Textbook Question
Chapter 39, Problem 7RQ
A PLC requires that times be programmed in 0.1-second intervals. What number should be entered to produce a time delay of 3 minutes?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
An emergency stop system is to be designed for a certain automatic production machine. A single “start” button is used to turn on the power to the machine at the beginning of the day. In addition, there are two “stop” buttons located at two locations on the machine, either of which can be pressed to immediately turn off power to the machine. Let X1 = start button (normally open), X2 = stop button 1 (normally closed), X3 = stop button 2 (normally closed), and Y = power-to-machine. (a) Construct the truth table for this system. (b) Write the Boolean logic expression for the system. (c) Construct the ladder logic diagram for the system
I want you to draw a ladder logic diagram of a garage door to control it by PLC. In my case we have different inputs and outputs and all of them gotta be used in the diagram. I can perfectly interpret the diagram so no need to explain it, I will just require you to draw it.
INPUTS : open push button ( OPB ) - close push button ( CPB ) - open limit switch ( OLS ) - close limit switch ( CLS ) - obstacle detection sensor ( ODS ) - safety sensor ( SS ) - emergency stop push button ( ESPB ) - reset button ( RB )
OUTPUTS : motor starts ( MS ) - motor stops ( MSTP ) - motor forward ( MF ) - motor reverse ( MR ) - Error display ( ER )
OPERATİNG MODES : automatic mode ( AM ) - manual mode ( MM )
NECESSARY TIMERS : T1 ( delay door movement after obstacle detection ) - T2 ( delay door movement after reversing )
Here is my excercise for today. Please I am requiring a good logic diagram taking into consideration all what was mentioned before.
so to sum up, I want you to write a logic ladder diagram…
2) The continuous stopwatch timing method was used to obtain the observed times for a
worker-machine task. Only one cycle was timed. The data are recorded in the table below.
The times are listed indicate the stopwatch reading at the end of the element. Elements
a, b, and d are worker-controlled elements. Element c is machine controlled. Elements a
and d are external to the machine-controlled element, while element b is internal. Every
four cycles, there is an irregular worker element that takes 1.32 min rated at 100%
performance. For determining the standard time, the PFD allowance is 15% and the
machine allowance is 30%. Determine
a. The normal time
b. Standard time for the cycle
c. If worker efficiency is 100%, how many units will be produced in one 8-hour shift?
d. If the actual time worked during the shift is 6.86 hours, and the worker
performance is 125%, how many units will be produced?
Description of
Worker
Time
Description of
(min) Rating (%) Element Machine Element
Worker…
Chapter 39 Solutions
Bundle: Understanding Motor Controls, 4th + Mindtap Electrical, 2 Terms (12 Months) Printed Access Card
Ch. 39 - Why are NEMA symbols such as push buttons, float...Ch. 39 - Prob. 2RQCh. 39 - Why are normally closed components such as STOP...Ch. 39 - Prob. 4RQCh. 39 - Prob. 5RQCh. 39 - List four basic rules for developing a program for...Ch. 39 - A PLC requires that times be programmed in...Ch. 39 - When programming in Boolean, what statement should...Ch. 39 - When programming in Boolean, what statement should...Ch. 39 - In a control circuit, it is imperative that a coil...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Circuit Problem and Description: Using the given components, design a pneumatic circuit which will correctly and safely operate this machine control application. This is a simple two- cylinder sequence (A and B), as follow; A+ B+ A- B-. This is known as a simple sequence when the order for the cylinder to move out is the same as for cylinder to move back. The start-up signal will be by means of a normally closed 3/2 way valve operated by push button (M1) or normally closed 3/2 way valve operated by switch (M2). Full extension and retraction of each cylinder can be monitored by four normally closed 3/2 way valve operated by roller (M3-M6). Extension and retraction speeds of both cylinders must be adjustable using 2 sets of 2 single-direction flow regulation valves. Materials: Component Description Part # SAI 2026 Double acting cylinder SAI 2015 Normally closed 3/2 way valve operated by push button SAI 2016 Normally closed 3/2 way valve operated by switch SAI 2013 Normally closed 3/2 way…arrow_forwardAn emergency stop system is to be designed for a certain automatic production machine. A single "start" button is used to turn on the power to the machine at the beginning of the day. In addition, there are three "stop" buttons located at different locations around the machine, any one of which can be pressed to immediately turn off power to the machine. (a) Write the truth table for this system. (b) Write the Boolean logic expression for the system. (c) Construct the logic network diagram for the system. (d) Construct the ladder logic diagram for the systemarrow_forward17- The memory unit of PLC is used to write the program to control output device. Select one: True Falsearrow_forward
- Traffic Light System Construct a PLC program for a traffic light system with the following condition: The green light will be ON for 10 second, followed by the yellow light for 3 second and red light for 20. The system will run continuously until the START/STOP switch is deactivated. Figure 12: The traffic light system Two Directional Control of Traffic Light Extend the PLC program for the traffic light system with the following condition:. Red = north/south Green = north/south Amber = north/south Green = east/west Amber = east/west Red = east/west -25 s ·5 s 25 s 5 sarrow_forwardWhat is a modal code?arrow_forwardSupposing a programmer, using absolute mode, mistakenly entered Z-3.689, when he or she intended to enter Z3.689. Describe what would happen, and how far the actual position would be from the intended position.arrow_forward
- 5. You need to know the resolution of the control. How many counts are there for 1 degree of motion?arrow_forwardExamine the following while loops and determine the value of ires at the end of each of the loops, and the number of times each loop executes. (a) ires - 1; while mod (ires, 21) = 0 iresires + 1; end ires = number of times ires= 2; while ires 100 iresires^2; end number of times (b) (c)arrow_forwardName the four basic sections of a programmable logic controller.arrow_forward
- Why are normally closed components such as STOP push buttons programmed normally open instead of normally closed when entering a program into the memory of a PLC?arrow_forwardName Section 5-2: Line Diagrams-Signals, Decisions, and Actions In the following application, a temperature switch controls a heating contactor and a flow switch is used to ensure there is enough air flow. If there is not enough air flow, an alarm is sounded. Complete the required information. 1. List all the signal devices in the circuit. 2. List all the action devices in the circuit. 3. List the decision part of the circuit that automatically sounds the alarm if there is a problem. 4. When the heating element is on during normal operation, is the flow switch open or closed? CIRCULATING 2 L1 FAN TEMPERATURE SWITCH TR HEATING ELEMENTS FLOW SWITCH -HOT AIR PADDLE AIR FILTER NORMALLY CLOSED FLOW SWITCH 65 ALARM (SOUNDS IF NO FLOW FOR 15 SECONDS OR MORE) Date HEATING CONTACTOR TR ON-DELAY TIMER SUPPLY AIR COLD AIR (3) TIME SET= 15 SEC © 2014 American Technical Publishers, Inc. All rights reservedarrow_forwardestion 1 The step resolution of a stepper motor is set for 1024 steps per revolution, Find the frequency to rotate at 60 rpm. (Give your answer in Hertz, put only numeric value) Question 3 A proportional valve is handled by an PWM signal Question 4 The speed of a stepper motor is controlled by Question 5 The relay is driven by an analog signal Question 6 Determine the output voltage from a PWM pin when the time ON is 25 ms and the frequency is 1kHz and Vcc-SV. (Put only a number in Volt, no need to add the unit word)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningPrecision Machining Technology (MindTap Course Li...Mechanical EngineeringISBN:9781285444543Author:Peter J. Hoffman, Eric S. Hopewell, Brian JanesPublisher:Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Precision Machining Technology (MindTap Course Li...
Mechanical Engineering
ISBN:9781285444543
Author:Peter J. Hoffman, Eric S. Hopewell, Brian Janes
Publisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
The Robot Revolution: The New Age of Manufacturing | Moving Upstream; Author: Wall Street Journal;https://www.youtube.com/watch?v=HX6M4QunVmA;License: Standard Youtube License