Textbook Question
Chapter 8, Problem 8.37P
The thermocouple circuit shown in Figure 8.49 measures the temperature Tj. The voltmeter limits of error are given as
Figure 8.49 Thermocouple circuit for Problem 8.37.
Limits of error: ±0.05% (95%) of reading +15 pV at 25°C
Resolution: 5 pV
Give a best estimate for the temperature T\, if the output voltage is 9 mV.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A thermocouple has an output emf as shown in the following table when its hot (measuring) junction is at the temperatures shown. Determine the sensitivity of measurement for the thermocouple in mv/"C. Temperature (C) 3.5 13
4 12
Voltage imv)
Sensitivity, S
. thermodynamics-
A platinum resistance thermometer has a resistance of 5 ohm at 0°C and 2.5 ohm at 100°C Calculate the temperature when the resistance indicated is 10 ohm.
A load cell is calibrated in an environment at a temperature of 21°C and has the following deflcction/load characteristic:
Load (kg) 0 50 100 150 200
Deflection (mm) 0.0 1.0 2.0 3.0 4.0
When used in an environment at 35°C, its characteristic changes to the following:
Load (kg) 0 50 100 150 200
Deflection (mm) 0.2 1.3 2.4 3.5 4.6
Determine the sensitivity at 21°C and 35°C.
Calculate the total zero drift and sensitivity drift at 35°C.
Hence determine the zero drift and sensitivity drift coefficients (in units of pm/°C and (pm per kg)/(°C)).
Chapter 8 Solutions
Theory and Design for Mechanical Measurements
Ch. 8 - Prob. 8.1PCh. 8 - Fixed temperature points in the International...Ch. 8 - Answers to the following questions may be found in...Ch. 8 - Calculate the resistance of a platinum wire that...Ch. 8 - Plot the resistance of a platinum wire that is 5 m...Ch. 8 - An RTD forms one arm of a Wheatstone bridge, as...Ch. 8 - An RTD forms one arm (/?4) of a Wheatstone bridge,...Ch. 8 - Research and describe current state-of-the-art...Ch. 8 - Prob. 8.9PCh. 8 - 8.10 Estimate the required level of uncertainty in...
Ch. 8 - 8.11 A thermistor is placed in a 100 °C...Ch. 8 - Prob. 8.12PCh. 8 - Prob. 8.13PCh. 8 - The thermocouple circuit in Figure 8.45 represents...Ch. 8 - The thermocouple circuit in Figure 8.45 represents...Ch. 8 - The thermocouple circuit in Figure 8.45 is...Ch. 8 - 8.17 a. The thermocouple shown in Figure 8.46a...Ch. 8 - Prob. 8.18PCh. 8 - Prob. 8.19PCh. 8 - A temperature measurement requires an uncertainty...Ch. 8 - A temperature difference of 3.0 °C is measured...Ch. 8 - Complete the following table for a J-type...Ch. 8 - Complete the following table for a T-type...Ch. 8 - Prob. 8.24PCh. 8 - 8.25 You are employed as a heating, ventilating,...Ch. 8 - A J-type thermocouple for use at temperatures...Ch. 8 - A J-type thermocouple is calibrated against an RTD...Ch. 8 - A beaded thermocouple is placed in a duct in a...Ch. 8 - Consider a welded thermocouple bead that...Ch. 8 - Prob. 8.30PCh. 8 - Prob. 8.31PCh. 8 - Consider the typical construction of a sheathed...Ch. 8 - An iron-constantan thermocouple is placed in a...Ch. 8 - Figure 8.48 Schematic diagram for Problems 8.33,...Ch. 8 - Figure 8.48 Schematic diagram for Problems 8.33,...Ch. 8 - 8.36 In Example 8.5, an uncertainty value for Rf...Ch. 8 - The thermocouple circuit shown in Figure 8.49...Ch. 8 - Prob. 8.38PCh. 8 - 8.39 A thin-film heat flux sensor employs a K-type...Ch. 8 - A thin-film heat flux sensor has a sensitivity uV...Ch. 8 - 8.41 A T-type thermopile is used to measure...Ch. 8 - 8.42 A T-type thermocouple referenced to 0 °C is...Ch. 8 - A T-type thermocouple referenced to 0 °C develops...Ch. 8 - 8.44 A temperature measurement system consists of...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The transducer specified in Table 1.1 is chosen to measurea nominal pressure of 500 cm H2O. The ambient temperature is expected to vary between 18 ∘C and 25 ∘C duringtests. Estimate the possible range (magnitude) of each listedelemental error affecting the measured pressure. How do I calculate the sensitivity error? The solution that was given: Sensitivity error(eK) = (±0.0025)(500 cm H2O)= ± 0.75 cm H2O = ± 0.00375 V My Question is, how do you obtain 0.75 since 0.0025 x 500 gives 1.25! please help. thanksarrow_forwardThe following resistance of a platinum resistance thermometer were measured at a range of temperature. Determine the measurement sensitivity of the instrument in milli Ohms/ oC. Resistance (mῼ) Tempreture (oC) 210k 110 217k 89 221k 68 228k 47arrow_forwardExplain the significance of the following information given in the specification of the followingtransducer,Thermocouple Sensitivity: nickel chromium/nickel aluminum thermocouple: 0.039 mV/ºC when thecold junction is at 0 ºC.arrow_forward
- Use appropriate diagram and sketches. When the cold junction of a thermocouple thermometer is at 0° C and the hot junction at 100°C the millivoltmeter shows a deflection of 4.2 mV towards the left. The cold junction is now put in an unknown temperature while maintaining the hot junction at 100°C. The millivoltmeter now shows a deflection of 5.2 mV towards the right. Calculate the unknown temperaturearrow_forwardThe transducer specified in Table 1.1 is chosen to measurea nominal pressure of 500 cm H2O. The ambient temperature is expected to vary between 18 ∘C and 25 ∘C duringtests. Estimate the possible range (magnitude) of each listedelemental error affecting the measured pressure refering to the solution provided online, Sensitivity error(eK) = (±0.0025)(500 cm H2O)= ± 0.75 cm H2O = ± 0.00375 V how do you get 0.75?? shoud it not be 1.25? according the answer, for sensitivityarrow_forwardA chromel-constantan type thermocouple has a cold junction (or cold terminal) at the temperature of 20ºC. The tables provide the following values for this thermocouple: 0°C for e.m.f = 0.000 mV; 20ºC for e.m.f = 1192 mV and 200ºC for e.m.f = 13419 mV. To determine:(a) The Seebeck coefficient (or proportionality constant) of this thermocouple. (b) The electrical voltage at the thermocouple terminals when the hot junction (or terminal hot) is at a temperature of 200ºC.arrow_forward
- A temperature measurement system is composed of a sensor and a readout device. The readout device has a claimed accuracy of 0.6 °C with a resolution of 0.1 °C. The sensor has an off-the-shelf limit of error of 0.5 °C. Estimate a design-stage uncertainty in the temperature indicated by this combination. A displacement transducer has the following specifications: Linearity error:±0.25% reading Drift:±0.05%/°C reading Sensitivity error: ±0.25% reading Excitation: 10-25 V Output: dc 0-5Vdc Range: 0-5 cm The transducer output is to be indicated on a voltme- ter having a stated accuracy of 0:1% reading with a resolution of 10 μV. The system is to be used at room temperature, which can vary by 10 °C. Estimate an uncertainty in a nominal displacement of 2 cm at the design stage. Assume 95% confidence.arrow_forwardA thermometer is calibrated from 200degree centigrade to 300degree. the accuracy is specified as +-0.25%. Non Linearity is +-0.5% Hystersis is +-0.01% what is the maximum errorarrow_forwardConsider a cylindrical cross‐section pipe that is 50 m long with a 7 cm diameter, and which has a starting pressure of 320 kPa and an outlet pressure of 105 kPa. A pressure sensor is located 10 m from the start of the pipe. (a) Calculate the pressure that this sensor would read if the fluid were water (ρ = 1000 kg/m3 ). (b) If the pipe instead contains gaseous carbon dioxide in isothermal flow, would the pressure be the same at this sensor as if the fluid were water?arrow_forward
- (Q4) A thermopile 18 constructed with Iron-constantan materials. Four junctions are maintained at 300°C and for junctions are maintained at 40°C. The output of the thermopile is connected to a potentiometer. What voltage will be indicated if both terminals of the potentiometer are at the same temperature? What is the temperature indicated in this case?arrow_forwardA probe with an improvement coefficient of 0.88 will measure the temperature in an ideal gas flow with a speed of 95 m/s. Since the gas constant of the liquid is 0.288 kJ/kgK and its isanthropic base is 1.4, how many ºC is the difference between the temperature that the probe will show and the actual temperature of the liquid? a. 2.317 b. 3.939 c. 2.455 d. 2.716 e. 3.268arrow_forwardIn the measurement with the thermoeleman circuit, whose voltage-temperature relation is linear and the calibration coefficient is 0.05 mV/ºC, it was understood that the temperature of the reference end is higher than 0ºC after the measurement point temperature is calculated as 80ºC. To resolve this error, this time the measuring tip was immersed in the water-ice mixture and a deviation of 0.15 mV was observed at the millivolt meter. How many ° C is the first value measured as 80 ° C? a. 76.25 b. 77.50 c. 78.00 d. 75.00 e. 77.00arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Heat Transfer – Conduction, Convection and Radiation; Author: NG Science;https://www.youtube.com/watch?v=Me60Ti0E_rY;License: Standard youtube license