The two primary windings of a dual-primary control transformer (240 V or 480 V) are to be connected in parallel to step the line voltage of 240 V down to a control voltage of 120 V. Assuming the two primary windings are incorrectly connected in series instead of parallel what effect would this have on the control circuit?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The circuit for a 20-kVA, 220/3960 V, 50-Hz transformer is shown in Figure (1). The open-
circuit test and the short-circuit test was performed on this transformer and the following
data were taken:
Open-Circuit test: Voc=240 V, Ioc=2.8 A, Poc=260 W
Short-Circuit test: Vsc = 350 V, Isc=7.6 A, Psc = 420 W
1) Find the values of Rc, XM, Rp and Xs for this transformer.
2) Find the equivalent circuit of this transformer referred to the high-voltage side and draw
the circuit.
j 0.163 Q
jXM
0.02 02
jXs
An 11 kV, 25 Hz transformer has 12R, hysteresis and eddy current losses 1.5, 0.6 and 0.4 percent of the output. What will be the percentage losses if the transformer is connected to 22 kV, 50 Hz supply assuming the full load current to remain the same ?
During short-circuit test of a transformer, which winding must be short-circuited? Why?
Chapter 3 Solutions
Connect 1 Semester Access Card For Electric Motors And Control Systems
Ch. 3.1 - Prob. 1RQCh. 3.1 - a. If 1 MW of electric power is to be transmitted...Ch. 3.1 - Compare the type of AC power normally supplied to...Ch. 3.1 - a. Outline the basic function of a unit...Ch. 3.1 - list three factors taken into account in selecting...Ch. 3.1 - When motors and motor controllers are installed,...Ch. 3.1 - a. What types of conduit raceways are commonly...Ch. 3.1 - Compare the function of a switchboard, panelboard,...Ch. 3.2 - Define the terms primary and secondary as they...Ch. 3.2 - On what basis is a transformer classified as being...
Ch. 3.2 - Explain how the transfer of energy takes place in...Ch. 3.2 - In an ideal transformer, what is the relationship...Ch. 3.2 - A step-down transformer with a Wins ratio of 10:1...Ch. 3.2 - A step-up transformer has a primary current of 32...Ch. 3.2 - What is meant by the term transformer magnetizing,...Ch. 3.2 - Prob. 8RQCh. 3.2 - Prob. 9RQCh. 3.2 - Prob. 10RQCh. 3.2 - The primary of a transformer is rated for 480 V...Ch. 3.2 - A single-phase transformer is rated for 0.5 kVA, a...Ch. 3.3 - Explain the way in which the high-voltage and...Ch. 3.3 - Prob. 2RQCh. 3.3 - Prob. 3RQCh. 3.3 - Prob. 4RQCh. 3.3 - Prob. 5RQCh. 3.3 - Prob. 6RQCh. 3.3 - Prob. 7RQCh. 3.3 - Prob. 8RQCh. 3.3 - Explain the basic difference between the primary...Ch. 3.3 - Prob. 10RQCh. 3.3 - Prob. 11RQCh. 3.3 - Prob. 12RQCh. 3.3 - What important safety precaution should be...Ch. 3.3 - Prob. 14RQCh. 3.3 - The control transformer for an across-the-line...Ch. 3.3 - The two primary windings of a dual-primary control...Ch. 3.3 - Prob. 3TCh. 3.3 - A dry-type general-purpose power transformer is...Ch. 3.3 - A current transformer is to be tested in circuit...Ch. 3.3 - Discuss how electric power might be distributed...Ch. 3.3 - A block of several transformers arc fed from...Ch. 3.3 - How would you proceed with a DC resistance check...Ch. 3.3 - Prob. 5DT
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
How is the hydrodynamic entry length defined for flow in a pipe? Is the entry length longer in laminar or turbu...
Fluid Mechanics Fundamentals And Applications
Select a mechanical component from Part 3 of this book (roller bearings, springs, etc.), go to the Internet, an...
Shigley's Mechanical Engineering Design (McGraw-Hill Series in Mechanical Engineering)
Assume the following vectors are already defined: V1=[302]V2=[214]V3=[5131]V4=[0.50.10.20.2] For each of the fo...
Thinking Like an Engineer: An Active Learning Approach (4th Edition)
A biological fluid moves at a flow rate of m=0.02kg/s through a coiled, thin-walled, 5-mm-diameter tube submerg...
Fundamentals of Heat and Mass Transfer
Compute the hydraulic radius for a circular drain pipe running half full if its inside diameter is 300 mm.
Applied Fluid Mechanics (7th Edition)
3.3 It is known that a vertical force of 200 lb is required to remove the nail at C from the board. As the nail...
Vector Mechanics for Engineers: Statics, 11th Edition
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Flag this question for future reference What is the test that can be conducted in the laboratory to understand the transformer impedance drops are dependent on the load current with a variation in the secondary voltage? O a. Direct Load Test O b. Open Circuit Test OC. Voltage Ratio Test O d. Polarity Testarrow_forwardA short circuit test is applied to a 5-kVA, 220/110 volts single phase transformer. The input voltage applied to the high side is 50 volts until rated current is achieved. The power measured at this test is 350 watts. Determine: a. the equivalent resistance b. the equivalent reactancearrow_forward1- The resistance of secondary windings of step-down transformer is resistance of secondary windings. 2- In case wave winding, the parallel path of armature equal to 3- The magnetic and mechanical losses known as 4- Best connection of 3-ph transformers winding is than when use as step- down transformers. 5- The DC generators were classified according filed winding connection toarrow_forward
- What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected to a 500 Hz (frequency) source of the same voltage? Current will be too much high a. b. Transformer may start to smoke and burn Eddy Current and Hysteresis loss will be excessive c. d. No effectarrow_forwardDraw and label the equivalent circuit for a transformer. Explain the principles of operation behind a transformer. How are the effects of eddy currents minimised?arrow_forwardA 2300/208-V 500-kVA 60-Hz single-phase transformer was tested by means of the open-circuit test (on the low-voltage winding) and short-circuit test (on the high-voltage winding). The test data obtained are: Open-circuit test: Voc = 208 V, Ioc = 52.5 A, Short-circuit test: Vsc = 95 V, Poc = 3800 W Psc = 6200 W ос %3D ос Isc = 217.4 A, %3D %3D Calculate a. the efficiency of the transformer at rated kVA and half-rated kVA, when the power factor is 0.866 lagging; andarrow_forward
- (Question 2): Answer the following questions: 1. The equivalent circuit impedances of a 20-kVA, 800CV240-V, 60-Hz transformer are to be determined. The open-circuit test and the short-circuit test were performed on the primary side of the transformer, and the following data were taken: Open circuit test (on primary) Short circuit test (on primary) VDC=8000V VS.c=489V IDC=0.214 ISc=2.5A PDC=400W PS.C=240W Find the impedances of the approximate equivalent circuit referred to the primary side, and sketch that circuit. 2. Based on the following Simulink model, answer the following questions: Continu pover Geet Gebe Rator p n Lea N) Ceongre tre ma Main Aaitay wengs Curet nent Mean nuoed Torge N nuneng reA votag eaen+ wineng A Singe Pa Anonenous ne Spe samgcapacter Froms Le votag Lne Curet From? (a) For which type of single phase induction motors does this circuit represent? (b) Explain the purpose of C1 in induction motors? (c) How to reverse the direction of rotation of this motor ? (d)…arrow_forwardThe primary winding of a transformer connected to 2,200 volts circuit consists of two coils which may be connected in series or in parallel. When they are in series, with secondary circuit open the primary current is 0.32 amp and the power input is 150 watts. Calculate the no load current and power factor when the primary coils are connected in parallel on a 1,000- volt circuit of the same frequency.arrow_forward8.a. The type of coil usually used in power transformers rated at less than 15,000 volts is theA. shell-form coil.B. core-form coil.C. disk coil.D. cylindrical coil.8.b. In large power transformers, the unequal voltage distribution caused by voltage surges in the winding isprevented by the use ofA. series capacitors.B. parallel inductances.C. static shields.D. low-voltage arresters.arrow_forward
- 6. A 50-kVA, 2400/240-volt, 60HZ single - phase transformer is supplied with power directly from a large constant-voltage bus. In the short-circuit test, the recorded values on the high-voltage side (with low-voltage winding shorted) are: Vsc = 52 V Isc = 20.8 A Psc = 650 W Find Reg and Xeq referred to the low voltage side of the transformer.arrow_forwardThree 60-VA, 120/208-V, single-phase transformers are to be used to form a three-phase transformer. For each of the four connections. Determine: (a) phase voltages, (b) phase currents, (c) a-ratio (d) power rating.arrow_forwardElectrical Engineering AC input= 120V rms. Transformer Ratio = 15:1. Reference Voltage = 6.3V. R load = 56 Ohms. Ambient temperature (TA) = 25 degrees C. Vpeak 2N3904 Transistor Regulated Output Rload AC Input Reference Voltage How much power is dissipated by the transistor? How much current is flowing in the transformer primary winding?. Of the regulator types discussed in class, what type of regulator is this? (be specifi HE Leeetarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,
Understanding Conduction and the Heat Equation; Author: The Efficient Engineer;https://www.youtube.com/watch?v=6jQsLAqrZGQ;License: Standard youtube license