Question
Chapter 47, Problem 10RQ
To determine
The conductor size, overload size, fuse size, minimum NEMA and IEC starter sizes and the upper and the lower range for starting the current for the given motor.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A 3 kVA motor operates from a 240 V
supply at 50 Hz and has a power
factor of 0.6. Determine the active
power
Select one:
1800 W
Non of the Answers
1900 W
2000 W
al
Three coils each having resistance of 29 N are connected in star across 422 V, 50 Hz supply. Then the total
power consumed is
O 211.77 W
O 3545.51 W
O 730.95 W
O 6140.83 W
Question 4
A 228 V/ 111 V single-phase transformer has a core loss of 110 W and the no-load current is 0.7 A. The no load power factor is
Not yet
answered
Marked out of
O 0.99
1.00
O 1.42
P Flag question
O 0.48
O 0.69
Question 5
A 2 kV / 229 V transformer has the secondary turns of 47. The number of Primary turns of a transformer is given by,
Not yet
answered
63.83
Marked out of
410.48
1.00
O 615.72
P Flag question
O 5381.50
Question 6
For the given power transfer, a delta system is associated with larger line currents and a star system is associated with a larger line voltage.
Not yet
answered
Select one:
Marked out of
O True
1.00
P Flag question
O False
Chapter 47 Solutions
EBK 3N3-EBK: INDUSTRIAL MOTOR CONTROL
Knowledge Booster
Similar questions
- Two transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forwardA 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forwardA 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forward
- How does the National Electrical Code specify that the high leg of a four-wire delta connection be marked?arrow_forwardThe working current has a power of 100 kW and a power factor of 0.50. After a capacitor of 75 KVAR is installed, what does the power factor become? A 0.84 B 0.71 C 0.63 D 0.78 E 0.92arrow_forwardIf dual-element time delay fuses are to be used as the short circuit protective device, what size fuses should be used to protect the circuit in question #12? Five 5 HP, three-phase motors with NEMA code B are connected to a 240-volt line. The conductors are copper with type THWN insulation. What size conductor should be used to supply all of these motors?arrow_forward
- Refer to the transformer shown in Figure 5-13 to answer the following questions. What is the turns ratio of the winding between points B and E as compared to the winding between points D and E? Figure 5-13 Autotransformer practice problems.arrow_forwardThe following data were obtained on a 50 kVA 2400/120 V transformer: Open circuit test, instruments on low voltage side: Waltmeter reading = 396 Watts Ammeter reading = 9.65 amperes Voltmeter reading = 120 Volts Short circuit test, instruments on high voltage side: Waltmeter reading = 810 Watts Ammeter reading = 20.8 amperes Voltmeter reading = 92 Volts Find the efficiency when rated kVA is delivered to a load having a power factor of 0.8 lagging.The following data were obtained on a 50 kVA 2400/120 V transformer : Open circuit test, instruments on low voltage side: Waltmeter reading = 396 Watts Ammeter reading = 9.65 amperes Voltmeter reading = 120 Volts Short circuit test, instruments on high voltage side: Waltmeter reading = 810 Watts Ammeter reading = 20.8 amperes Voltmeter reading = 92 Volts Find the efficiency when rated kVA is delivered to a load having a power factor of 0.8 lagging.arrow_forwardA transformer has a primary voltage of 480 volts and a secondary voltage of 20 volts. What is the turns ratio of the transformer?arrow_forward
- How many transformers are needed to make an open-delta connection?arrow_forwardRefer to the transformer shown in Figure 5-13 to answer the following questions. The transformer shown in Figure 5-13 is supplying 325 volt amperes to a load. The primary voltage is 240 volts. What is the primary current? Figure 5-13 Autotransformer practice problems.arrow_forwardName three factors that determine the amount of induced voltage.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning