Industrial Motor Control
7th Edition
ISBN: 9781133691808
Author: Stephen Herman
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 47, Problem 12RQ
To determine
The size of the conductor that should be used to supply all the motors when the 5 horsepower, three phase motor with the NEMA code B is connected to the 240 V line, the conductor are copper with type THWN insulation.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionChapter 47 Solutions
Industrial Motor Control
Knowledge Booster
Similar questions
- A large motor has a full load current rating of 425 amperes. Current transformers with a ratio of 600:5 are used to reduce the current to the overload heaters. What should be the full load current rating of the overload heaters?arrow_forwardTwo transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forwardIf dual-element time delay fuses are to be used as the short circuit protective device, what size fuses should be used to protect the circuit in question #12? Five 5 HP, three-phase motors with NEMA code B are connected to a 240-volt line. The conductors are copper with type THWN insulation. What size conductor should be used to supply all of these motors?arrow_forward
- What is the full-load running current of a three-phase, 50-hp motor connected to a 560-volt line? What are the minimum size NEMA and IEC starters that should be used to connect this motor to the line?arrow_forwardA 125-hp synchronous motor is connected to a 230-volt three-phase AC line. The motor is intended to operate at 80% power factor. What is the full-load running current of this motor? What are the minimum size NEMA and IEC starters that should be used to connect this motor to the line?arrow_forwardAn AC power source is connected across 325 turns of an autotransformer, and the load is connected across 260 turns. What is the turns ratio of this transformer?arrow_forward
- To what is the voltage regulation of a DC generator proportional?arrow_forwardA 125 HP, synchronous motor is connected to a 230-volt, three phase AC line. The motor is intended to operate at 80 percent power factor. What is the full load running current of this motor? What is the minimum size NEMA and IEC starters that should be used to connect this motor to the line?arrow_forwardA three-phase squirrel-cage motor is connected to a 60-Hz line. The full-load speed is 870 RPM. How many poles per phase does the stator have?arrow_forward
- A 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forwardA ¾ HP, single-phase squirrel cage motor is connected to 240-volt AC line. What is the full load current rating of this motor and what is the minimum size NEMA and IEC starters that should be used?arrow_forwardA 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning