a dual-duct conditioning...Ch. 3 - Rework Problem 3-48 for an elevation of 5000 ft...Ch. 3 - A water coil in Problem 3-48 cools return air to...Ch. 3 - A multizone air handler provides air to several...Ch. 3 - Under normal operating conditions a zone has a...Ch. 3 - An interior zone of a large building is designed...Ch. 3 - Outdoor air is mixed with room return air to...Ch. 3 - Consider an enclosed swimming pool. The pool area...Ch. 3 - One particular zone served by a multizone air...Ch. 3 - A research building requires 100 percent outdoor...Ch. 3 - A space requires cooling in the amount of 120,000...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
What parts are included in the vehicle chassis?
Automotive Technology: Principles, Diagnosis, and Service (5th Edition)
Determine the force in members BC, CF, and FE and state if the members are in tension or compression. Prob. F5-...
Statics and Mechanics of Materials (5th Edition)
3.58 The transmission tower shown is subjected to a horizontal wind force of 400 lb acting at point B. Support ...
Applied Statics and Strength of Materials (6th Edition)
The temperature of water at outlet.
Introduction to Heat Transfer
What are some of the common causes for failure of mechanically fastened joints?
Degarmo's Materials And Processes In Manufacturing
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 4. If the chilled water is being supplied at 45°F, and the coil is selected so that the chilled water temperature rise is 10°F, what is the required chilled water flow through the coil in GPM?arrow_forward* It required to design a ducting system to condition the building shown in figure (1). The uantity of outdoor is (20%) of supply air. Using information in table, find 1- The sensible and latent load for cooling coil. 2- The quantity and condition of supply air to each place. 3- By using equal pressure drop method, design the rectangular ducting system with maximum height side (600mm). 4- Illustrate the all process on psychometric chart. Outdoor 45 °C db & 30% RH Out let type Celling conditioning indoor conditioning 24 °C db & 50% RH diffuser Number of diffuser 2 for each place 15 kpa 10 kpa 15 kpa By pass factor Apparatus dew point 9°C Ap losses diffuser Ap losses filter Ap losses coil 0.15 R/w 1.5 бm бm бm Room (1) Room (2) RSH=6KW Room (3) 4m RSH=8KW RSH=8KW RLH=2KW RLH=1KW RLH=2KW 2m AHU Mechanical Room (4) RSH=20KW 4m Room RLH=3KW 4m 14marrow_forward* It required to design a ducting system to condition the building shown in figure (1). The uantity of outdoor is (20%) of supply air. Using information in table, find 1- The sensible and latent load for cooling coil. 2- The quantity and condition of supply air to each place. 3- By using equal pressure drop method, design the rectangular ducting system with maximum height side (600mm). 4- Illustrate the all process on psychometric chart. Outdoor 45 °C db & 30% RH Out let type Celling conditioning indoor conditioning 24 °C db & 50% RH diffuser Number of diffuser 2 for each place 15 kpa 10 kpa 15 kpa By pass factor Apparatus dew point 9°C Ap losses diffuser Ap losses filter Ap losses coil 0.15 R/w 1.5 6m 6m 6m Room (1) Room (2) Room (3) 4m RSH=8KW RSH=6KW RSH=8KW RLH=2KW RLH=1KW RLH=2KW 2m AHU Mechanical Room (4) RSH=20KW 4m Room RLH=3KW 4m 14marrow_forward
- If 14 gpm of water is flowing through an open-loop heatpump with a temperature difference of 78F, how muchheat in Btu/h is being absorbed or rejected in the heatpump? Show all work and units.arrow_forwardA Thomas meter is located in an air duct of 2 sq ft cross-sectional area. The air weighs 0.083 lb per cu ft, and its specific heat is 0.24. Assume a controlled temperature differential of 5° and heater potential of 110 volts. Plot the velocity as abscissa and amperage as ordinate for veloc- ity 0 to 300 ft per min. Assume constant amperage of 3, and plot tem- perature difference against velocity. Discuss the curves from the stand- point of accuracy of the system.arrow_forwardThree water coils are connected in parallel. The water supplied to the coils feeds into a commonreturn line. The first coil feeds 60 gpm of 125 o F water into the return line. The second coil feeds 50gpm of 120 o F water into the line. The third coil feeds 50 gpm of 118 o F water into the commonreturn line. What is the temperature of the water in the common line after the three streams ofwater mix?arrow_forward
- Please answer questions g, h, and i. g.Calculate the heat transferred in the condenser. h.Calculate the diameter of the pipe connecting the turbine to the condenser. Design data for the plant shows the following pipe diameters. i. Calculatecooling water flow rate in GPM (‘gallons per minute’)through the condenser if the temperature of the cooling water increases from 13 C to 24 C in the condenser.arrow_forwardSpace storage food requires system cooling capacity 15 ton refrigeration operates in the the temperature of the evaporator -17.5 °C and temperature condenser 42.5 °C. Refrigerant used is R-134a and the system operate on conditions saturated. Specify: a. COP b. The flow rate of the refrigerant = kg/s. c. The rate of heat loss in condenser = kJ/s.arrow_forwardSpace storage food requires system cooling capacity 15 ton refrigeration operates in the the temperature of the evaporator -17.5 °C and temperature condenser 42.5 °C. Refrigerant used is R-134a and the system operate on conditions saturated. Specify: a. COP (C.O.P is found using enthalpy) b. The flow rate of the refrigerant = kg/s. c. The rate of heat loss in condenser = kJ/s.arrow_forward
- 10. A system with flow rate of 18 gpm requires a motor to turn at 800 rpm. What size motor should be selected? Assume a volumetric efficiency of 95%. 11. Describe the difference hetween inline and suh plate mounting of budraulic avenarrow_forwardTime constant of thermocouple is 3 milliseconds. An engineer measures the temperature of water and sees that the temperature is less than the real temperature of the boiling water (100 C). How long does the engineer need to wait at least to see the 95 C? 8 milliseconds 5 milliseconds 3 milliseconds none of the given 9 milliseconds not sufficient informationarrow_forwardThe system shown below is to be designed for the gathering of gas. Well "A" is a following gas that will deliver 94.17 10' m'. The well "B" contains high gas-oil ratio wells, it is necessary to know that the compressor discharge pressure is 2.65 Mpa in order to deliver 61.09*10' m'. The pressure at the transmission line point is 2.07 Mpa gauge. Average following temperature will be (122 -158 °), compressibility factor (0.915-0.983), and that specific gravity of the following gas 0.69 and that of the other gas well is 0.71. The pressures at point "A and D" are 2.86, and 2.47 Mpa respectively. Estimate efficiency and the unknown values on figure. AL-? D-11.15 cm L-16.1 km D-? D B L= (4.83 – 9.2) km D= 10.24 em Note: 1- Each Student using different value of temperature and compressibility factor by taking as. Like: Temperature (123.23 ") and compressibility factor 0.933 2- Any similarity in solution student grade equal zero.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
![Text book image](https://www.bartleby.com/isbn_cover_images/9780190698614/9780190698614_smallCoverImage.gif)
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
![Text book image](https://www.bartleby.com/isbn_cover_images/9780134319650/9780134319650_smallCoverImage.gif)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
![Text book image](https://www.bartleby.com/isbn_cover_images/9781259822674/9781259822674_smallCoverImage.gif)
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
![Text book image](https://www.bartleby.com/isbn_cover_images/9781118170519/9781118170519_smallCoverImage.gif)
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
![Text book image](https://www.bartleby.com/isbn_cover_images/9781337093347/9781337093347_smallCoverImage.gif)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781118807330/9781118807330_smallCoverImage.gif)
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY