Liquidtight flexible metal conduit may serve as a grounding means in sizes up to and including _______ in. where used with listed fittings.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Are double locknuts an acceptable bonding method for Class 1, Division 1 Hazardous locations?
If not, list an acceptable method, backing up your answer with a code citation.
In the conduit layout shown in picture attached, determine how many wires are contained in each conduit between each piece of equipment. Identify each wire with a proper terminal marking, as shown in the example, above the disconnect switch.
In the conduit diagram shown in attached picture, determine how many wires are in each conduit between each piece of equipment. Identify each wire terminal connection and the quantity of wires, as shown in the example, above the disconnect
Chapter 4 Solutions
Electrical Wiring Residential
Ch. 4 - The largest size solid conductor generally...Ch. 4 - What is the minimum branch-circuit wire size that...Ch. 4 - What exceptions, if any, are there to the answer...Ch. 4 - What determines the ampacity of a wire?Ch. 4 - What unit of measurement is used for the diameter...Ch. 4 - What unit of measurement is used for the...Ch. 4 - What is the voltage rating of the conductors in...Ch. 4 - Indicate the allowable ampacity of the following...Ch. 4 - Prob. 9RCh. 4 - What are the colors of the conductors in...
Ch. 4 - For nonmetallic-sheathed cable, may the...Ch. 4 - Prob. 12RCh. 4 - Under what condition may nonmetallic-sheathed...Ch. 4 - a. What is the maximum distance permitted between...Ch. 4 - Prob. 15RCh. 4 - Prob. 16RCh. 4 - Prob. 17RCh. 4 - Prob. 18RCh. 4 - Prob. 19RCh. 4 - Circle the correct answer to the following...Ch. 4 - When running Type NM cable through a bored hole in...Ch. 4 - Where is the main service-entrance panel located...Ch. 4 - Is it permitted to use flexible metal conduit over...Ch. 4 - Liquidtight flexible metal conduit may serve as a...Ch. 4 - It is permissible for an electrician to connect...Ch. 4 - Terminals of switches and receptacles marked...Ch. 4 - Wire connectors marked AL/CU are suitable for use...Ch. 4 - A wire connector bearing no marking or reference...Ch. 4 - When Type NM cable is run through a floor, it must...Ch. 4 - When nonmetallic-sheathed cables are bunched or...Ch. 4 - In diagrams A and B, nonmetallic-sheathed cable is...Ch. 4 - The marking on the outer jacket of a...Ch. 4 - A 120-volt branch circuit supplies a resistive...Ch. 4 - In problem 35, it is desired to keep the voltage...Ch. 4 - Prob. 37RCh. 4 - The allowable ampacity of a 4 AWG THHN from Table...Ch. 4 - If, because of some obstruction in a wall space,...Ch. 4 - The recessed fluorescent luminaires installed in...Ch. 4 - Prob. 41RCh. 4 - What size overcurrent device protects the...Ch. 4 - May the 20-ampere small-appliance branch circuits...Ch. 4 - A 30-ampere branch circuit is installed for an...Ch. 4 - In many areas, metal framing members are being...Ch. 4 - Are set screwtype connectors permitted to be used...Ch. 4 - Most armored cable today has 90C conductors. What...Ch. 4 - If you saw two different types of SE cables, how...Ch. 4 - Circle the correct answer defining the type of...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
Does the severity of an electric shock increase ordecrease with eh of the following changes? a. A decrease in t...
Electric Motors and Control Systems
How many coulombs do 93.8 1016 electrons represent?
Principles Of Electric Circuits
Electric power systems provide energy in a variety of commercial and industrial settings. Make a list of system...
Principles and Applications of Electrical Engineering
Identify the type of input and output configuration for each diff-amp in Figure 18-35.
Electronics Fundamentals: Circuits, Devices & Applications
The current source in the circuit shown generates the current pulse
Find (a) v (0); (b) the instant of time gr...
Electric Circuits. (11th Edition)
A constant voltage of 10V is applied to a 50H inductance, as shown in Figure P3.51 Figure P3 51 The current in ...
Electrical Engineering: Principles & Applications (7th Edition)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Is it permitted to use flexible metal conduit over 6 ft (1.8 m) in length as a grounding means? (Yes) (No) (Circle the correct answer.)arrow_forward6. Which of the following is a condition that a liquidtight flexible metal conduit must meet in order to be suitable as an equipment grounding conductor? A. The conduit is terminated in listed fittings.B. For trade sizes 3/4 through 1 1/4, the conduit conductors contained in the conduit are protected by overcurrent devices rated at 20 amperes or less.C. The combined length of the conduit and other tubing and conduit in the same ground-fault path exceeds six feet. D. For trade sides 3/8 through 1/2, the circuit conductors contained in the conduit are protected by overcurrent devices rated not more than 60 amperes. 7. You're going to connect a surge protection device to a separately derived electrical system. In this situation, the surge protection device should be connected at A. the load side of the first overcurrent protection device. B. the input to the transformer's primary winding.C. the end of the shortest branch circuit.D. the first connected IT cabinet. 8. What is another term…arrow_forwardIdentify and explain the safety procedures and precautions when working with tools and equipment’s that should be followed during the installation of the cables?arrow_forward
- Flexible metal conduit (FMC) shall be securely fastened in place by an approved means within ____ of each box, cabinet, conduit body, or other conduit termination and shall be supported and secured at intervals not to exceed ____. Select one: a. 6 in., 2 ft, b. 6 in., 3 ft, c. 8 in., 4 1/2 ft, d. 12 in., 4 1/2 ft,arrow_forward4 Describe the various methods of laying underground cables. What are the relative advantages anddisadvantages of each method?arrow_forward18. Which of the following would help avoid the choke effect in grounding electrode conductors?A. Installing a main bonding jumperB. Using an approved polyvinyl chloride conduitC. Applying solder to the connectionD. Using bonding bushes on the ends of the racewayarrow_forward
- Which section of the Code prohibits supporting coaxial cables from raceways that contain light or power conductors? NEC ______________arrow_forwardDoes the NEC allow metal raceways to be used with nonmetallic boxes? Yes __________ No __________, NEC __________arrow_forwardList the methods by which an equipment grounding conductor is connected to a device box.arrow_forward
- A Type NM cable carries a branch circuit to the outside of a building, where it terminates in a metal weatherproof junction box. From this box, a short length of EMT is installed upward to another metal weatherproof junction box on which is attached a cluster of outdoor floodlights. The first box is located approximately 24 in. (600 mm) above the ground. To Meet Code, do the metal boxes and metal raceway have to be grounded? Yes _______________ No _______________ NEC _______________.arrow_forwarda. How is EMT fastened to masonry? _______________ _______________ b. The cut ends of rigid and electrical metallic tubing must be ______________ to prevent the insulation on conductors from being damaged.arrow_forwardIt is generally understood that grounding and bonding together all metal parts of an electrical system and the metal shield of the cable television cable to the same grounding reference point in a residence will keep both systems at the same voltage level should a surge, such as lightning, occur. Therefore, if the incoming cable that has been installed by the CATV cable company installer has the metal shield grounded to a driven ground rod, does this installation conform to the NEC? ___________arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License